Accuracy of Implant Positioning in Total Hip Arthroplasty via a Supine Direct Anterior Approach Using Fluoroscopy

被引:0
作者
Kanno, Keijiro [1 ]
Hagiwara, Shigeo [1 ]
Shiko, Yuki [2 ]
Kawarai, Yuya [1 ]
Nakamura, Junichi [1 ]
Ohtori, Seiji [1 ]
机构
[1] Chiba Univ, Grad Sch Med, Dept Orthopaed Surg, 1-8-1 Inohana,Chuo Ku, Chiba 2608670, Japan
[2] Chiba Univ Hosp, Clin Res Ctr, Biostat Sect, 1-8-1 Inohana,Chuo Ku, Chiba 2608670, Japan
关键词
direct anterior approach; implant position; propensity score matching; total hip arthroplasty; ACETABULAR COMPONENT ORIENTATION; DISLOCATION; POSTERIOR; PLACEMENT; ALIGNMENT; SURGERY;
D O I
10.1155/aort/8892577
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Adequate implantation is important to avoid complications following total hip arthroplasty (THA). This study aimed to evaluate the accuracy and precision of implant placement in the direct anterior approach (DAA) using fluoroscopy in comparison with the anterolateral approach in lateral decubitus position (OCM) using a single implant.Methods: We retrospectively compared propensity score-matched THAs in DAA with fluoroscopy and in OCM. The achievement ratio of the Lewinnek cup safe zone, absolute difference in alignment, and positioning from preoperative planning was evaluated and compared between each approach.Results: 33 patients in both groups were eligible for this study. Significantly more cups were inside the safe zone in the DAA group than in the OCM group (33/33 vs. 25/33, p = 0.0048). No significant differences were found between the DAA group and OCM group regarding the discrepancy from the target cup inclination, anteversion, and three-dimensional positioning. No significant difference was noted in stem alignment; however, the equality of coronal alignment variances was smaller in the DAA group (p = 0.0047). No significant differences were found in the clinical score and complication rate.Conclusion: The DAA using fluoroscopy may provide more accuracy for cup placement and precision for stem placement than OCM.
引用
收藏
页数:8
相关论文
共 33 条
[1]   Current Practice Trends in Primary Hip and Knee Arthroplasties Among Members of the American Association of Hip and Knee Surgeons: A Long-Term Update [J].
Abdel, Matthew P. ;
Berry, Daniel J. .
JOURNAL OF ARTHROPLASTY, 2019, 34 (07) :S24-S27
[2]   Robots in orthopaedic surgery - Past, present, and future [J].
Bargar, William L. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (463) :31-36
[3]   Prospective Randomized Study of Direct Anterior vs Postero-Lateral Approach for Total Hip Arthroplasty [J].
Barrett, William P. ;
Turner, Shelly E. ;
Leopold, John P. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (09) :1634-1638
[4]   Utility of Intraoperative Fluoroscopic Positioning of Total Hip Arthroplasty Components Using a Posterior and Direct Anterior Approach [J].
Belyea, Christopher M. ;
Lansford, Jefferson L. ;
Yim, Duke G. .
MILITARY MEDICINE, 2022, 187 (1-2) :E11-E16
[5]   Anterolateral mini-incision hip replacement surgery -: A modified Watson-Jones approach [J].
Bertin, KC ;
Röttinger, H .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :248-255
[6]  
Biedermann R, 2005, J BONE JOINT SURG BR, V87B, P762, DOI 10.1302/0301-620X.87B6
[7]   The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[8]   Comparison of a mechanical acetabular alignment guide with computer placement of the socket [J].
DiGioia, AM ;
Jaramaz, B ;
Plakseychuk, AY ;
Moody, JE ;
Nikou, C ;
LaBarca, RS ;
Levison, TJ ;
Picard, F .
JOURNAL OF ARTHROPLASTY, 2002, 17 (03) :359-364
[9]   Accuracy of Component Positioning in 1980 Total Hip Arthroplasties: A Comparative Analysis by Surgical Technique and Mode of Guidance [J].
Domb, Benjamin G. ;
Redmond, John M. ;
Louis, Steven S. ;
Alden, Kris J. ;
Daley, Robert J. ;
LaReau, Justin M. ;
Petrakos, Alexandra E. ;
Gui, Chengcheng ;
Suarez-Ahedo, Carlos .
JOURNAL OF ARTHROPLASTY, 2015, 30 (12) :2208-2218
[10]   Comparison of Robotic-assisted and Conventional Acetabular Cup Placement in THA: A Matched-pair Controlled Study [J].
Domb, Benjamin G. ;
El Bitar, Youssef F. ;
Sadik, Adam Y. ;
Stake, Christine E. ;
Botser, Itamar B. .