An assessment of the inter-rater and intra-rater reliability of the modified Gordon pin infection classification system

被引:0
作者
Bafor, Anirejuoritse [1 ]
Skals, Regitze Gyldenholm [2 ]
Shen, Ming [3 ]
Iobst, Christopher A. [1 ]
Rahbek, Ole [4 ]
Kold, Soren [4 ]
Fridberg, Marie [4 ]
机构
[1] Nationwide Childrens Hosp, Ctr Limb Lengthening & Reconstruct, Dept Orthopaed, Columbus, OH 43205 USA
[2] Aalborg Univ Hosp Res Data & Biostat, Aalborg, Denmark
[3] Aalborg Univ, Dept Elect Syst, Aalborg, Denmark
[4] Aalborg Univ Hosp, Dept Orthopaed, Interdisciplinary Orthopaed, Aalborg, Denmark
来源
DIGITAL HEALTH | 2024年 / 10卷
关键词
Modified Gordon score; inter-rater reliability; pin-site infection; pin-site labeling; EXTERNAL FIXATION; GRADING SYSTEM; SITE INFECTION; COMPLICATIONS;
D O I
10.1177/20552076241277672
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Objectives A grading system deployed for continuous at-home monitoring of pin sites would potentially increase the chances of early detection of pin-site infections and the commencement of early treatment. The first five grades of the Modified Gordon Pin Site Classification Scheme (MGS) meet the criteria for a visual-only, digital assessment-based grading system. The aim of this study was to assess the inter- and intra-rater reliability of the first five grades of the MGS from digital images.Methods We graded 1082 pin sites from 572 digital photographs of patients who underwent external fixator treatment for various conditions using the first five grades of the MGS classification scheme. Percent agreement and kappa values were calculated to determine the inter- and intra-rater agreement. Results were also grouped into two categories: "good" consisting of MGS grades 0-2 and "bad" made up of grades 3 and 4 for sensitivity analysis. We also analyzed reliability based on color only using MGS grades 0 and 2.Results A total of 843 of the 1082 pin sites were scored by all raters. There was moderate reliability between raters with a Fleiss kappa value of 0.48 [CI 0.45, 0.51]. The reliability remained moderate based on grouping into "good' versus "bad" and based on color with Fleiss kappa values of 0.48 [CI 0.45, 0.52] and 0.45 [CI 0.42, 0.49], respectively. Intra-rater reliability demonstrated substantial agreement with kappa values of 0.63.Conclusion Scoring pin sites from digital images with the MGS demonstrated only moderate inter-rater reliability. Modifying the use of digital photos is needed for at-home monitoring of pin sites.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] The inter-rater reliability of the Wheelchair Interface Questionnaire
    Davis, Abigail Bridey
    Sheafer, Vicki
    Rispin, Karen
    Layton, Natasha
    DISABILITY AND REHABILITATION-ASSISTIVE TECHNOLOGY, 2021, 16 (02) : 166 - 171
  • [32] Inter-rater reliability of the Subjective Global Assessment: A systematic literature review
    Steenson, Jessica
    Vivanti, Angela
    Isenring, Elizabeth
    NUTRITION, 2013, 29 (01) : 350 - 352
  • [33] Comparison of Inter-Rater Reliability Techniques in Performance-Based Assessment
    Mancar, Sinem Arslan
    Gulleroglu, H. Deniz
    INTERNATIONAL JOURNAL OF ASSESSMENT TOOLS IN EDUCATION, 2022, 9 (02): : 515 - 533
  • [34] Intra-rater reliability of the Modified Modified Ashworth Scale (MMAS) in the assessment of upper-limb muscle spasticity
    Ansari, Noureddin Nakhostin
    Naghdi, Soofia
    Mashayekhi, Masoud
    Hasson, Scott
    Fakhari, Zahra
    Jalaie, Shohreh
    NEUROREHABILITATION, 2012, 31 (02) : 215 - 222
  • [35] Degenerative findings on MRI of the cervical spine: an inter- and intra-rater reliability study
    Moll, Line Thorndal
    Kindt, Morten Wasmod
    Stapelfeldt, Christina Malmose
    Jensen, Tue Secher
    CHIROPRACTIC & MANUAL THERAPIES, 2018, 26
  • [36] Inter-rater reliability of the assessment of adverse drug reactions in the hospitalised elderly
    B. Tangiisuran
    V. Auyeung
    L. Cheek
    C. Rajkumar
    J. Graham Davies
    The journal of nutrition, health & aging, 2013, 17 : 700 - 705
  • [37] Inter-rater reliability of the assessment of adverse drug reactions in the hospitalised elderly
    Tangiisuran, B.
    Auyeung, V.
    Cheek, L.
    Rajkumar, C.
    Davies, G.
    JOURNAL OF NUTRITION HEALTH & AGING, 2013, 17 (08) : 700 - 705
  • [38] The inter-rater reliability of the Pulmonary Embolism Severity Index
    Fraga, Montserrat
    Taffe, Patrick
    Mean, Marie
    Hugli, Olivier
    Witzig, Stephanie
    Waeber, Gerard
    Aujesky, Drahomir
    THROMBOSIS AND HAEMOSTASIS, 2010, 104 (06) : 1258 - 1262
  • [39] Inter-rater reliability study of the modified Oxford Grading Scale and the Peritron manometer
    Jorge Ferreira, Cristine Homsi
    Barbosa, Patricia Brentegani
    Souza, Flaviane de Oliveira
    Antonio, Flavia Ignacio
    Franco, Maira Menezes
    Bo, Kari
    PHYSIOTHERAPY, 2011, 97 (02) : 132 - 138
  • [40] Testing inter-rater reliability of the Urostomy Education Scale
    Kristensen, Susanne A.
    Jensen, Bente Thoft
    EUROPEAN JOURNAL OF ONCOLOGY NURSING, 2016, 20 : 17 - 23