Asymptomatic iatrogenic bilateral occlusion of vertebral artery after atlantoaxial fusion: a case report

被引:0
作者
Jung, Jong-Hoon [1 ]
Lee, Jung-Kil [1 ]
Moon, Bong Ju [2 ]
Hong, Jong-Hwan [3 ]
机构
[1] Chonnam Natl Univ Hosp & Med Sch, Dept Neurosurg, Gwangju, South Korea
[2] Yonsei Univ, Coll Med, Gangnam Severance Hosp, Dept Neurosurg,Spine & Spinal Cord Inst, Seoul, South Korea
[3] Chonnam Natl Univ Hosp, Dept Neurosurg, Gwangju, South Korea
关键词
Atlanto-axial fusion; collateral circulation; iatrogenic; os odontoideum; vertebral artery; C1 LATERAL MASS; POLYAXIAL SCREW; CERVICAL-SPINE; FIXATION; INJURY; SURGERY;
D O I
10.5152/j.aott.2024.23206
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Vertebral arterial injury (VAI) remains a fatal complication of C1-C2 posterior screw fixation. Herein, we report asymptomatic bilateral VAI that was caused by screws following C1-C2 posterior fixation. A 34-year-old woman with cerebral palsy experienced quadriple-gia after a fall. Cervical computed tomography (CT) showed increased ADI, with os odontoideum, for which C1 pedicle screw and C2 pedicle-lamina screw fixation were performed. Cervical magnetic resonance imaging (MRI) conducted for postoperative weakness in shoulder elevation demonstrated a well-decompressed spinal cord. However, neck CT angiography revealed bilateral vertebral artery (VA) violations by the C1 pedicle screw that induced occlusion of the V2 and V3 segments of both VA, with intact V4 segments. Diffusion-weighted imaging showed no evidence of infarction. Cerebral angiography showed reconstitution of posterior circulation via the left fetal posterior communicating artery. Steroid treatment-induced improvement in shoulder elevation to the preoperative level, and no neurolog-ical deterioration has been detected for 3 years postoperatively. Prevention of VAI is one of the most important objectives when perform-ing posterior cervical screw fixation. The screw should be inserted considering the rotation of C1 and C2. Notably, variations in cerebral circulation, which enable collateral blood flow to the posterior circulation, can lead to different sequelae in patients with iatrogenic VAI
引用
收藏
页码:308 / 311
页数:69
相关论文
共 12 条
  • [1] A Fetal-type Variant Posterior Communicating Artery and its Clinical Significance
    Capone, Stephen
    Shah, Nagma
    George-St Bernard, Rachael R.
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (07)
  • [2] O-arm navigation versus C-arm guidance for pedicle screw placement in spine surgery: a systematic review and meta-analysis
    Feng, Weili
    Wang, Weihao
    Chen, Shubiao
    Wu, Kezhou
    Wang, Hu
    [J]. INTERNATIONAL ORTHOPAEDICS, 2020, 44 (05) : 919 - 926
  • [3] Cervical collaterals may protect against stroke after blunt vertebral artery injury
    Fink K.R.
    Fink J.R.
    Cohen W.A.
    [J]. Emergency Radiology, 2011, 18 (6) : 545 - 549
  • [4] Posterior C1-C2 fusion with polyaxial screw and rod fixation
    Harms, J
    Melcher, RP
    [J]. SPINE, 2001, 26 (22) : 2467 - 2471
  • [5] Comparative Analysis of Surgical Outcomes of C1-2 Fusion Spine Surgery between Intraoperative Computed Tomography Image Based Navigation-Guided Operation and Fluoroscopy-Guided Operation
    Lee, Jun Seok
    Son, Dong Wuk
    Lee, Su Hun
    Ki, Sung Soon
    Lee, Sang Weon
    Song, Geun Sung
    [J]. JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2020, 63 (02) : 237 - 247
  • [6] Vertebral artery injury in cervical spine surgery: anatomical considerations, management, and preventive measures
    Peng, Chan W.
    Chou, Benedict T.
    Bendo, John A.
    Spivak, Jeffrey M.
    [J]. SPINE JOURNAL, 2009, 9 (01) : 70 - 76
  • [7] Shen Francis H, 2004, Spine J, V4, P689, DOI 10.1016/j.spinee.2004.05.001
  • [8] Atlantoaxial fixation using the polyaxial screw-rod system
    Stulik, Jan
    Vyskocil, Tomas
    Sebesta, Petr
    Kryl, Jan
    [J]. EUROPEAN SPINE JOURNAL, 2007, 16 (04) : 479 - 484
  • [9] C1 lateral mass screws for posterior segmental stabilization of the upper cervical spine and a new method of three-point rigid fixation of the C1-C2 complex
    Vilela, Marcelo D.
    Jermani, Charles
    Braga, Bruno P.
    [J]. ARQUIVOS DE NEURO-PSIQUIATRIA, 2006, 64 (3B) : 762 - 767
  • [10] Vertebral artery injury in C1-2 transarticular screw fixation: Results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves
    Wright, NM
    Lauryssen, C
    [J]. JOURNAL OF NEUROSURGERY, 1998, 88 (04) : 634 - 640