Cataract Surgery in the Small Adult Eye: A Review

被引:0
作者
Moore, Jonathan E. [1 ,2 ,3 ,4 ]
Mcneely, Richard N. [1 ]
Moutari, Salissou [4 ]
机构
[1] Cathedral Eye Clin, Belfast, North Ireland
[2] Tianjin Med Univ, Tianjin, Peoples R China
[3] Aston Univ, Coll Hlth & Life Sci, Birmingham, England
[4] Queens Univ Belfast, Sch Math & Phys, Belfast, Antrim, North Ireland
关键词
biometry; cataract surgery; complications; Nanophthalmos; small eye; INTRAOCULAR-LENS IMPLANTATION; POWER CALCULATION FORMULAS; AXIAL LENGTH; VISUAL OUTCOMES; POSTERIOR MICROPHTHALMOS; ARTIFICIAL-INTELLIGENCE; REFRACTIVE OUTCOMES; HIGH-HYPEROPIA; NANOPHTHALMOS; ACCURACY;
D O I
10.1111/ceo.14510
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Modern cataract surgery continues to advance, yet intraocular lens (IOL) based surgery in the small adult eye remains challenging. Thorough preoperative assessment and surgical preparation optimise postoperative outcomes in these cases. Advances in IOL power calculation, including artificial intelligence-driven formulas, improve accuracy; however, careful consideration of biometry and IOL power selection is still necessary because inaccuracies can produce significant errors. Limited availability of high-powered IOLs to fully correct high refractive errors may necessitate further intervention. Surgical techniques have evolved to address the unique anatomical challenges of small eyes, improving safety and outcomes. Knowledge of the potential risks inherent in these cases can assist the surgeon in modifying the operative technique accordingly. This review discusses essential preoperative assessments, IOL power selection, surgical techniques, and potential complications, offering guidance for surgeons performing cataract surgery on small adult eyes.
引用
收藏
页数:12
相关论文
共 106 条
  • [21] Accuracy and feasibility of axial length measurements by a new optical low-coherence reflectometry-based device in eyes with posterior subcapsular cataract[J]. Einan-Lifshitz, Adi;Rozenberg, Assaf;Wang, Li;Koch, Douglas D.;Shoshany, Nadav;Zadok, David;Avni, Isaac;Abulafia, Adi. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017(07)
  • [22] Cataract surgery in adult eyes with short axial length[J]. Elhusseiny, Abdelrahman M. M.;Sallam, Ahmed B. B. CURRENT OPINION IN OPHTHALMOLOGY, 2023(01)
  • [23] Visual and Refractive Outcomes in Hyperopic Pseudophakic Patients Implanted with the Acri.LISA 366D Multifocal Intraocular Lens[J]. Fernandez-Vega, Luis;Alfonso, Jose F.;Baamonde, Begona;Madrid-Costa, David;Montes-Mico, Robert;Lozano, Javier. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009(02)
  • [24] Comparison of refractive and visual outcomes of 3 presbyopia-correcting intraocular lenses[J]. Ferreira, Tiago B.;Ribeiro, Filomena J.;Silva, Diana;Matos, Ana Claudia;Gaspar, Sylvia;Almeida, Soraia. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022(03)
  • [25] Contrast sensitivity after refractive lens exchange with diffractive multifocal intraocular lens implantation in hyperopic eyes[J]. Ferrer-Blasco, Teresa;Montes-Mico, Robert;Cervino, Alejandro;Alfonso, Jose F.;Fernandez-Vega, Luis. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008(12)
  • [26] Intraocular lens calculation formula selection for short eyes: based on axial length and anterior chamber depth[J]. Gao, Ruoxi;Zhang, Jiaqing;Han, Xiaotong;Huang, Yiguo;Huang, Ruoxuan;Ye, Jinfeng;Wen, Ling;Qiu, Xiaozhang;Chen, Xiaoyun;Tan, Xuhua;Luo, Lixia. BMC OPHTHALMOLOGY, 2025(01)
  • [27] Intraocular lens power calculations in short eyes using 7 formulas[J]. Gokce, Sabite E.;Zeiter, John H.;Weikert, Mitchell P.;Koch, Douglas D.;Hill, Warren;Wang, Li. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017(07)
  • [28] Anterior Segment Features in Nanophthalmos With Secondary Chronic Angle Closure Glaucoma: An Ultrasound Biomicroscopy Study[J]. Guo, Congcong;Zhao, Zhenni;Zhang, Dandan;Liu, Jiafan;Li, Jianlong;Zhang, Jiamin;Sun, Nannan;Chen, Denghui;Zhang, Miao;Fan, Zhigang. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019(06)
  • [29] Challenges and approaches in modern biometry and IOL calculation[J]. Haigis, Wolfgang. SAUDI JOURNAL OF OPHTHALMOLOGY, 2012(01)
  • [30] Testing the dioptric power accuracy of exact-power-labeled intraocular lenses[J]. Hoffer, Kenneth J.;Calogero, Don;Faaland, Robert W.;Ilev, Ilko K. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009(11)