Intratracheal instillation for the testing of pulmonary toxicity in mice-Effects of instillation devices and feed type on inflammation

被引:1
|
作者
Hadrup, Niels [1 ,2 ]
Guldbrandsen, Michael [1 ]
Terrida, Eva [1 ]
Bendtsen, Katja M. S. [1 ]
Hougaard, Karin S. [1 ,3 ]
Jacobsen, Nicklas R. [1 ]
Vogel, Ulla [1 ,4 ]
机构
[1] Natl Res Ctr Working Environm, Lerso Parkalle 105, DK-2100 Copenhagen O, Denmark
[2] Tech Univ Denmark, Natl Food Inst, Res Grp Risk Benefit, Copenhagen, Denmark
[3] Univ Copenhagen, Dept Publ Hlth, Copenhagen, Denmark
[4] Tech Univ Denmark, Natl Food Inst, Copenhagen, Denmark
关键词
inhalation; mouse; pulmonary; toxicity; CARBON NANOTUBES; TIO2; NANOPARTICLES; LUNG INFLAMMATION; IN-VIVO; EXPOSURE; RESPONSES; BLACK; INHALATION; PAINTS; RATS;
D O I
10.1002/ame2.12503
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
BackgroundInhalation exposure is the gold standard when assessing pulmonary toxicity. However, it typically requires substantial amounts of test material. Intratracheal instillation is an alternative administration technique, where the test substance is suspended in a liquid vehicle and deposited into the lung via the trachea. Instillation requires minimal test material, delivers an exact dose deep into the lung, and is less labor-intensive than inhalation exposures. However, one shortcoming is that the procedure may induce short-term inflammation. To minimize this, we tested different modifications of the technique to identify the potential for refinement.MethodsFirst, we tested whether previous findings of increased inflammation could be confirmed. Next, we tested whether instillation with a disposable 1 mL syringe with ball-tipped steel-needle (Disposable-syringe/steel-needle) induced less inflammation than the use of our standard set-up, a 250 mu L reusable glass syringe with a disposable plastic catheter (Glass-syringe/plastic-catheter). Finally, we tested if access to pelleted and liquid feed prior to instillation affected inflammation. We evaluated inflammation by neutrophil numbers in bronchoalveolar fluid 24 h post-exposure.ResultsVehicle-instilled mice showed a small increase in neutrophil numbers compared to untreated mice. Neutrophil numbers were slightly elevated in the groups instilled with Disposable-syringe/steel-needle; an interaction with feed type indicated that the increase in neutrophils was more pronounced in combination with feed pellets compared to liquid feed. We found no difference between the feed types when using the Glass-syringe/plastic-catheter combination.ConclusionThe Glass-syringe/plastic-catheter combination induced the least exposure-related inflammation, confirming this as a preferred instillation procedure.
引用
收藏
页码:378 / 386
页数:9
相关论文
共 46 条
  • [1] Usefulness of Intratracheal Instillation Studies for Estimating Nanoparticle-Induced Pulmonary Toxicity
    Morimoto, Yasuo
    Izumi, Hiroto
    Yoshiura, Yukiko
    Fujishima, Kei
    Yatera, Kazuhiro
    Yamamoto, Kazuhiro
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2016, 17 (02)
  • [2] Pulmonary Toxicity of Ceria Nanoparticles in Mice After Intratracheal Instillation
    Xue, Lingxi
    He, Xiao
    Li, Yuanyuan
    Qu, Meihua
    Zhang, Zhiyong
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2013, 13 (10) : 6575 - 6580
  • [3] Repeated intratracheal instillation effects of commonly used vehicles in toxicity studies with mice
    Kim, In-Hyeon
    Kim, Je-Hein
    Park, Se-Woong
    Lim, Su-Jin
    Kim, Jeong Hwan
    Park, Cheoljin
    Lee, Jinsoo
    Kim, Sung-Hwan
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [4] Pulmonary toxicity of printer toner following inhalation and intratracheal instillation
    Morimoto, Yasuo
    Oyabu, Takako
    Horie, Masanori
    Kambara, Tatsunori
    Izumi, Hiroto
    Kuroda, Etsushi
    Creutzenberg, Otto
    Bellmann, Bernd
    Pohlmann, Gerhard
    Schuchardt, Sven
    Hansen, Tanja
    Ernst, Heinrich
    INHALATION TOXICOLOGY, 2013, 25 (12) : 679 - 690
  • [5] Pulmonary toxicity assessment of multiwalled carbon nanotubes in rats following intratracheal instillation
    Reddy, A. Rama Narsimha
    Reddy, Y. Narsimha
    Krishna, Devarakonda R.
    Himabindu, V.
    ENVIRONMENTAL TOXICOLOGY, 2012, 27 (04) : 211 - 219
  • [6] The acute pulmonary and thrombotic effects of cerium oxide nanoparticles after intratracheal instillation in mice
    Nemmar, Abderrahim
    Al-Salam, Suhail
    Beegam, Sumaya
    Yuvaraju, Priya
    Ali, Badreldin H.
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2017, 12 : 2913 - 2922
  • [7] Effect of Intratracheal Instillation of ZnO Nanoparticles on Acute Lung Inflammation Induced by Lipopolysaccharides in Mice
    Wang, Ping
    Zhang, Lin
    Liao, Yanxia
    Du, Juan
    Xu, Mengying
    Zhao, Wen
    Yin, Shuxian
    Chen, Guilan
    Deng, Yu
    Li, Yiran
    Xue, Xue
    Yang, Yiming
    Hu, Guodong
    Chen, Yinghua
    TOXICOLOGICAL SCIENCES, 2020, 173 (02) : 373 - 386
  • [8] Validation of intratracheal instillation as an alternative for aerosol inhalation toxicity testing
    Sabaitis, CP
    Leong, BKJ
    Rop, DA
    Aaron, CS
    JOURNAL OF APPLIED TOXICOLOGY, 1999, 19 (02) : 133 - 140
  • [9] Biodistribution and toxicity of nanodiamonds in mice after intratracheal instillation
    Zhang, Xiaoyong
    Yin, Jilei
    Kang, Cheng
    Li, Jing
    Zhu, Ying
    Li, Wenxin
    Huang, Qing
    Zhu, Zhiyong
    TOXICOLOGY LETTERS, 2010, 198 (02) : 237 - 243
  • [10] Induction of chronic inflammation in mice treated with titanium dioxide nanoparticles by intratracheal instillation
    Park, Eun-Jung
    Yoon, Junheon
    Choi, Kyunghee
    Yi, Jongheop
    Park, Kwangsik
    TOXICOLOGY, 2009, 260 (1-3) : 37 - 46