Mechanical effect of taper position in abutment hole and screw taper angles on implant system and peri-implant tissue: a finite element analysis

被引:0
作者
Hou, Hu [1 ]
Zhang, Jianguo [1 ]
Huang, Song [1 ]
Hu, Fengling [2 ,3 ]
Yu, Youcheng [3 ]
Song, Liang [4 ]
机构
[1] Shanghai Inst Technol, Sch Mech Engn, Shanghai, Peoples R China
[2] Shanghai Geriatr Med Ctr, Dept Stomatol, Shanghai, Peoples R China
[3] Fudan Univ, Zhongshan Hosp, Dept Stomatol, Shanghai, Peoples R China
[4] Fudan Univ, Shanghai Peoples Hosp 5, Dept Stomatol, Shanghai, Peoples R China
关键词
Dental implants; abutment hole; screw taper angles; finite element analysis; DENTAL IMPLANT; STRESS-DISTRIBUTION; CONNECTIONS; PROSTHESES; RETRIEVAL;
D O I
10.1080/10255842.2024.2423253
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
PurposeThe study aimed to investigate the mechanical effects of the taper position in the abutment hole and the screw taper angles on the implant system and peri-implant tissue using finite element analysis.MethodsFour taper positions (L1, L2, L3, L4) in the abutment hole were established using 3D software and five screw taper angles (30 degrees, 60 degrees, 90 degrees, 120 degrees, 180 degrees) were set.ResultTaper position significantly affects the stresses in the implant system. The 30 degrees and 180 degrees angles (L4 position) showed less stress than other angles.ConclusionElevated taper position and reasonable taper angle are beneficial in reducing the stress in the implant system.
引用
收藏
页数:9
相关论文
共 50 条
[21]   A SENSITIVITY STUDY BY FINITE ELEMENT ANALYSIS FOR THE ABUTMENT-IMPLANT-BONE SYSTEM [J].
Muraev, A. A. ;
Tatoyan, A. D. ;
Dolgalev, A. A. ;
Vershinin, A. V. ;
Yakovlev, M. Ya. ;
Ivanov, S. Yu ;
Konovalov, D. A. ;
Petrovsky, K. A. ;
Levin, V. A. .
MATHEMATICS AND MECHANICS OF COMPLEX SYSTEMS, 2022, 10 (01) :1-20
[22]   Peri-implant bone tissue strains in cases of dehiscence: a finite element study [J].
Van Oosterwyck, H ;
Duyck, J ;
Vander Sloten, J ;
Van der Perre, G ;
Naert, I .
CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (03) :327-333
[23]   Finite Element Analysis (FEA) for Influence of Variation in Dental Implant Dimensions (Length and Diameter) on Peri-implant Bone Stress/Strain Distribution: A Systematic Review [J].
Sayed, Arshad Jamal ;
Mohsin, Syed Fareed ;
Garg, Kamlesh Kumar ;
Agwan, Muhammad Atif Saleem ;
Tareen, Sabahat Ullah Khan ;
Alruthea, Mohammed Sulaiman ;
Mohan, Sasankoti .
PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2025, 41 (01) :318-330
[24]   The effect of direct and indirect force transmission on peri-implant bone stress - a contact finite element analysis [J].
Rand, Annike ;
Stiesch, Meike ;
Eisenburger, Michael ;
Greuling, Andreas .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 (10) :1132-1139
[25]   Mechanical Influence of Edentulous Mandible Morphology on Peri-implant Bone in Implant Prosthetics: 3D Finite Element Analysis [J].
Hamada, Takumi ;
Gonda, Tomoya ;
Murase, Kohei ;
Maeda, Yoshinobu ;
Ikebe, Kazunori .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (06) :931-937
[26]   Effects of the Implant Design on Peri-Implant Bone Stress and Abutment Micromovement: Three-Dimensional Finite Element Analysis of Original Computer-Aided Design Models [J].
Yamanishi, Yasufumi ;
Yamaguchi, Satoshi ;
Imazato, Satoshi ;
Nakano, Tamaki ;
Yatani, Hirofumi .
JOURNAL OF PERIODONTOLOGY, 2014, 85 (09) :E333-E338
[27]   Finite element analysis of the biomechanical effects of PEEK dental implants on the peri-implant bone [J].
Schwitalla, A. D. ;
Abou-Emara, M. ;
Spintig, T. ;
Lackmann, J. ;
Mueller, W. D. .
JOURNAL OF BIOMECHANICS, 2015, 48 (01) :1-7
[28]   Influence of Platform and Abutment Angulation on Peri-Implant Bone. A Three-Dimensional Finite Element Stress Analysis [J].
Martini, Ana Paula ;
Barros, Rosalia Moreira ;
Freitas Junior, Amilcar Chagas ;
Rocha, Eduardo Passos ;
de Almeida, Erika Oliveira ;
Ferraz, Cacilda Cunha ;
Jimenez Pellegrin, Maria Cristina ;
Anchieta, Rodolfo Bruniera .
JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (06) :663-670
[29]   Preventing stress singularities in peri-implant bone - a finite element analysis using a graded bone model [J].
Roffmann, Oliver ;
Stiesch, Meike ;
Greuling, Andreas .
COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024, 27 (05) :547-557
[30]   The effect of different occlusal contact situations on peri-implant bone stress - A contact finite element analysis of indirect axial loading [J].
Brune, Annike ;
Stiesch, Meike ;
Eisenburger, Michael ;
Greuling, Andreas .
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 99 :367-373