Thermodynamic analysis and performance optimization on an ultra-low-temperature cascade refrigeration system using refrigerants R290 and R170

被引:2
作者
Ji, Shenrui [1 ]
Liu, Zhan [1 ]
Li, Jiafeng [2 ]
Wang, Tao [3 ]
机构
[1] China Univ Min & Technol, Sch Mech & Civil Engn, State Key Lab Geomech & Deep Underground Engn, Xuzhou, Peoples R China
[2] Anhui Shen Ran Nat Gas Co Ltd, Anhui, Peoples R China
[3] Zhengzhou Univ Light Ind, Sch Energy & Power Engn, Zhengzhou, Peoples R China
基金
中国博士后科学基金;
关键词
cascade refrigeration system; performance optimization; refrigerant pair R290-R170; thermodynamic analysis; ultra-low temperature; CYCLE;
D O I
10.1002/apj.3179
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
To meet the strict requirement on whole chain of vaccine production, storage, transportation, and distribution, most researches have been done on cascade refrigeration systems to achieve high operation performance, while a research gap on the performance exploration of eco-friendly refrigeration systems still exists. In this paper, a comprehensive thermodynamic model was established to analyze the operation performance of a pre-cooled cascade refrigeration system with eco-friendly refrigerants propane (R290) and ethane (R170). Based on the present thermodynamic model, the performance optimization on the R290-R170 cascade refrigerator was made with considerations of degree of subcooling, degree of superheat, evaporation temperature, condensation temperature, cascade condensation temperature, and cascade temperature difference. Variations of the coefficient of performance, exergy destruction, and total exergy efficiency of the refrigeration cycle were analyzed. Two mathematical correlations yielding the optimal cascade condensation temperature and maximized coefficient of performance were developed by multilinear regression analysis. When the evaporation temperature is - 60 degrees C, the maximized coefficient of performance and total exergy efficiency are 1.276 and 49.51%. This paper demonstrates the potential for improving the R290-R170 cascade refrigeration system and furnishes the basis for further exploration on ultra-low-temperature refrigerators.
引用
收藏
页数:17
相关论文
共 50 条
[1]   Natural and synthetic refrigerants, global warming: A review [J].
Abas, Naeem ;
Kalair, Ali Raza ;
Khan, Nasrullah ;
Haider, Aun ;
Saleem, Zahid ;
Saleem, Muhammad Shoaib .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 90 :557-569
[2]   Comparative energy and exergy analysis of a subcritical cascade refrigeration system using low global warming potential refrigerants [J].
Aktemur, Cenker ;
Ozturk, Ilhan Tekin ;
Cimsit, Canan .
APPLIED THERMAL ENGINEERING, 2021, 184
[3]   Thermodynamic Assessment of Using Water as a Refrigerant in Cascade Refrigeration Systems With Other Environmentally Friendly Refrigerants [J].
Alkhulaifi, Yousif M. ;
Mokheimer, Esmail M. A. .
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2022, 144 (02)
[4]   Optimizing cascade refrigeration systems with low GWP refrigerants for Low-Temperature Applications: A thermodynamic analysis [J].
Arefin, Md. Miraj ;
Mondal, Dipayan ;
Islam, Md. Ashraful .
ENERGY CONVERSION AND MANAGEMENT-X, 2024, 24
[5]   Experimental research on a Joule-Thomson refrigeration cycle with mixture R170/R290 for 60 °C low-temperature freezer [J].
Bai, Tao ;
Li, Dawei ;
Xie, Hongxu ;
Yan, Gang ;
Yu, Jianlin .
APPLIED THERMAL ENGINEERING, 2021, 186
[6]   Enhancing thermodynamic performance with an advanced combined power and refrigeration cycle with dual LNG cold energy utilization [J].
Baigh, Tajwar A. ;
Saif, Mostofa J. ;
Mustakim, Ashraf ;
Nanzeeba, Fairooz ;
Khan, Yasin ;
Ehsan, M. Monjurul .
HELIYON, 2024, 10 (15)
[7]  
Bani Issa AAM., 2022, MODELING ULTRALOW TE
[8]  
Berchowitz D., 1991, 18 INT C REFR MONTR, V8, P848, DOI 10.1299/kikaib.75.7582089
[9]   A comparative study on exergetic, exergoeconomic and exergoenvironmental assessments of two internal auto-cascade refrigeration cycles [J].
Boyaghchi, Fateme Ahmadi ;
Asgari, Sahar .
APPLIED THERMAL ENGINEERING, 2017, 122 :723-737
[10]   Energy comparison based on experimental results of a cascade refrigeration system pairing R744 with R134a, R1234ze(E) and the natural refrigerants R290, R1270, R600a [J].
Cabello, R. ;
Andreu-Nacher, A. ;
Sandhez, D. ;
Llopis, R. ;
Vidan-Falomir, F. .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 148 :131-142