Bone Densitometric Analysis using Cone Beam Computed Tomography (Cone Beam CT) and Computed Tomography (CT): Establishing the Correlation between Predicted and Actual Values

被引:0
作者
Kumar, Rashmit [1 ]
Punnoose, Kurian [2 ]
Chikkanna, Meenakumari [3 ]
Gunturu, Srikanth [4 ]
Alrifai, Mosa Mohammad [5 ]
Al Zahrani, Abdulghani Saeed [6 ]
Babu, J. Suresh [7 ]
Swarnalatha, C. [7 ]
Nayyar, Abhishek Singh [8 ,9 ]
机构
[1] Vananchal Dent Coll & Hosp, Dept Oral Med & Radiol, Garhwa, Jharkhand, India
[2] Univ Hail, Coll Dent, Dept Oral & Maxillofacial Surg, Hail, Saudi Arabia
[3] Majmaah Univ, Coll Dent, Dept Dent Restorat & Prosthodont, Al Majmaah, Saudi Arabia
[4] Drs Sudha & Nageswara Rao Siddhartha Inst Dent Sci, Dept Oral & Maxillofacial Surg, Gannavaram, Andhra Pradesh, India
[5] King Fahad Hosp, Dent Ctr, Sultanah, Al Madinah Al Munawarah, Madinah, Saudi Arabia
[6] Al Nuayriyah Gen Hosp, Dept Restorat Dent Sci, Nuayriyah, Dammam, Eastern Provinc, Saudi Arabia
[7] Univ Hail, Coll Dent, Dept Prevent Dent Sci, Div Periodontol, Hail, Saudi Arabia
[8] Saraswati Dhanwantari Dent Coll & Hosp, Dept Oral Med & Radiol, Parbhani, Maharashtra, India
[9] Post Grad Res Inst, Parbhani, Maharashtra, India
来源
ADVANCED BIOMEDICAL RESEARCH | 2025年 / 14卷 / 01期
关键词
Bone density; computed tomography (CT); cone beam computed tomography (cone beam CT); in-vitro study; MINERAL DENSITY; VOXEL VALUES; MULTISLICE; ACCURACY; CBCT;
D O I
10.4103/abr.abr_313_24
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background:One of the major drawbacks of cone beam computed tomography (cone beam CT) is that unlike CT, the gray density values obtained from cone beam CT are relative, and not absolute as obtained in the case of CT. The present study was conducted with the intent to perform a comparative bone densitometric analysis using cone beam CT and CT and to determine if there was a mathematical correlation between the two. Materials and Methods:The present in-vitro study included CT and cone beam CT scans of 30 dry mandibles wherein the gray density values from well-demarcated, precise anatomical areas were obtained, analyzed, and compared. Also, the dependent t-test and Pearson's correlation coefficient test were used for statistical analysis, while probability values (P values) < 0.05 were contemplated as being statistically significant. Results:Pearson's correlation between the gray density values for different combinations of point(s)/group(s) as derived on CT and cone beam CT images revealed the results to be statistically significant for each of the imaging methods used, individually and when compared in between the two methods, in all the cases (P < 0.001) when analyzed at 5% level of significance. Conclusions:The mean gray density values obtained with cone beam CT were found to be significantly higher than the ones derived from CT in the present study, though, a linear correlation was observed between the values obtained from cone beam CT and CT, which can be used to convert the relative values obtained with cone beam CT into absolute values derived with CT.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Correlations between fabric tensors computed on cone beam and micro computed tomography images
    Moreno, Rodrigo
    Borga, Magnus
    Klintstrom, Eva
    Brismar, Torkel
    Smedby, Orjan
    COMPUTATIONAL VISION AND MEDICAL IMAGE PROCESSING IV, 2014, : 393 - 398
  • [32] Clinical guidelines for dental cone-beam computed tomography
    Hayashi, Takafumi
    Arai, Yoshinori
    Chikui, Toru
    Hayashi-Sakai, Sachiko
    Honda, Kazuya
    Indo, Hiroko
    Kawai, Taisuke
    Kobayashi, Kaoru
    Murakami, Shumei
    Nagasawa, Masako
    Naitoh, Munetaka
    Nakayama, Eiji
    Nikkuni, Yutaka
    Nishiyama, Hideyoshi
    Shoji, Noriaki
    Suenaga, Shigeaki
    Tanaka, Ray
    ORAL RADIOLOGY, 2018, 34 (02) : 89 - 104
  • [33] Cone Beam Computed Tomography for Adaptive Radiotherapy Treatment Planning
    Srinivasan, Kavitha
    Mohammadi, Mohammad
    Shepherd, Justin
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2014, 34 (04) : 377 - 385
  • [34] PCXMC cone beam computed tomography dosimetry investigations
    Fetin, Aaron
    Cartwright, Lucy
    Sykes, Jonathan
    Wach, Alicja
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2022, 45 (01) : 205 - 218
  • [35] Applications of Cone Beam Computed Tomography in Orthodontics: A Review
    Tadinada, Aditya
    Marczak, Alana
    Yadav, Sumit
    Mukherjee, Padma M.
    TURKISH JOURNAL OF ORTHODONTICS, 2016, 29 (03) : 73 - 79
  • [36] PCXMC cone beam computed tomography dosimetry investigations
    Aaron Fetin
    Lucy Cartwright
    Jonathan Sykes
    Alicja Wach
    Physical and Engineering Sciences in Medicine, 2022, 45 : 205 - 218
  • [37] Applications of Cone Beam Computed Tomography in Orthodontics: An Overview
    Bora, Prateeksha
    Agrawal, Poonam
    Bagga, Dinesh Kumar
    Tiwari, Sakshi
    Singh, Aartika
    BIOSCIENCE BIOTECHNOLOGY RESEARCH COMMUNICATIONS, 2020, 13 (15): : 168 - 172
  • [38] Role of cone beam computed tomography in contemporary orthodontics
    Tadinada, Aditya
    Schneider, Sydney
    Yadav, Sumit
    SEMINARS IN ORTHODONTICS, 2018, 24 (04) : 407 - 415
  • [39] Cone Beam Computed Tomography (CBCT): Orthodontic Aspects
    Pazera, P.
    Bornstein, M. M.
    Jordi, P.
    Katsaros, C.
    INFORMATIONEN AUS ORTHODONTIE UND KIEFERORTHOPAEDIE, 2010, 42 (04): : 251 - 260
  • [40] Use of cone beam computed tomography in otolaryngologic treatments
    Cakli, Hamdi
    Cingi, Cemal
    Ay, Yazgi
    Oghan, Fatih
    Ozer, Torun
    Kaya, Ercan
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2012, 269 (03) : 711 - 720