Performance evaluation of ultrasonic-assisted dynamic ice melting in ice storage systems: An experimental study

被引:0
作者
Yan, Wei-Mon [1 ,2 ]
Yeh, Ri-Sheng [1 ,2 ]
Sajjad, Uzair [1 ,2 ]
Chien, Liang-Han [1 ,2 ]
Amani, Mohammad [3 ]
机构
[1] Natl Taipei Univ Technol, Dept Energy & Refrigerating Air Conditioning Engn, Taipei 10608, Taiwan
[2] Natl Taipei Univ Technol, Res Ctr Energy Conservat New Generat Residential C, Taipei 10608, Taiwan
[3] Arak Univ Technol, Dept Mech Engn, Arak, Iran
关键词
Ice storage system; Ultrasonic assisted ice melting; Dynamic ice melting; Cooling performance; Internal ice melting; Energy Efficiency;
D O I
10.1016/j.est.2024.114045
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study presents the construction of an ice storage tank equipped with an internal ice-on-coil system. The cooling performance of the ice storage system is enhanced by utilizing the cavitation phenomenon induced by ultrasonic vibration in water. Active water circulation and spraying within the tank enhance cooling efficiency by promoting uniform temperature distribution. An analysis is conducted on the impact of various operating parameters, such as output powers of 200 W, 400 W, and 584 W, frequencies of 40 kHz, 80 kHz, and 120 kHz, and three different placements of the oscillator, on the cooling performance of ultrasonic-assisted static ice melting, dynamic ice melting, and ultrasonic-assisted dynamic ice melting systems. Ultrasonic-assisted static ice melting refers to ice melting with stationary water, while ultrasonic-assisted dynamic ice melting involves water circulation, enhancing heat transfer. The study examines performance indicators like instantaneous cooling rate, cumulative cooling capacity, average cooling rate, melting time, and heat gain by the system. The findings indicate that higher ultrasonic power levels enhance the average cooling rate and reduce the melting time by approximately 50 % and 32.2 %, respectively. However, the frequency does not have a significant effect on the cooling performance. In addition, the ice storage system had a significant increase in cooling rate of 294.87 % when utilizing the ultrasonic-assisted dynamic ice melting system. Furthermore, the melting time was lowered by 71 % in comparison to the static ice melting method. Of all the parameters, the power parameter has the greatest impact. The impact of the ultrasonic oscillator placement parameter is secondary, while the influence of the frequency parameter on the cooling performance is not significant.
引用
收藏
页数:19
相关论文
共 26 条
  • [1] Experimental study of the effects of ultrasound on the heat transfer enhancement in a 3D-printed minichannel heat sink
    Alenezi, Abdulmajeed
    Chandrasekaran, Gokul
    Noe, Cameron
    Phelan, Patrick
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 209
  • [2] Maximisation of heat transfer in a coil in tank PCM cold storage system
    Castell, A.
    Belusko, M.
    Bruno, F.
    Cabeza, L. F.
    [J]. APPLIED ENERGY, 2011, 88 (11) : 4120 - 4127
  • [3] Heat and mass transfer of evaporative cooler with elliptic tube heat exchangers- an experimental study
    Chien, Liang-Han
    Chen, De-Cian
    Liu, Yu-Jie
    Yan, Wei-Mon
    Ghalambaz, Mohammad
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2021, 127
  • [4] A review on convective heat transfer enhancement using ultrasound
    Dehbani, Maryam
    Rahimi, Masoud
    Rahimi, Zohreh
    [J]. APPLIED THERMAL ENGINEERING, 2022, 208
  • [5] Experimental assessment of a solar water tank integrated with nano-enhanced PCM and a stirrer
    Dhaou, Mohamed Houcine
    Mellouli, Sofiene
    Alresheedi, Faisal
    El-Ghoul, Yassine
    [J]. ALEXANDRIA ENGINEERING JOURNAL, 2022, 61 (10) : 8113 - 8122
  • [6] The impingement of liquid boiling droplet onto a molten phase change material as a direct-contact solidification method
    Faghiri, Shahin
    Mohammadi, Omid
    Hosseininaveh, Hossein
    Shafii, Mohammad Behshad
    [J]. THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 23
  • [7] Investigation and optimization of solidification performance of a triplex-tube latent heat thermal energy storage system by rotational mechanism
    Huang, Xinyu
    Li, Fangfei
    Xiao, Tian
    Guo, Junfei
    Wang, Fan
    Gao, Xinyu
    Yang, Xiaohu
    He, Ya-Ling
    [J]. APPLIED ENERGY, 2023, 331
  • [8] Analysis of applying fin for charging process of phase change material inside H-shaped thermal storage
    Izadi, Mohsen
    Hajjar, Ahmad
    Alshehri, Hashim M.
    Saleem, Arslan
    Galal, Ahmed M.
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2022, 139
  • [9] Experimental investigation of the effect of vibration on phase change material (PCM) based battery thermal management system
    Joshy, Naveen
    Hajiyan, Mohammadhossein
    Siddique, Abu Raihan Mohammad
    Tasnim, Syeda
    Simha, Hari
    Mahmud, Shohel
    [J]. JOURNAL OF POWER SOURCES, 2020, 450
  • [10] Experimental and theoretical investigations of solidification and melting of ice for the design and operation of an ice store
    Koller, Torsten
    Spindler, Klaus
    Mueller-Steinhagen, Hans
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (05): : 1253 - 1265