Determination of Pu isotopes in urine samples by a pseudo-isotope dilution method using non-isotopic tracer 237Np

被引:0
作者
Qin, Ning [1 ,2 ]
Zheng, Jian [1 ]
Yang, Guosheng [1 ]
Kim, Eunjoo [1 ]
Kurihara, Osamu [1 ]
机构
[1] Natl Inst Quantum Sci & Technol, Inst Radiol Sci, 4-9-1 Anagawa,Inage Ku, Chiba 2638555, Japan
[2] Univ Sci & Technol Beijing, Beijing 100083, Peoples R China
关键词
Pseudo-isotope dilution; Urine; Pu isotopes; Uncertainty; Parameter sensitivity; ICP-MS; MASS-SPECTROMETRY; SEDIMENT SAMPLES; NP-237; PLUTONIUM; INJECTION; TUMORS; SOIL;
D O I
10.1016/j.talanta.2025.127768
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Plutonium (Pu) isotopes are extremely hazardous radioactive materials. Rapid analysis of Pu in urine from contaminated persons is important for radiobiological verification and exposure dose assessment. Since Pu is classified as a nuclear fuel nuclide, the use of 242Pu tracer for isotope dilution (ID) quantification is commonly controlled and regulated, which can affect timely exposure dose assessment. In this study, a pseudo-isotope dilution (PID) method using a non-isotopic tracer (NIT) 237Np was developed. The method accuracy was validated using both spiked samples and urine standard reference materials. Uncertainties throughout the experiment, instrument analysis, and activity calculation were characterized by Monte Carlo simulation (MCS). The results showed that the activity concentrations of 239Pu, 240Pu, and 237Np quantified by PID were consistent with those measured by the ID method. For spiked samples with theoretical 239Pu concentrations of 0.028 pg/mL and 0.014 pg/mL, the coefficients of variation (CVs) derived by the PID method were 0.043 and 0.074, respectively, which were comparable to those quantified by the ID method with CVs of 0.042 and 0.045. From the parameter sensitivity analysis, the ICP-MS signal intensities of 237Np and 240Pu isotopes after standard addition and the 237Np signal intensity before the standard addition were identified as the key factors affecting the quantification of 239Pu, 240Pu and 237Np, respectively. Due to its considerable accuracy, precision and extensive application conditions, the PID method is judged to be a promising tool for radiological assessment of contaminated persons in an internal exposure situation and for providing decision-making information in emergency medical treatments.
引用
收藏
页数:11
相关论文
共 47 条
  • [11] Ellison SLR., 2012, Quantifying uncertainty in analytical measurement
  • [12] Simultaneous determination of ultra-trace level 237Np and Pu isotopes in soil and sediment samples by SF-ICP-MS with a single column chromatographic separation
    Huang, Zhaoya
    Ni, Youyi
    Wang, Hai
    Zheng, Jian
    Yamazaki, Shinnosuke
    Sakaguchi, Aya
    Long, Xinggui
    Uchida, Shigeo
    [J]. MICROCHEMICAL JOURNAL, 2019, 148 : 597 - 604
  • [13] Iwai S, 2019, J RADIOL PROT, V39, P1092, DOI 10.1088/1361-6498/ab26e1
  • [14] Simultaneous analysis of 237Np and Pu isotopes in environmental samples by ICP-SF-MS coupled with automated sequential injection system
    Kim, CS
    Kim, CK
    Lee, KJ
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (06) : 743 - 750
  • [15] Kim E., 12 INT C HLTH EFF IN, P2019
  • [16] Uncertainty evaluation in reference material characterization by double isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS)
    Lee, Jong Wha
    [J]. METROLOGIA, 2022, 59 (06)
  • [17] BIOLOGICAL EFFECTIVENESS OF NP-237
    LEVDIK, TI
    LYUBCHAN.ER
    LEMBERG, VK
    BULDAKOV, LA
    PESTERNI.VM
    [J]. HEALTH PHYSICS, 1972, 22 (06): : 643 - +
  • [18] Double Spike-Standard Addition Technique and Its Application in Measuring Isotopes
    Lu, Zhuo
    Zhu, Jian-Ming
    Tan, Decan
    Johnson, Thomas M.
    Wang, Xiangli
    [J]. ANALYTICAL CHEMISTRY, 2023, 95 (04) : 2253 - 2259
  • [19] Concurrent determination of 237Np and Pu isotopes using ICP-MS: analysis of NIST environmental matrix standard reference materials 4357, 1646a, and 2702
    Matteson, Brent S.
    Hanson, Susan K.
    Miller, Jeffrey L.
    Oldham, Warren J., Jr.
    [J]. JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2015, 142 : 62 - 67
  • [20] Rapid radiochemical analysis of uranium and plutonium in emergency urine samples
    Mei, Lingzi
    Shao, Hui
    Cui, Lingzhi
    Yang, Jinmin
    Zhang, Lei
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024, 333 (03) : 1357 - 1365