An Investigation Into the Impact of Impedance Measurement Parameters on the Limit of Detection of QCM-D Using Machine Learning Model Chaining

被引:0
作者
Kirimli, Ceyhun E. [1 ]
Elgun, Elcim [2 ]
Yuksel, Mehmet Mert [1 ]
Tugtag, Selin Yagmur [1 ]
机构
[1] Acibadem Univ, Dept Biomed Engn, ?, TR-34752 Istanbul, Turkiye
[2] Acibadem Univ, Dept Basic Sci, TR-34752 Istanbul, Turkiye
关键词
Impedance measurement; Resonant frequency; Impedance; Resonance; Frequency measurement; Sensors; Optimization; Machine learning; Harmonic analysis; Biosensors; Experimental design; impedance spectroscopy; machine learning (ML); quartz crystal microbalance with energy dissipation (QCM-D); QUARTZ-CRYSTAL MICROBALANCE; BOVINE SERUM-ALBUMIN; FREQUENCY;
D O I
10.1109/JSEN.2024.3511274
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Impedance spectroscopy is an appropriate measurement method for quartz crystal microbalance with energy dissipation (QCM-D) monitoring, especially for machine learning (ML) applications, given the vast amount of information it can provide. When quartz crystal microbalance (QCM) is used in a liquid medium for biosensing, it responds to mass change, and the viscoelastic properties of both the medium and the film are deposited on the electrode surface. It has been previously observed that the limit of detection (LOD) experiments employing QCM may be increased by at least 12-fold, by an application of ML-assisted optimization of impedance measurement parameters while enabling a reduction of the number of experiments by tenfold. In this study, ML methodologies are employed to quantify how a selection of such measurement parameters is possible and affects the calculated viscoelastic parameters of the bulk fluid and thickness along with the viscosity of bovine serum albumin (BSA) thin films adsorbed on gold electrodes. Results indicate that the LOD for bulk fluid viscosity and thickness of BSA thin films can vary up to sixfold and threefold, respectively, depending on the chosen measurement parameters. By implementing this ML framework, viscoelastic modeling accuracy in complex media and thin-film applications can be significantly improved through impedance spectroscopy, thus resulting in an increased overall sensitivity in QCM biosensing.
引用
收藏
页码:5688 / 5696
页数:9
相关论文
共 35 条
  • [21] Convergence properties of the Nelder-Mead simplex method in low dimensions
    Lagarias, JC
    Reeds, JA
    Wright, MH
    Wright, PE
    [J]. SIAM JOURNAL ON OPTIMIZATION, 1998, 9 (01) : 112 - 147
  • [22] Protein reactions with surface-bound molecular targets detected by oblique-incidence reflectivity difference microscopes
    Landry, J. P. m
    Sun, Y. S.
    Guo, X. W.
    Zhu, X. D.
    [J]. APPLIED OPTICS, 2008, 47 (18) : 3275 - 3288
  • [23] Virtual Sensor Array Based on Butterworth-Van Dyke Equivalent Model of QCM for Selective Detection of Volatile Organic Compounds
    Li, Dongsheng
    Xie, Zihao
    Qu, Mengjiao
    Zhang, Qian
    Fu, Yongqing
    Xie, Jin
    [J]. ACS APPLIED MATERIALS & INTERFACES, 2021, 13 (39) : 47043 - 47051
  • [24] Montgomery D., 2011, Engineering Statistics
  • [25] Review-Electronic Circuit Systems for Piezoelectric Resonance Sensors
    Park, Jong-Yoon
    Choi, Jin-Woo
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (03)
  • [26] On the measurement of thin liquid overlayers with the quartz-crystal microbalance
    Rodahl, M
    Kasemo, B
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1996, 54 (1-3) : 448 - 456
  • [27] VERWENDUNG VON SCHWINGQUARZEN ZUR WAGUNG DUNNER SCHICHTEN UND ZUR MIKROWAGUNG
    SAUERBREY, G
    [J]. ZEITSCHRIFT FUR PHYSIK, 1959, 155 (02): : 206 - 222
  • [28] A QCM immunosensor for Salmonella detection with simultaneous measurements of resonant frequency and motional resistance
    Su, XL
    Li, YB
    [J]. BIOSENSORS & BIOELECTRONICS, 2005, 21 (06) : 840 - 848
  • [29] Elastic and viscous bond components in the adhesion of colloidal particles and fibrillated streptococci to QCM-D crystal surfaces with different hydrophobicities using Kelvin-Voigt and Maxwell models
    van der Westen, Rebecca
    Sharma, Prashant K.
    De Raedt, Hans
    Vermue, Ijsbrand
    van der Mei, Henny C.
    Busscher, Henk J.
    [J]. PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2017, 19 (37) : 25391 - 25400
  • [30] 'Missing mass' effect in biosensor's QCM applications
    Voinova, MV
    Jonson, M
    Kasemo, B
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (10) : 835 - 841