6/0 PROLENE DOUBLE-FLANGED INTRAOCULAR LENS SUTURELESS SCLERAL FIXATION WITH A 27-GAUGE NEEDLE FOR INTRAOCULAR LENS SURGERY

被引:0
作者
Pao, Shu-I. [1 ,2 ]
Chang, Yun-Hsiang [1 ]
Chen, Jiann-Torng [1 ,2 ]
机构
[1] Triserv Gen Hosp, Natl Def Med Ctr, Dept Ophthalmol, 161,Sec 6,Minquan E Rd, Taipei 11490, Taiwan
[2] Natl Def Med Ctr, Grad Inst Med Sci, Taipei, Taiwan
来源
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES | 2025年 / 45卷 / 02期
关键词
astigmatism axial degree; IOL; IOP; logMAR; SE; sutureless scleral fixation; IMPLANTATION; VITRECTOMY;
D O I
10.1097/IAE.0000000000004289
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To report the initial experience of a modified intraocular lens (IOL) scleral fixation technique using 6/0 prolene in a double-flanged sutureless technique with a 27-gauge needle. Methods: Twenty-nine consecutive patients with IOL surgery were retrospectively reviewed between December 2021 and October 2023. Early Treatment Diabetic Retinopathy Study letters, spherical equivalent (SE), astigmatism axial degree, and intraocular pressure were evaluated at baseline and 1, 2, 3, and 6 months postoperatively. Surgery-related complications were evaluated during follow-up. Results: Early Treatment Diabetic Retinopathy Study letters or SE at 1, 2, 3, and 6 months postoperation was significantly improved compared with baseline levels. Patients with younger (estimate [SE] = 8.011 [2.485], P = 0.006), preoperative lens drop (estimate [SE] = 8.621 [2.906], P = 0.009), idiopathic cataract (estimate [SE] = 6.021 [2.099], P = 0.048), high baseline Early Treatment Diabetic Retinopathy Study letters (estimate [SE] = 15.449 [2.352], P < 0.001), or low baseline SE (estimate [SE] = 6.357 [2.406], P = 0.018) had the greatest improvement in Early Treatment Diabetic Retinopathy Study letters during follow-up. Patients with preoperative lens or IOL dislocation had a greater postoperative SE improvement than those with preoperative lens or IOL subluxation (dislocation vs. subluxation: estimate [SE] = -189.235 [70.692], P = 0.016). There were no cases of vitreous hemorrhage, cystoid macular edema, endophthalmitis, subluxation, or dislocation were observed during the 6-month follow-up. Conclusion: This modified IOL scleral fixation technique is a simple, safe, and efficient method that avoids haptic manipulation and slippage, reduces postoperative complications, achieves completely sutureless surgery, and results in an achievement of surgical refractive goals.
引用
收藏
页码:278 / 285
页数:8
相关论文
共 30 条
  • [1] Outcomes of intraocular lens scleral fixation with the friction knot technique
    Aaltonen, Petri
    Oskala, Pertti
    Immonen, Ilkka
    [J]. ACTA OPHTHALMOLOGICA, 2019, 97 (04) : E506 - E513
  • [2] Fibrin glue-assisted sutureless posterior chamber intraocular lens implantation in eyes with deficient posterior capsules
    Agarwal, Amar
    Kumar, Dhivya Ashok
    Jacob, Soosan
    Baid, Chandresh
    Agarwal, Athiya
    Srinivasan, Sridhar
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09) : 1433 - 1438
  • [3] Four-point scleral fixation of posterior chamber intraocular lenses without scleral flaps
    Almashad, Gamal Youssef
    Abdelrahman, Ayman Mohamed
    Khattab, Hatem Amin
    Samir, Ahmed
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (06) : 693 - 695
  • [4] Modern Cataract Surgery: Unfinished Business and Unanswered Questions
    Apple, David J.
    Escobar-Gomez, Marcela
    Zaugg, Brian
    Kleinmann, Guy
    Borkenstein, Andreas E.
    [J]. SURVEY OF OPHTHALMOLOGY, 2011, 56 : S3 - S53
  • [5] Astbury Nick, 2016, Community Eye Health, V29, P27
  • [6] A computerized method of visual acuity testing: Adaptation of the early treatment of diabetic retinopathy study testing protocol
    Beck, RW
    Moke, PS
    Turpin, AH
    Ferris, FL
    Sangiovanni, JP
    Johnson, CA
    Birch, EE
    Chandler, DL
    Cox, TA
    Blair, RC
    Kraker, RT
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (02) : 194 - 205
  • [7] A 1-Year Prospective Comparative Study of Sutureless Flanged Intraocular Lens Fixation and Conventional Sutured Scleral Fixation in Intraocular Lens Dislocation
    Do, Jae Rock
    Park, Su Jin
    Mukai, Ryo
    Kim, Hong Kyun
    Shin, Jae Pil
    Park, Dong Ho
    [J]. OPHTHALMOLOGICA, 2021, 244 (01) : 68 - 75
  • [8] Enaholo ES., 2024, SPHERICAL EQUIVALENT
  • [9] Comparative Evaluation of Suture-assisted and Fibrin Glue-assisted Scleral Fixated Intraocular Lens Implantation
    Ganekal, Sunil
    Venkataratnam, Sathyamurthy
    Dorairaj, Syril
    Jhanji, Vishal
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (04) : 249 - 252
  • [10] Minimally Invasive Ab Interno Four-Point Scleral Fixation of Intraocular Lens
    Hadayer, Amir
    Puri, Sidharth
    Adeniran, Janelle Fassbender
    Wang, Wei
    Kaplan, Henry J.
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 : 21 - 23