Behaviour of stainless steel reinforced concrete beams in fire

被引:0
作者
Mehwish, Javaria [1 ]
Shamass, Rabee [1 ]
Cashell, Katherine A. [2 ]
机构
[1] Brunel Univ, Dept Civil & Environm Engn, London, England
[2] UCL, Dept Civil Environm & Geomat Engn, London, England
基金
英国工程与自然科学研究理事会;
关键词
Finite element modelling; Fire resistance; Parametric study; FLEXURAL BEHAVIOR;
D O I
10.1016/j.conbuildmat.2025.140230
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Stainless steel possesses excellent mechanical and physical properties, has outstanding corrosion resistance, and is extremely ductile. It finds extensive use in the construction industry and has increasingly been employed in reinforced concrete structures in recent years as there is greater focus on longevity and life cycle costing. However, there has been limited to no research on the fire resistance of stainless steel reinforced concrete structures. In this study, a finite element model of a stainless steel reinforced concrete (SSRC) beam is developed and verified to simulate the fire resistance of the SSRC beams. The model is validated through comparison with available test data before it is employed to undertake a comparative study to evaluate the fire performance of carbon-reinforced and stainless steel-reinforced concrete beams. Various factors, such as load ratio, reinforcement ratio, and concrete strength, are analysed for their impact on the fire resistance of these beams. The ductile failure observed in stainless steel-reinforced concrete (SSRC) beams during fire incidents suggests their potential as replacements for carbon steel-reinforced concrete (CSRC) beams, particularly in fire-prone areas where structural integrity is paramount. SSRC beams can achieve comparable fire resistance to CSRC beams with lower reinforcement ratios, thereby reducing reinforcement requirements potentially. It is shown that stainless steel reinforced concrete beams deform more under flexure than equivalent carbon steel beams largely owing to their greater survival time and resistance to greater temperatures, significantly affecting the fire resistance. A proposed critical temperature limit of 765 degrees C for SS reinforcing rebar under fire exposure is recommended as a design guideline.
引用
收藏
页数:16
相关论文
共 38 条
[1]   Effect of basalt fibers on the flexural behavior of concrete beams reinforced with BFRP bars [J].
Abed, Farid ;
Alhafiz, Abdul Rahman .
COMPOSITE STRUCTURES, 2019, 215 :23-34
[2]  
Ahmad Z, 2006, PRINCIPLES OF CORROSION ENGINEERING AND CORROSION CONTROL, P120, DOI 10.1016/B978-075065924-6/50005-2
[3]  
[Anonymous], 1999, 13407 ISO, P1
[4]  
[Anonymous], 2008, ASTM E119
[5]  
[Anonymous], 2020, Abaqus User Manual
[6]  
[Anonymous], 2013, fib Model Code for Concrete Structures 2010
[7]  
[Anonymous], 1987, BS 476-3
[8]  
Clarks A., 1978, Technical Report No 42
[9]   Evaluation of fracture energy, toughness, brittleness, and fracture process zone properties for lightweight concrete exposed to high temperatures [J].
Dabbaghi, Farshad ;
Fallahnejad, Hossein ;
Nasrollahpour, Sepideh ;
Dehestani, Mehdi ;
Yousefpour, Hossein .
THEORETICAL AND APPLIED FRACTURE MECHANICS, 2021, 116
[10]   Response of Restrained Concrete Beams under Design Fire Exposure [J].
Dwaikat, M. B. ;
Kodur, V. K. R. .
JOURNAL OF STRUCTURAL ENGINEERING, 2009, 135 (11) :1408-1417