Trueness of Customized Abutment Data Superimposition on Incompletely Scanned Impression: An In Vitro Study

被引:0
|
作者
Baek, Yeon-Wha [1 ]
Kim, Bongju [2 ]
Kim, Myung-Joo [3 ,4 ]
Kwon, Ho-Beom [3 ,4 ]
Lim, Young-Jun [3 ,4 ]
机构
[1] Seoul Natl Univ Dent Hosp, Dept Prosthodont, Gwanak Br, Seoul, South Korea
[2] Seoul Natl Univ, Dent Hosp, Dent Life Sci Res Inst, Innovat Res & Support Ctr Dent Sci, Seoul, South Korea
[3] Seoul Natl Univ, Dent Hosp, Sch Dent, Dept Prosthodont, Seoul, South Korea
[4] Seoul Natl Univ, Dent Hosp, Dent Res Inst, Sch Dent, Seoul, South Korea
关键词
customized abutment; digital impression; digital superimposition; implant abutment impression; intraoral scanner; RETRACTION TECHNIQUES; ACCURACY; GINGIVAL;
D O I
10.1111/clr.14401
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study evaluated the feasibility and trueness of superimposing titanium customized abutment library data onto scans of abutments with incomplete areas along margins or proximal surfaces, comparing this approach to the CAD program's hole-filling function. Material and Methods: A dental model with one implant was used. A titanium customized abutment was scanned to create abutment library data. Reference data were generated using a laboratory scanner (Medit T500) and the abutment and neighboring teeth were scanned 10 times with Medit I500, an intraoral scanner (IOS group). Superimposition with abutment library data was performed for fully scanned (F), margin-deleted (M1 and M2), and proximal-deleted scans (P). The "Close holes" function of exocad DentalCAD was applied to create the PF group. Trueness was assessed by comparing root mean square (RMS) and point-based deviations against reference data using Geomagic control X. Statistical analysis was conducted using one-way ANOVA and Tukey HSD tests. Results: Superimposition improved trueness compared to the IOS group, reducing RMS from 42.11 +/- 1.11 to 36.37-36.61 mu m in the F, M1, M2, and P groups (p < 0.001). No significant differences were observed among superimposition groups. The PF group exhibited greater deviations than all superimposition groups (p < 0.001). Point-based analysis showed significant improvement in superimposed groups (p < 0.05), except at marginal ridges (p > 0.05). The hole-filling function did not enhance trueness (p > 0.05). Conclusions: Superimposing abutment library data improve the trueness of intraoral scans, even when areas along margins and proximal surfaces are incomplete.
引用
收藏
页数:11
相关论文
共 15 条
  • [1] Evaluation of the Clinical Accuracy of Implant Abutment-Level Impression Technique Using Digital Superimposition of Customized Abutment
    Kim, Jin-Wan
    Cho, Won-Tak
    Bae, Eun-Bin
    Huh, Jung-Bo
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2021, 34 (06) : 752 - 755
  • [2] Accuracy of Customized Abutment Data Superimposition According to the Extent of the Scanning Area
    Park, Tae-Min
    Jung, Chang-Mo
    Yun, Mi-Jung
    Huh, Jung-Bo
    Lee, So-Hyoun
    Sailer, Irena
    Lee, Hyeonjong
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2021, 34 (03) : 390 - 394
  • [3] Effect of custom abutment data superimposition on the accuracy of implant abutment level scanning: An in vitro study
    Baek, Yeon-Wha
    Lim, Young-Jun
    Kim, Myung-Joo
    Kwon, Ho-Beom
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06): : 1208 - 1217
  • [4] Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
    Francesco Guido Mangano
    Oleg Admakin
    Matteo Bonacina
    Henriette Lerner
    Vygandas Rutkunas
    Carlo Mangano
    BMC Oral Health, 20
  • [5] Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
    Mangano, Francesco Guido
    Admakin, Oleg
    Bonacina, Matteo
    Lerner, Henriette
    Rutkunas, Vygandas
    Mangano, Carlo
    BMC ORAL HEALTH, 2020, 20 (01)
  • [6] The influence of the superimposition procedure and type of intraoral impression on the superimposition accuracy of CBCT scans with dental impressions in implant planning: an in-vitro study
    Motel, Constantin
    Kirschner, Carolin
    Foertsch, Felix
    Buchbender, Mayte
    Wichmann, Manfred
    Matta, Ragai-Edward
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2025, 11 (01)
  • [7] Feasibility of Using a Prosthetic-Based Impression Template to Improve the Trueness and Precision of a Complete Arch Digital Impression on Four and Six Implants: An In Vitro Study
    Tallarico, Marco
    Lumbau, Aurea Immacolata
    Scrascia, Roberto
    Demelas, Gianluca
    Sanseverino, Franco
    Amarena, Rocco
    Meloni, Silvio Mario
    MATERIALS, 2020, 13 (16)
  • [8] Implant-abutment screw removal torque values between customized titanium abutment, straight titanium abutment, and hybrid zirconia abutment after a million cyclic loading: an in vitro comparative study
    Disayut Klongbunjit
    Weerapan Aunmeungtong
    Pathawee Khongkhunthian
    International Journal of Implant Dentistry, 7
  • [9] Implant-abutment screw removal torque values between customized titanium abutment, straight titanium abutment, and hybrid zirconia abutment after a million cyclic loading: an in vitro comparative study
    Klongbunjit, Disayut
    Aunmeungtong, Weerapan
    Khongkhunthian, Pathawee
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2021, 7 (01)
  • [10] EFFECT OF LAB PROCEDURES AND ULTRASONIC-BATH CLEANING ON CUSTOMIZED IMPLANT ABUTMENT POLLUTION: AN IN VITRO STUDY
    Roth, Deborah
    Compere, Philippe
    Van Hede, Dorien
    Lamy, Marc
    Lambert, France
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2024, 37 (03) : e136 - e148