Short-term changes in the trabecular iris angle and anterior chamber during wear of scleral lenses with different diameters

被引:0
作者
Queiruga-Pineiro, Juan [1 ]
Lozano-Sanroma, Javier [1 ]
Barros, Alberto [1 ]
Rodriguez-Una, Ignacio [1 ]
Fernandez-Vega Cueto-Felgueroso, Luis [1 ]
Merayo-Lloves, Jesus [1 ]
机构
[1] Univ Oviedo, Fernandez Vega Univ Inst, Ophthalmol Res Fdn, Oviedo, Spain
关键词
Anterior chamber; optical coherence tomography; scleral lenses; trabecular iris angle; CLEARANCE; THICKNESS; MINI;
D O I
10.1080/08164622.2024.2418822
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Clinical relevanceScleral lens (SL) compression on the conjunctiva/episclera during wear may alter adjacent structures related to aqueous humour drainage.BackgroundThe aim of this work was to assess short-term changes in the four quadrants of trabecular iris angle (TIA) and anterior chamber parameters during SL wear, using anterior segment optical coherence tomography (AS-OCT).MethodsProspective study was conducted involving 16 healthy subjects with a mean age of 28 +/- 5 years. Two SL of diameter 15.80 mm (L1) and 16.80 mm (L2) with the same parameters were used for 2 hours in different days. The central fluid reservoir (FR), the TIA in superior, inferior, nasal, temporal quadrants, and anterior chamber parameters; anterior chamber depth (ACD), anterior chamber width (ACW), anterior chamber area (ACAr) and anterior chamber volume (ACV) were measured with AS-OCT. These measurements were performed immediately after SL application (0 h), one hour (1 h) and two hours (2 h) of SL wear.ResultsTIA decreases significantly in the superior quadrant at 2 hours of L2 wear (-5.19 +/- 7.79 degrees) (p = 0.04). In this sector, differences were also observed between the changes induced by both lenses during the 2 hours of wear (p = 0.04) and between first and second hours of wear (p = 0.04). ACD was significantly lower with L1 (-0.09 +/- 0.14 mm) relative to L2 (0.00 +/- 0.06 mm) between immediately after the application and 2 hours of wear (p = 0.02). A significant reduction in ACAr at 1 hour (-0.65 +/- 0.75 mm2) (p = 0.01) and 2 hours of wear (-0.81 +/- 1.15 mm2) (p = 0.04), as well as in ACW at 2 hours (-0.11 +/- 0.14 mm) (p = 0.02) compared to immediately after application of L1 was found.ConclusionSmall changes in TIA and anterior chamber occur during two hours of SL wear, but these changes are of limited clinical relevance in healthy subjects.
引用
收藏
页数:7
相关论文
共 35 条
  • [31] Miniscleral lens wear influences corneal curvature and optics
    Vincent, Stephen J.
    Alonso-Caneiro, David
    Collins, Michael J.
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2016, 36 (02) : 100 - 111
  • [32] Corneal changes following short-term miniscleral contact lens wear
    Vincent, Stephen J.
    Alonso-Caneiro, David
    Collins, Michael J.
    [J]. CONTACT LENS & ANTERIOR EYE, 2014, 37 (06) : 461 - 468
  • [33] Anatomical and physiological considerations in scleral lens wear: Eyelids and tear film
    Walker, Maria K.
    Schornack, Muriel M.
    Vincent, Stephen J.
    [J]. CONTACT LENS & ANTERIOR EYE, 2021, 44 (05)
  • [34] Correlation between Intraocular Pressure and Angle Configuration Measured by OCT
    Xu, Benjamin Y.
    Burkemper, Bruce
    Lewinger, Juan Pablo
    Jiang, Xuejuan
    Pardeshi, Anmol A.
    Richter, Grace
    Torres, Mina
    McKean-Cowdin, Roberta
    Varma, Rohit
    [J]. OPHTHALMOLOGY GLAUCOMA, 2018, 1 (03): : 158 - 166
  • [35] Refractive Error and Anterior Chamber Depth as Risk Factors in Primary Angle Closure Disease: The Chinese American Eye Study
    Zhou, Sarah
    Pardeshi, Anmol A.
    Burkemper, Bruce
    Apolo, Galo
    Cho, Austin
    Jiang, Xuejuan
    Torres, Mina
    McKean-Cowdin, Roberta
    Varma, Rohit
    Xu, Benjamin Y.
    [J]. JOURNAL OF GLAUCOMA, 2023, 32 (04) : 257 - 264