Short-term changes in the trabecular iris angle and anterior chamber during wear of scleral lenses with different diameters

被引:0
作者
Queiruga-Pineiro, Juan [1 ]
Lozano-Sanroma, Javier [1 ]
Barros, Alberto [1 ]
Rodriguez-Una, Ignacio [1 ]
Fernandez-Vega Cueto-Felgueroso, Luis [1 ]
Merayo-Lloves, Jesus [1 ]
机构
[1] Univ Oviedo, Fernandez Vega Univ Inst, Ophthalmol Res Fdn, Oviedo, Spain
关键词
Anterior chamber; optical coherence tomography; scleral lenses; trabecular iris angle; CLEARANCE; THICKNESS; MINI;
D O I
10.1080/08164622.2024.2418822
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Clinical relevanceScleral lens (SL) compression on the conjunctiva/episclera during wear may alter adjacent structures related to aqueous humour drainage.BackgroundThe aim of this work was to assess short-term changes in the four quadrants of trabecular iris angle (TIA) and anterior chamber parameters during SL wear, using anterior segment optical coherence tomography (AS-OCT).MethodsProspective study was conducted involving 16 healthy subjects with a mean age of 28 +/- 5 years. Two SL of diameter 15.80 mm (L1) and 16.80 mm (L2) with the same parameters were used for 2 hours in different days. The central fluid reservoir (FR), the TIA in superior, inferior, nasal, temporal quadrants, and anterior chamber parameters; anterior chamber depth (ACD), anterior chamber width (ACW), anterior chamber area (ACAr) and anterior chamber volume (ACV) were measured with AS-OCT. These measurements were performed immediately after SL application (0 h), one hour (1 h) and two hours (2 h) of SL wear.ResultsTIA decreases significantly in the superior quadrant at 2 hours of L2 wear (-5.19 +/- 7.79 degrees) (p = 0.04). In this sector, differences were also observed between the changes induced by both lenses during the 2 hours of wear (p = 0.04) and between first and second hours of wear (p = 0.04). ACD was significantly lower with L1 (-0.09 +/- 0.14 mm) relative to L2 (0.00 +/- 0.06 mm) between immediately after the application and 2 hours of wear (p = 0.02). A significant reduction in ACAr at 1 hour (-0.65 +/- 0.75 mm2) (p = 0.01) and 2 hours of wear (-0.81 +/- 1.15 mm2) (p = 0.04), as well as in ACW at 2 hours (-0.11 +/- 0.14 mm) (p = 0.02) compared to immediately after application of L1 was found.ConclusionSmall changes in TIA and anterior chamber occur during two hours of SL wear, but these changes are of limited clinical relevance in healthy subjects.
引用
收藏
页数:7
相关论文
共 35 条
  • [1] Morphological changes in the conjunctiva, episclera and sclera following short-term miniscleral contact lens wear in rigid lens neophytes
    Alonso-Caneiro, David
    Vincent, Stephen J.
    Collins, Michael J.
    [J]. CONTACT LENS & ANTERIOR EYE, 2016, 39 (01) : 53 - 61
  • [2] Bergmanson JP., 2011, Clinical ocular anatomy and physiology, V17th ed.
  • [3] The impact of short-term fenestrated scleral lens wear on intraocular pressure
    Cheung, Samuel Y.
    Collins, Michael J.
    Vincent, Stephen J.
    [J]. CONTACT LENS & ANTERIOR EYE, 2020, 43 (06) : 585 - 588
  • [4] Scleral asymmetry as a potential predictor for scleral lens compression
    Consejo, Alejandra
    Behaegel, Josephine
    Van Hoey, Maarten
    Iskander, D. Robert
    Rozema, Jos J.
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2018, 38 (06) : 609 - 616
  • [5] Variation of clearance considering viscosity of the solution used in the reservoir and following scleral lens wear over time
    Courey, Claudine
    Michaud, Langis
    [J]. CONTACT LENS & ANTERIOR EYE, 2017, 40 (04) : 260 - 266
  • [6] de Leon JMS., 2013, Curr Ophthalmol Rep, V1, P80, DOI [10.1007/s40135-013-0013-5, DOI 10.1007/s40135-013-0013-5]
  • [7] Rethinking contact lens discomfort
    Efron, Nathan
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2018, 101 (01) : 1 - 3
  • [8] Influence of Apical Clearance on Mini-Scleral Lens Settling, Clinical Performance, and Corneal Thickness Changes
    Esen, Fehim
    Toker, Ebru
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2017, 43 (04): : 230 - 235
  • [9] Potential contraindications to scleral lens wear
    Fadel, Daddi
    Kramer, Elise
    [J]. CONTACT LENS & ANTERIOR EYE, 2019, 42 (01) : 92 - 103
  • [10] Modern scleral lenses: Mini versus large
    Fadel, Daddi
    [J]. CONTACT LENS & ANTERIOR EYE, 2017, 40 (04) : 200 - 207