Flexural performance of UHPC sandwich panels with UHPC-filled stainless steel pipe shear connectors

被引:3
作者
Ke, Lu [1 ,2 ]
Wu, Xiulong [1 ]
Yan, Banfu [1 ]
Li, Wei [3 ]
Li, Youlin [1 ]
机构
[1] Guangxi Univ, Sch Civil Engn & Architecture, State Key Lab Featured Met Mat & Life cycle Safety, Nanning 530004, Peoples R China
[2] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
[3] Hunan Univ, Coll Civil Engn, Changsha 410082, Peoples R China
基金
中国国家自然科学基金;
关键词
Flexural performance; Ultra-high performance concrete (UHPC); Sandwich panels; Finite element analysis; FINITE-ELEMENT-ANALYSIS; MECHANICAL PERFORMANCE; CONCRETE; BEHAVIOR; PRECAST; COMPOSITE; WALL; BEAMS;
D O I
10.1016/j.istruc.2024.107721
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A type of ultra-high performance concrete (UHPC) sandwich panel with UHPC-filled stainless steel pipe connectors (USPSPC) has been developed, demonstrating exceptional flexural capacity and thermal insulation performance. Four-point flexural tests were conducted on two UHPC sandwich panels to investigate their failure modes, load-deflection responses, and relative slips between the top and bottom slabs. Finite element analysis (FEA) was performed to examine the effects of panel height, top and bottom slab thickness, longitudinal reinforcement ratio of the bottom slab, and the diameter of the stainless steel pipes on the flexural performance. Additionally, the anti-slip stiffness and degree of composite action (DCA) of the sandwich panels were analyzed through numerical modeling. The results indicated that the flexural failure process can be divided into three stages: elastic, cracking, and yielding. The cracks of the sandwich panel with a higher DCA (specimen SP1) initiated in the pure bending section, and the failure mode was similar to that of solid concrete panels. In contrast, the sandwich panel with a lower DCA (specimen SP2) exhibited concentrated cracks in the shear-span section and failed due to excessive deflection. FEA results showed that both the panel height and the diameter of the steel pipe connectors significantly influenced the flexural performance. Increasing the panel height from 15 cm to 20 cm resulted in a 53.6 % and 39.6 % increase in cracking and ultimate loads, respectively. Increasing the diameter of the steel pipe connectors from 42 mm to 48 mm led to a 24.6 % and 21.3 % increase in cracking and ultimate loads, respectively. The stiffness of all sandwich panels met the deflection limit requirements under normal service load. Additionally, numerical analysis results indicated that reducing the height of the sandwich panel and increasing the diameter of the stainless steel pipes positively affected both DCA and anti-slip stiffness of the sandwich panels. The findings of this study provide valuable recommendations for the flexural design of these innovative sandwich panels.
引用
收藏
页数:21
相关论文
共 66 条
[1]   Increasing flexural performance of hybrid sandwich panels by using strain hardening cementitious base composite and glass fiber-reinforced polymer [J].
Abdolpour, Hassan ;
Garzon-Roca, Julio ;
Mameghani, Pouya H. M. H. .
JOURNAL OF COMPOSITE MATERIALS, 2019, 53 (01) :19-31
[2]  
Aguanno M., 2013, Fire resistance tests on cross-laminated timber floor panels: an experimental and numerical analysis, DOI [10.22215/etd/2013-07044, DOI 10.22215/ETD/2013-07044]
[3]  
[Anonymous], 2022, T/CECS 1216-2022
[4]  
[Anonymous], 2019, GB/T 50081-2019
[5]  
[Anonymous], 2009, Standard for test methods for fiber reinforced concrete
[6]  
[Anonymous], 2018, 33622018 JTG
[7]  
Basunbul I.A., 1991, Cement and Concrete Composites, V13, P21, DOI DOI 10.1016/0958-9465(91)90043-H
[8]   Out of plane performance of novel concrete sandwich panel using different geosynthetics [J].
Bishnoi, Upender ;
Roy, A. B. Danie ;
Kwatra, Naveen .
CONSTRUCTION AND BUILDING MATERIALS, 2021, 300
[9]   Flexural behaviour of light-weight sandwich panels composed by concrete and EPS [J].
Carbonari, G. ;
Cavalaro, S. H. P. ;
Cansario, M. M. ;
Aguado, A. .
CONSTRUCTION AND BUILDING MATERIALS, 2012, 35 :792-799
[10]   Experimental investigation and finite element analysis of flexural behavior of insulated concrete sandwich panels with FRP plate shear connectors [J].
Chen, An ;
Norris, Thomas G. ;
Hopkins, Paul M. ;
Yossef, Mostafa .
ENGINEERING STRUCTURES, 2015, 98 :95-108