Tensile behaviour of a novel grouted sleeve splice for high-strength rebars

被引:1
作者
Zhang, Xin [1 ]
Yu, Shenlu [1 ]
Feng, Shuaike [1 ]
Huang, Wei [2 ]
Li, Xiangyang [3 ]
机构
[1] Shandong Jianzhu Univ, Sch Civil Engn, Jinan 250101, Peoples R China
[2] Shandong High Speed Infrastruct Construct Co Ltd, Jinan 250061, Peoples R China
[3] Sungkyunkwan Univ, Dept Global Smart City, Suwon 16419, South Korea
关键词
Grouted sleeve splice; High-strength steel; Uniaxial tensile loading; Tensile strength; Embedded length; PIPE SPLICE; MECHANICAL-BEHAVIOR; PERFORMANCE;
D O I
10.1016/j.istruc.2024.107631
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study introduces a novel type of grouted sleeve fabricated from a standard low-alloy seamless steel pipe using cold-rolling techniques. The main goal is to achieve an effective connection between the high-strength steel (HSS) reinforcements in the joints of precast concrete structures. To investigate the structural performance of the developed splice under uniaxial tensile loading, 24 coupler specimens configured with 28 mm diameter HRB600 reinforcements were prepared. Two primary parameters, namely the embedded length of the spliced bar and number of inner concentric ribs rolled on the sleeve, were considered. By conducting direct pullout tests, the performance of the developed splices was thoroughly assessed based on the failure mode, bond stiffness, bond ductility, and strength. The test results demonstrated that increasing the bar embedded length and number of inner ribs enhances the initial bond stiffness and ductility of the splice. Increasing the quantity of inner ribs only in the inelastic region of the splice is effective for improving its tensile capacity. For grout splices with largediameter HSS bars, an embedded length of 8db is recommended to guarantee bar fracture failure and satisfy the specification requirements. This length exceeds that of splices with normal-strength reinforcements. Finally, a formula was proposed to estimate the inelastic region length and tensile strength of the proposed splice.
引用
收藏
页数:13
相关论文
共 45 条
[1]  
Ahmed AF, 2023, Mesop J Civ Eng, P1
[2]   Behavior of concrete columns reinforced with high-strength steel rebars under eccentric loading [J].
Alavi-Dehkordi, Sayedmahdi ;
Mostofinejad, Davood .
MATERIALS AND STRUCTURES, 2018, 51 (06)
[3]   Seismic Column-to-Footing Connections Using Grouted Splice Sleeves [J].
Ameli, M. J. ;
Brown, Dylan N. ;
Parks, Joel E. ;
Pantelides, Chris P. .
ACI STRUCTURAL JOURNAL, 2016, 113 (05) :1021-1030
[4]  
[Anonymous], 2015, JGJ355-2015
[5]  
[Anonymous], 1990, CEB-FIP Model Code 1990 Design Code
[6]  
[Anonymous], 2019, JG/T408-2019
[7]  
[Anonymous], 2019, A.C.I. Building Code Requirements for Structural Concrete (ACI 318-19) and Commentary (ACI 318R-19)
[8]  
[Anonymous], 2012, GB/T228.1-2010
[9]  
Baharuddin Abd Rahman Ahmad, 2015, Applied Mechanics and Materials, V789-790, P1176, DOI 10.4028/www.scientific.net/AMM.789-790.1176
[10]   Splice methods used for reinforcement steel bars: A state-of-the-art review [J].
Dabiri, Hamed ;
Kheyroddin, Ali ;
Dall'Asta, Andrea .
CONSTRUCTION AND BUILDING MATERIALS, 2022, 320