Comparison of Eye Axial Length Measurements Taken Using Partial Coherence Interferometry and OCT Biometry

被引:0
|
作者
Rizzieri, Nicola [1 ,2 ]
Facchin, Alessio [3 ,4 ]
机构
[1] Univ Latvia, Optometry & Vis Sci, LV-1586 Riga, Latvia
[2] Rizzieri Vis Ctr, I-46041 Asola, Italy
[3] Magna Graecia Univ Catanzaro, Neurosci Res Ctr, Dept Med & Surg Sci, I-88100 Catanzaro, Italy
[4] Inst Res & Studies Opt & Optometry, I-50059 Vinci, Italy
关键词
axial length; biometry; myopia; partial coherence interferometry; OCT; MYOPIA; IMI;
D O I
10.3390/vision8030046
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
This study evaluates the inter-device measurement properties of partial coherence interferometry (PCI) and spectral domain optical coherence tomography (SD-OCT) in measuring axial length, particularly for myopia management. We recruited 82 eyes from 41 adult participants with a mean age of 31.0 +/- 17.6 years and a mean spherical equivalent of -2.20 +/- 2.28 D. Axial length was measured using SD-OCT and PCI for both the right and left eyes. Agreement between the two measurements was assessed using Bland-Altman analysis, and graphs and values were compared with linear mixed models. The results show a near-to-zero and non-significant bias between measurements. The 95% limits of agreement showed a value of 0.06 mm. Both devices can accurately measure the axial length. OCT biometry performed with SD-OCT can be successfully interchanged with partial coherence interferometry, but they should be cautiously interchanged when performing longitudinal comparisons.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Comparison of Biometry Measurements Using Standard Partial Coherence Interferometry versus New Scheimpflug Tomography with Integrated Axial Length Capability
    Haddad, Jorge Selem
    Barnwell, Eliza
    Rocha, Karolinne Maia
    Ambrosio Jr, Renato
    Waring, George Oral
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 353 - 358
  • [2] Comment on: Comparison of axial length measurements insiliconeoil-filledeyesusing SS-OCT and partial coherence interferometry
    Gurnani, Bharat
    Kaur, Kirandeep
    Sharma, Trupti
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (06): : 654 - 654
  • [3] Comparison of axial length measurements in silicone oil-filled eyes using SS-OCT and partial coherence interferometry
    Zhang, Jiaqing
    Han, Xiaotong
    Zhang, Miao
    Liu, Zhenzhen
    Lin, Haowen
    Qiu, Xiaozhang
    Huang, Xinhua
    Li, Tao
    Lv, Lin
    Chen, Xiaoyun
    Jin, Guangming
    Tan, Xuhua
    Luo, Lixia
    Liu, Yizhi
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (12): : 1375 - 1380
  • [4] Measurement Reliability of Axial Length of the Human Eye by using Partial Coherence Interferometry
    Kim, Jae-Hyung
    Moon, Tae Hwan
    Chae, Ju Byung
    Hyung, Sungmin
    JOURNAL OF THE OPTICAL SOCIETY OF KOREA, 2014, 18 (05) : 546 - 550
  • [5] Axial length measurements in eyes with cataract and silicone oil tamponade: Partial coherence interferometry versus ultrasound biometry
    Lackerbauer, CA
    Mueller, AJ
    Ludwig, K
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S4 - S4
  • [6] Application of diffractive optics for axial eye length measurement using partial coherence interferometry
    Moller, B
    Rudolph, G
    Klopffleisch, A
    Donnerhacke, KH
    Dorsel, A
    LASERS IN OPHTHALMOLOGY IV, PROCEEDINGS OF, 1996, 2930 : 175 - 182
  • [7] Comparison of eye length measurement using partial coherence interferometry and clinical ultrasound
    Greenberg, KP
    Francis, EL
    Allam, A
    Desai, A
    Ying, GS
    Stone, RA
    Quinn, GE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U287 - U287
  • [8] Comparison of optical biometry and applanation ultrasound measurements of the axial length of the eye
    Nakhli, Fouad R.
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2014, 28 (04) : 287 - 291
  • [9] Evaluation of Axial Length Measurement of the Eye Using Partial Coherence Interferometry and Ultrasound in Cases of Macular Disease
    Kojima, Takashi
    Tamaoki, Akeno
    Yoshida, Norihiko
    Kaga, Tatsushi
    Suto, Chikako
    Ichikawa, Kazuo
    OPHTHALMOLOGY, 2010, 117 (09) : 1750 - 1754
  • [10] Accuracy and reproducibility of biometry using partial coherence interferometry
    Connors, R
    Boseman, P
    Olson, RJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02): : 235 - 238