Aqueous flow in the anterior chamber with angle-supported intraocular lens

被引:0
|
作者
Kumar, Ajay [1 ]
Babu, A. Benerji [1 ]
Flarence, M. R. [2 ]
机构
[1] Natl Inst Technol Warangal, Dept Math, Warangal, Telangana, India
[2] Kakatiya Med Collage, Dept Opthalmol, Warangal, India
关键词
HUMAN EYE; FLUID-MECHANICS; HUMOR FLOW; SIMULATION; MYOPIA; PREVALENCE;
D O I
10.1063/5.0254470
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Inserting of anterior chamber phakic intraocular lenses are emerging as a transformative option for vision correction, offering individuals with high myopia and thin corneas a safe and effective solution without compromising the natural lens. Implantation of a Z-shaped anterior chamber lens fourth generation (ZSAL-4) can change the typical flow patterns of aqueous humor. To study this flow patterns, we utilized advanced computational fluid dynamics using Ansys Fluent. This method originated as a novel approach to measuring fluid flow and comprehending the complex mechanics of human eye. This research displays the effect of anterior chamber depth and White to White on velocity, pressure, wall shear stress, skin friction coefficient, strain rate, stream function, and pathlines.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Iris atrophy and erosion caused by an anterior-chamber angle-supported phakic intraocular lens
    Akil, Handan
    Dhubhghaill, Sorcha Ni
    Tassignon, Marie-Jose
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (01) : 226 - 229
  • [2] Rotation Stability of the Cachet Angle-Supported Phakic Intraocular Lens
    Kermani, Omid
    Oberheide, Uwe
    Gerten, Georg
    JOURNAL OF REFRACTIVE SURGERY, 2013, 29 (06) : 390 - 394
  • [3] Intraocular stability of an angle-supported phakic intraocular lens with changes in pupil diameter
    Alio, Jorge L.
    Pinero, David P.
    Sala, Esperanza
    Amparo, Francisco
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (09) : 1517 - 1522
  • [4] Visual and aberrometric outcomes in eyes with an angle-supported phakic intraocular lens
    Toso, Antonio
    Morselli, Simonetta
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (09) : 1590 - 1594
  • [5] Laser in situ keratomileusis following the implantation of an angle-supported phakic intraocular lens
    Fernandez-Vigo Escribano, Cristina
    Macarro Merino, Ana
    Ignacio Fernandez-Vigo, Jose
    Fernandez-Vigo Lopez, Jose
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [6] Phakic Iris-Fixated Intraocular Lens Placement in the Anterior Chamber: Effects on Aqueous Flow
    Repetto, Rodolfo
    Pralits, Jan O.
    Siggers, Jennifer H.
    Soleri, Paolo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (05) : 3061 - 3068
  • [7] Anterior Segment Optical Coherence Tomography of Long-Term Phakic Angle-Supported Intraocular Lenses
    Alio, Jorge L.
    Abbouda, Alessandro
    Pena-Garcia, Pablo
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (05) : 894 - 901
  • [8] Bilensectomy: Safety and Visual Outcomes in Angle-Supported, Iris-Fixated, and Posterior Chamber Phakic Intraocular Lenses
    Vargas, Veronica
    Alio, Jorge L.
    del Barrio, Jorge L. Alio
    Canto-Cerdan, Mario
    Barraquer, Rafael I.
    Duch, Francisco
    Marinho, Antonio
    JOURNAL OF REFRACTIVE SURGERY, 2023, 39 (02) : 128 - +
  • [9] The Correction of Aphakia Using Anterior Chamber Intraocular Lens
    Moschos, Marilita M.
    Nitoda, Eirini
    IN VIVO, 2016, 30 (06): : 733 - 738
  • [10] A Mechanistic Model of Aqueous Humor Flow to Study Effects of Angle Closure on Intraocular Pressure
    Murgoitio-Esandi, Javier
    Xu, Benjamin Y.
    Song, Brian J.
    Zhou, Qifa
    Oberai, Assad A.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2023, 12 (01):