A comparative study of SPE- and DLLME-based methods for the determination of opioids and benzodiazepines in urine samples using LC-MS/MS

被引:1
作者
Cliville-Cabre, Pol [1 ]
Rosendo, Luana M. [2 ]
Borrull, Francesc [1 ]
Aguilar, Carme [1 ]
Calull, Marta [1 ]
机构
[1] Univ Rovira i Virgili, Dept Analyt Chem & Organ Chem, Sescelades Campus,Marcelli Domingo 1, Tarragona 43007, Spain
[2] Univ Beira Interior CICS UBI, Fac Ciencias Saude, Ctr Invest Ciencias Saude, P-6200506 Covilha, Portugal
关键词
LC-MS/MS; Benzodiazepines; Opioids; Urine; SPE; DLLME; Green analytical chemistry; LIQUID-LIQUID MICROEXTRACTION; SOLID-PHASE EXTRACTION; TANDEM MASS-SPECTROMETRY; DRUGS; ABUSE; METABOLITES; PLASMA; SALIVA; QUANTITATION; CHEMISTRY;
D O I
10.1016/j.microc.2024.112354
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of drugs of abuse has been gaining increasing attention among the scientific community as drug consumption is considered a major global public health issue. Opioids and benzodiazepines are among the most widely consumed drugs worldwide. Analytical methods for their determination, particularly in urine matrices, primarily rely on chromatographic techniques. However, due to the complexity of the matrix and the low concentration levels at which these drugs are usually present (in the ng/L or mu g/L range), efficient sample pre-treatment strategies are essential. This step is of significant importance in the development of environmentally friendly analytical methods. For this reason, in recent years, pre-treatment techniques have been developed based on green analytical chemical principles to address this need. In this context, we present a comparative study of solid phase extraction (SPE) and dispersive liquid-liquid microextraction (DLLME) for the determination of a group of benzodiazepines and opioids in urine samples using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). The method, based on SPE, was developed using ExtraBond SCX as the sorbent and 7 mL of 5 % of NH4OH in methanol as the elution solvent, yielding recoveries ranging from 9 to 107 %. The DLLME method used 200 mu L of chloroform and 500 mu L of ethyl acetate as extractant and dispersant solvents, respectively, achieving recoveries between 14 and 86 %. The DLLME strategy proved to be greener than the SPE method in line with the principles of green analytical chemistry (GAC), as it required lower volumes of solvents, a shorter extraction time, and less energy consumption than the SPE method. Both methods were validated using urine matrices and subsequently applied to 11 urine specimens from women participating in detoxification programmes, confirming the suitability of these methods in toxicological and forensic analyses. The results showed that methadone and diazepam were the most frequently determined compounds, and a trend of polyconsumption was observed in most of the samples.
引用
收藏
页数:12
相关论文
共 61 条
  • [31] Development of an in-house mixed-mode solid-phase extraction for the determination of 16 basic drugs in urine by High Performance Liquid Chromatography-Ion Trap Mass Spectrometry
    Musile, Giacomo
    Cenci, Lucia
    Piletska, Elena
    Gottardo, Rossella
    Bossi, Alessandra M.
    Bortolotti, Federica
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2018, 1560 : 10 - 18
  • [32] National Institute on Drug Abuse, ABOUT US
  • [33] Gas Chromatography-Mass Spectrometry Method for the Quantitative Identification of 23 New Psychoactive Substances in Blood and Urine
    Nisbet, Lorna A.
    Wylie, Fiona M.
    Logan, Barry K.
    Scott, Karen S.
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2019, 43 (05) : 346 - 352
  • [34] Simultaneous Separation of Eight Benzodiazepines in Human Urine Using Field-Amplified Sample Stacking Micellar Electrokinetic Chromatography
    Oledzka, Ilona
    Kulinska, Zofia
    Prahl, Adam
    Baczek, Tomasz
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2015, 39 (06) : 436 - 443
  • [35] Homemade Pipette Tip Solid-Phase Extraction for the Simultaneous Determination of 40 Drugs of Abuse in Urine by Liquid Chromatography-Tandem Mass Spectrometry
    Pascual-Caro, Sergi
    Borrull, Francesc
    Calull, Marta
    Aguilar, Carme
    [J]. SEPARATIONS, 2022, 9 (09)
  • [36] Recent chromatographic and electrophoretic based methods for determining drugs of abuse in urine and oral fluid: A review from 2018 to June 2021
    Pascual-Caro, Sergi
    Borrull, Francesc
    Calull, Marta
    Aguilar, Carme
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2022, 156
  • [37] Development of a Liquid Chromatography-Tandem Mass Spectrometry Method for the Simultaneous Determination of 40 Drugs of Abuse in Human Urine: Application to Real Cases
    Pascual-Caro, Sergi
    Borrull, Francesc
    Aguilar, Carme
    Calull, Marta
    [J]. JOURNAL OF ANALYTICAL TOXICOLOGY, 2023, 47 (01) : 33 - 42
  • [38] AGREE-Analytical GREEnness Metric Approach and Software
    Pena-Pereira, Francisco
    Wojnowski, Wojciech
    Tobiszewski, Marek
    [J]. ANALYTICAL CHEMISTRY, 2020, 92 (14) : 10076 - 10082
  • [39] Pichini S, 1999, MASS SPECTROM REV, V18, P119, DOI 10.1002/(SICI)1098-2787(1999)18:2<119::AID-MAS2>3.0.CO
  • [40] 2-Z