Experimental study on the shear reinforcement contribution to punching shear resistance in flat slabs

被引:0
作者
Procopio, Hermes B. [1 ]
Marques, Marilia G. [2 ]
Liberati, Elyson A. P. [3 ]
Trautwein, Leandro M. [1 ]
机构
[1] Univ Estadual Campinas, Sch Civil Engn Architecture & Urban Design, Campinas, SP, Brazil
[2] Univ Fed Vicosa, Inst Exact & Technol Sci, Rio Paranaiba, MG, Brazil
[3] Univ Estadual Maringa, Civil Engn Dept, Maringa, Parana, Brazil
关键词
flat slabs; openings; punching shear; shear reinforcement; OPENING SIZE; CONNECTIONS; STRENGTH; BEHAVIOR; LOCATION;
D O I
10.1002/suco.202400220
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
With the growth of the adoption of flat slabs as a structural system in the usual reinforced concrete projects and the need for openings in slabs for the passage of electrical and hydraulic installations, it is necessary to thoroughly study the influence of such openings on the punching strength of slabs. In this paper, the influence of openings in punching shear resistance was investigated by testing five interior slab-column connections 2400 mm square and 160 mm thick, with rectangular columns and with and without shear reinforcement. The openings were adjacent to the sides of rectangular supports and had a diameter of 100 mm. The results of cracking and ultimate loads, vertical displacements, and flexural reinforcement strains were analyzed, and the test results were compared with responses predicted from the normative instructions. All slabs with shear reinforcement, with or without openings, failed by crossing the shear reinforcement (Internal Punching Shear). The use of shear reinforcement in slabs with openings showed that the ultimate punching load increased by 25% when compared to the slab without openings and shear reinforcement.
引用
收藏
页数:19
相关论文
共 30 条
[1]   Punching shear strength of waffle flat slabs with opening adjacent to elongated columns [J].
Aguiar, Amaury ;
Oliveira, Denio ;
Reis, Luciano ;
Nzambi, Aaron .
ENGINEERING STRUCTURES, 2021, 243
[2]  
AlShammari HH., 2011, J Eng, V17, P218, DOI DOI 10.31026/J.ENG.2011.02.03
[3]  
American Concrete Institute, 2019, ACI 318R19: Building code requirements for structural concrete and commentary
[4]   Effect of opening size and location on punching shear behaviour of two-way RC slabs [J].
Anil, Ozgur ;
Kina, Tolga ;
Salmani, Vahed .
MAGAZINE OF CONCRETE RESEARCH, 2014, 66 (18) :955-966
[5]  
[Anonymous], 2023, Brazilian Association of Technical Standards
[6]  
[Anonymous], 2004, Design of Concrete Structures- Part 1.1: General Rules and Rules for Buildings
[7]   Investigation of the effect of openings of interior reinforced concrete flat slabs [J].
Balomenos, Georgios P. ;
Genikomsou, Aikaterini S. ;
Polak, Maria A. .
STRUCTURAL CONCRETE, 2018, 19 (06) :1672-1681
[8]  
Borges LLJ, 2013, ACI STRUCT J, V110, P547
[9]   Non-Linear Analysis of Flat Slabs Prestressed with Unbonded Tendons Submitted to Punching Shear [J].
Brigo, Heraldo ;
Ashihara, Luana J. J. ;
Marques, Marilia G. ;
Liberati, Elyson A. P. .
BUILDINGS, 2023, 13 (04)
[10]  
Comit EuroInternational du Bton, 1993, CEBFIP model code 1990: design code