Real-Time EMG Decomposition Across Neural Excitation Levels Using Dual Self-Attention Residual Network

被引:0
作者
Li, Yixin [1 ,2 ]
Xu, Guanghua [1 ,2 ]
Zhang, Kai [3 ]
Wang, Gang [4 ]
Zheng, Yang [1 ,2 ]
机构
[1] Xi An Jiao Tong Univ, Inst Engn & Med Interdisciplinary Studies, Sch Mech Engn, Xian 710049, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Mech Engn, State Key Lab Mfg Syst Engn, Xian 710049, Peoples R China
[3] Univ Texas Hlth Sci Ctr, McGovern Med Sch, Faillace Dept Psychiat & Behav Sci, Houston, TX 77030 USA
[4] Xi An Jiao Tong Univ, Inst Biomed Engn, Sch Life Sci & Technol, Key Lab Biomed Informat Engn,Minist Educ, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Electromyography; Vectors; Fingers; Force; Muscles; Feature extraction; Real-time systems; Decoding; Data mining; Training; Dual self-attention residual network; fast independent component analysis (FastICA); force prediction; nonstationary EMG; real-time electromyogram (EMG) decomposition; MOTOR UNITS; MUSCLE; DENSITY; IDENTIFICATION; ORGANIZATION; RECRUITMENT; ORDER;
D O I
10.1109/TIM.2025.3551898
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Motor unit (MU) discharge information extracted via real-time electromyogram (EMG) decomposition shows superiority in dexterous finger motion decoding. The variation of excitation levels can, however, lead to MU recruitment/de-recruitment, resulting in nonstationary EMG activities and then degraded decomposition and decoding performance; therefore, a novel online decomposition approach based on the multiple separation vector strategy was developed in this study. First, the separation vectors corresponding to different excitation levels were extracted offline via the fast independent component analysis (FastICA) algorithm and then merged to construct the separation vector pool for each MU via a previous MU action potential classification network. Under the online condition, a dual self-attention residual network was proposed to identify the excitation level, and the separation vectors were alternated correspondingly [termed alternating strategy (AS) method]. The conventional method that always used a fixed separation (FS) vector was compared. The 30-min synthetic EMG and the 15-min experiment EMG with the neural drive and the contraction strength, respectively, varying between 0% and 45% maximum voluntary contraction (MVC) were used. The experiment involved dexterous multifinger extension with isometric contractions. The results showed that the AS method obtained a higher spike consistency (87.55% +/- 3.75 % versus 84.05% +/- 4.11 %) with the true spike trains using the synthetic EMG and improved force prediction performance using the experiment EMG, i.e., a higher correlation ( R-2 : 0.82 +/- 0.06 versus 0.76 +/- 0.07 ) and a lower prediction error root-mean-square error (RMSE): 8.87% +/- 1.53 % versus 13.61%MVC +/- 0.92 %MVC) compared with the FS method. Further development of the proposed method could potentially provide a robust humanmachine interface for dexterous finger force prediction in realistic applications.
引用
收藏
页数:12
相关论文
共 39 条
  • [1] Study of J/ψ decays into ηK*0(K)over-bar*0 BES Collaboration
    Ablikim, M.
    Bai, J. Z.
    Bai, Y.
    Ban, Y.
    Cai, X.
    Chen, H. F.
    Chen, H. S.
    Chen, H. X.
    Chen, J. C.
    Chen, Jin
    Chen, X. D.
    Chen, Y. B.
    Chu, Y. P.
    Dai, Y. S.
    Deng, Z. Y.
    Du, S. X.
    Fang, J.
    Fu, C. D.
    Gao, C. S.
    Gao, Y. N.
    Gu, S. D.
    Gu, Y. T.
    Guo, Y. N.
    Guo, Z. J.
    Harris, F. A.
    He, K. L.
    He, M.
    Heng, Y. K.
    Hu, H. M.
    Hu, T.
    Huang, G. S.
    Huang, X. T.
    Huang, Y. P.
    Ji, X. B.
    Jiang, X. S.
    Jiao, J. B.
    Jin, D. P.
    Jin, S.
    Li, G.
    Li, H. B.
    Li, J.
    Li, L.
    Li, R. Y.
    Li, W. D.
    Li, W. G.
    Li, X. L.
    Li, X. N.
    Li, X. Q.
    Liang, Y. F.
    Liu, B. J.
    [J]. PHYSICS LETTERS B, 2010, 685 (01) : 27 - 32
  • [2] Recruitment order of motor units in human vastus lateralis muscle is maintained during fatiguing contractions
    Adam, A
    De Luca, CJ
    [J]. JOURNAL OF NEUROPHYSIOLOGY, 2003, 90 (05) : 2919 - 2927
  • [3] Adaptive Real-Time Identification of Motor Unit Discharges From Non-Stationary High-Density Surface Electromyographic Signals
    Chen, Chen
    Ma, Shihan
    Sheng, Xinjun
    Farina, Dario
    Zhu, Xiangyang
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (12) : 3501 - 3509
  • [4] Hand gesture recognition based on motor unit spike trains decoded from high-density electromyography
    Chen, Chen
    Yu, Yang
    Ma, Shihan
    Sheng, Xinjun
    Lin, Chuang
    Farina, Dario
    Zhu, Xiangyang
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 55 (55)
  • [5] A Novel Framework Based on FastICA for High Density Surface EMG Decomposition
    Chen, Maoqi
    Zhou, Ping
    [J]. IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2016, 24 (01) : 117 - 127
  • [6] Continuous motion finger joint angle estimation utilizing hybrid sEMG-FMG modality driven transformer-based deep learning model
    Chen, Zhouping
    Wang, Hong
    Chen, Haonan
    Wei, Tao
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 85
  • [7] Independent component analysis based algorithms for high-density electromyogram decomposition: Experimental evaluation of upper extremity muscles
    Dai, Chenyun
    Hu, Xiaogang
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2019, 108 : 42 - 48
  • [8] Origins of Common Neural Inputs to Different Compartments of the Extensor Digitorum Communis Muscle
    Dai, Chenyun
    Shin, Henry
    Davis, Bradley
    Hu, Xiaogang
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [9] COMMON DRIVE OF MOTOR UNITS IN REGULATION OF MUSCLE FORCE
    DE LUCA, CJ
    ERIM, Z
    [J]. TRENDS IN NEUROSCIENCES, 1994, 17 (07) : 299 - 305
  • [10] Man/machine interface based on the discharge timings of spinal motor neurons after targeted muscle reinnervation
    Farina, Dario
    Vujaklija, Ivan
    Sartori, Massimo
    Kapelner, Tamas
    Negro, Francesco
    Jiang, Ning
    Bergmeister, Konstantin
    Andalib, Arash
    Principe, Jose
    Aszmann, Oskar C.
    [J]. NATURE BIOMEDICAL ENGINEERING, 2017, 1 (02):