Synchronized Contrast-Enhanced 4DCT Simulation for Target Volume Delineation in Abdominal SBRT

被引:0
|
作者
Faccenda, Valeria [1 ]
Panizza, Denis [1 ,2 ]
Niespolo, Rita Marina [3 ]
Colciago, Riccardo Ray [2 ]
Rossano, Giulia [2 ,3 ]
De Sanctis, Lorenzo [2 ,3 ]
Gandola, Davide [4 ]
Ippolito, Davide [2 ,4 ]
Arcangeli, Stefano [2 ,3 ]
De Ponti, Elena [1 ,2 ]
机构
[1] Fdn IRCCS San Gerardo dei Tintori, Med Phys Dept, I-20900 Monza, Italy
[2] Univ Milano Bicocca, Sch Med & Surg, I-20126 Milan, Italy
[3] Fdn IRCCS San Gerardo dei Tintori, Radiat Oncol Dept, I-20900 Monza, Italy
[4] Fdn IRCCS San Gerardo dei Tintori, Diagnost Radiol Dept, I-20900 Monza, Italy
关键词
contrast-enhanced imaging; abdominal stereotactic radiotherapy; target volume delineation; respiratory motion management; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; BODY RADIATION-THERAPY; HEPATOCELLULAR-CARCINOMA; AORTIC ENHANCEMENT; PANCREATIC-CANCER; CT SIMULATION; DYNAMIC CT; LIVER; INJECTION; RADIOTHERAPY;
D O I
10.3390/cancers16234066
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background/Objectives: To present the technical aspects of contrast-enhanced 4DCT (ce4DCT) simulation for abdominal SBRT. Methods: Twenty-two patients underwent two sequential 4DCT scans: one baseline and one contrast-enhanced with personalized delay time (tdelay) calculated to capture the tumor in the desired contrast phase, based on diagnostic triple-phase CT. The internal target volume (ITV) was delineated on ten contrast phases, and a panel of three experts qualitatively evaluated tumor visibility. Aortic HU values were measured to refine the tdelay for subsequent patients. The commonly used approach of combining triple-phase CT with unenhanced 4DCT was simulated, and differences in target delineation were evaluated by volume, centroid shift, Dice and Jaccard indices, and mean distance agreement (MDA). The margins required to account for motion were calculated. Results: The ce4DCT acquisitions substantially improved tumor visibility over the entire breathing cycle in 20 patients, according to the experts' unanimous evaluation. The median contrast peak time was 54.5 s, and the washout plateau was observed at 70.3 s, with mean peak and plateau HU values of 292 +/- 59 and 169 +/- 25. The volumes from the commonly used procedure (ITV2) were significantly smaller than the ce4DCT volumes (ITV1) (p = 0.045). The median centroid shift was 4.7 mm. The ITV1-ITV2 overlap was 69% (Dice index), 53% (Jaccard index), and 2.89 mm (MDA), with the liver volumes showing significantly lower indices compared to the pancreatic volumes (p <= 0.011). The margins required to better encompass ITV1 were highly variable, with mean values >= 4 mm in all directions except for the left-right axis. Conclusions: The ce4DCT simulation was feasible, resulting in optimal tumor enhancement with minimal resource investment, while significantly mitigating uncertainties in SBRT planning by addressing poor visibility and respiratory motion. Triple-phase 3DCT with unenhanced 4DCT led to high variability in target delineation, making the isotropic margins ineffective.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] 4DCT Simulation With Synchronized Contrast Injection in Liver SBRT Patients
    Helou, Joelle
    Karotki, Aliaksandr
    Milot, Laurent
    Chu, William
    Erler, Darby
    Chung, Hans T.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (01) : 55 - 59
  • [2] 4DCT simulation with synchronized contrast injection of liver SBRT patients
    Karotki, A.
    Milot, L.
    Chu, W.
    Karol, R.
    Erler, D.
    Chung, H. T.
    MEDICAL PHYSICS, 2014, 41 (08) : 10 - 10
  • [3] Triphasic contrast enhanced CT simulation with bolus tracking for pancreas SBRT target delineation
    Godfrey, Devon J.
    Patel, Bhavik N.
    Adamson, Justus D.
    Subashi, Ergys
    Salama, Joseph K.
    Palta, Manisha
    PRACTICAL RADIATION ONCOLOGY, 2017, 7 (06) : E489 - E497
  • [4] Daily 4DCT Based Evaluation of Treatment Volume Variations for Lung SBRT
    Wu, H.
    Ye, J. S.
    MEDICAL PHYSICS, 2024, 51 (10) : 7914 - 7914
  • [5] Impact of Respiratory Velocity On Target Volume Using 4DCT
    Nakamura, M.
    Narita, Y.
    Matsugi, K.
    Matsuo, Y.
    Nakata, M.
    Mizowaki, T.
    Hiraoka, M.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [6] Selection of External Surrogate for 4DCT Sorting: Does It Impact Target Delineation?
    Glide-Hurst, C.
    Bellon, M.
    Chetty, I.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [7] Overlap Volume Analysis Using 4DCT: Implications for Gating in SBRT of the Lung and Pancreas
    Yang, W.
    Mirhadi, A.
    Tuli, R.
    Hakimian, B.
    Yong, Y.
    Sandler, H.
    Fraass, B. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S878 - S879
  • [8] Onet: Contrast-enhanced CT assisted automatic clinical target volume delineation of prostate cancer
    Wan, Luping
    Jiang, Yin
    Wu, Hao
    Zhao, Wei
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3118 - S3120
  • [9] Importance of 4DCT for Target Volume Definition in Stereotactic Lung Radiotherapy
    Goksel, E.
    Cone, D.
    Tezcanli, E.
    Kucucuk, H.
    Senkesen, O.
    Yilmaz, M.
    Garipagaoglu, M.
    Aslay, I.
    Sengoz, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 172 - 172
  • [10] New tools and methodology for stereotactic body radiotherapy (SBRT) simulation using 4DCT
    Hampton, C. J.
    Kearns, W. T.
    Hinson, W. H.