Comparison of recovery times by using bispectral index monitoring versus end-tidal agent concentration monitoring in patients undergoing inhalational general anaesthesia

被引:0
作者
Chaudhuri, Shalini [1 ]
Banerjee, Sandipan [1 ]
Chattopadhyay, Uddalak [1 ]
Hussain, Syed S. [1 ]
机构
[1] Homi Bhabha Canc Hosp, Mahamana Pandit Madan Mohan Malviya Canc Ctr, Dept Anaesthesiol Crit Care & Pain, Varanasi, Uttar Pradesh, India
关键词
Anaesthesia recovery period; consciousness monitors; sevoflurane; AWARENESS; SURGERY;
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Aims: End-tidal anaesthetic gas concentration (ETAG) and bispectral index (BIS) are both used to monitor depth of anaesthesia. Maintaining an accurate depth of anaesthesia helps in early post-operative recovery. This study compared the recovery times from sevoflurane-nitrous oxide anaesthesia using ETAG monitoring with BIS monitoring. Methods: Four hundred and two patients undergoing elective surgeries under sevoflurane- nitrous oxide anaesthesia were enroled in this double blinded parallel group prospective randomised trial and allocated into two groups. The depth of anaesthesia was monitored using BIS in BIS group (n = 202) and end-tidal sevoflurane concentration (EtSevo) in ETAG group (n = 200). The time to extubation and recovery were compared between the groups. Parametric, non-parametric and categorical variables were compared using Student's 't' test, Wilcoxon's rank sum test and Chi-square test, respectively. Results: Time to extubation (min) [BIS group - 10, 5; ETAG group - 10, 5 (median, inter-quartile range, IQR), P = 0.32] and time to recovery (min) [BIS group - 14, 6; ETAG group - 13.5, 7 (median, IQR), P = 0.34] did not differ significantly between the two groups. The EtSevo concentration (vol%) was significantly higher in the BIS group at 5 min [BIS group - 1.2, 0.4; ETAG group - 1.0, 0.4 (median, IQR), P < 0.001], 30 min [BIS group - 1.1, 0.4; ETAG group - 1.0, 0.3 (median, IQR), P = 0.002] and 120 min [BIS group - 1.11 +/- 0.28; ETAG group - 0.96 +/- 0.27 (mean +/- standard deviation), P = 0.014] after induction of anaesthesia. Conclusions: BIS and ETAG monitoring are associated with comparable recovery profiles. ETAG monitoring is associated with significantly less sevoflurane consumption.
引用
收藏
页码:S161 / S168
页数:8
相关论文
共 17 条
  • [1] Impact of bispectral index monitoring on fast tracking of gynecologic patients undergoing laparoscopic surgery
    Ahmad, S
    Yilmaz, M
    Marcus, RJ
    Glisson, S
    Kinsella, A
    [J]. ANESTHESIOLOGY, 2003, 98 (04) : 849 - 852
  • [2] Anesthesia awareness and the bispectral index
    Avidan, Michael S.
    Zhang, Lini
    Burnside, Beth A.
    Finkel, Kevin J.
    Searleman, Adam C.
    Selvidge, Jacqueline A.
    Saager, Leif
    Turner, Michelle S.
    Rao, Srikar
    Bottros, Michael
    Hantler, Charles
    Jacobsohn, Eric
    Evers, Alex S.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2008, 358 (11) : 1097 - 1108
  • [3] Prevention of Intraoperative Awareness in a High-Risk Surgical Population
    Avidan, Michael S.
    Jacobsohn, Eric
    Glick, David
    Burnside, Beth A.
    Zhang, Lini
    Villafranca, Alex
    Karl, Leah
    Kamal, Saima
    Torres, Brian
    O'Connor, Michael
    Evers, Alex S.
    Gradwohl, Stephen
    Lin, Nan
    Palanca, Ben J.
    Mashour, George A.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (07) : 591 - 600
  • [4] Basar H, 2003, EUR J ANAESTH, V20, P396
  • [5] Correlation between bispectral index, end-tidal anaesthetic gas concentration and difference in inspired-end-tidal oxygen concentration as measures of anaesthetic depth in paediatric patients posted for short surgical procedures
    Dias, Raylene
    Dave, Nandini
    Agrawal, Barkha
    Baghele, Aarti
    [J]. INDIAN JOURNAL OF ANAESTHESIA, 2019, 63 (04) : 277 - 283
  • [6] Ibraheim Osama, 2008, Middle East Journal of Anesthesiology, V19, P819
  • [7] Jain Neena, 2016, Anesth Essays Res, V10, P591
  • [8] Medical Advisory Secretariat, 2004, Ont Health Technol Assess Ser, V4, P1
  • [9] Enhanced recovery after surgery (ERAS).... still a distant speck on the horizon
    Mehdiratta, Lalit
    Mishra, Sandeep Kumar
    Vinayagam, Stalin
    Nair, Abhijit
    [J]. INDIAN JOURNAL OF ANAESTHESIA, 2021, 65 (02) : 93 - 96
  • [10] Sevoflurane titration using bispectral index decreases postoperative vomiting in phase II recovery after ambulatory surgery
    Nelskylä, KA
    Yli-Hankala, AM
    Puro, PH
    Korttila, KT
    [J]. ANESTHESIA AND ANALGESIA, 2001, 93 (05) : 1165 - 1169