Colorimetric and fluorescence detection of Pb2+ by fluorescein derivative

被引:0
作者
Chaivisuthangkura, Tanchanok [1 ]
Boosamund, Natthara [1 ]
Asawutmangkul, Nahathai [1 ]
Khammee, Thongchai [2 ]
Jityuti, Benchawan [3 ]
Siangproh, Weena [3 ]
机构
[1] Srinakharinwirot Univ, Patumwan Demonstrat Sch, Bangkok 10330, Thailand
[2] Phranakhon Rajabhat Univ, Fac Sci & Technol, Dept Chem, Bangkok 10220, Thailand
[3] Srinakharinwirot Univ, Fac Sci, Dept Chem, Bangkok 10110, Thailand
关键词
Fluorescein; Lead; Metal ion; Naked eyes; Sustainable cities; ATOMIC-ABSORPTION-SPECTROMETRY; LEAD; PROBE; CHEMOSENSOR; QUINOLINE; CADMIUM; SENSOR;
D O I
10.1016/j.saa.2024.125373
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A simple and low cost method for rapid detection of Pb2+ was developed in this study using a simple fluorescent probe, biotin-4-fluorescein. The presence of Pb2+ induced the color change of fluorescein from yellow to pink which can be detected visually by naked eyes. The color change of biotin-4-fluorescein was not observed while testing with other metal ions, such as Fe3+, Cu2+, Ca2+, Co2+ and Cd2+, indicating the selectivity of fluorescein derivative with Pb2+. Moreover, the color change was observed at pH above 7.0, and the pink color got more intense when increasing pH. Adding EDTA, a chelating reagent, into the solution of biotin-4-fluorescein/Pb2+ resulted to the rebound of the color to the original color of free biotin-4-fluorescein. The fluorescence spectra of fluorescein decreased with increasing Pb2+concentration, and the quenching was enhanced at higher pH. The association constant (Ka) of 2.00 x 104 M-1 was calculated from the fluorescence spectra with the limit of detection (LOD) and the limit of quantitation (LOQ) of 1.38 x 10-5 M (2.86 ppm) and 4.61 x 10-5 M (9.55 ppm), respectively. Job's plot analysis indicated 2:1 ratio of binding interaction. Pb2+ in untreated wastewater was quantified for 24.99 ppm using this method. This quick analysis can be beneficial for the application of lead detection in real sample solutions, such as wastewater from industrial factories.
引用
收藏
页数:9
相关论文
共 25 条
  • [1] Phenazine containing indeno-furan based colorimetric and "on-off" fluorescent sensor for the detection of Cu2+ and Pb2+
    Aggarwal, Komal
    Khurana, Jitender M.
    [J]. JOURNAL OF LUMINESCENCE, 2015, 167 : 146 - 155
  • [2] A new ICT and CHEF based visible light excitable fluorescent probe easily detects in vivo Zn2+
    Aich, Krishnendu
    Goswami, Shyamaprosad
    Das, Sangita
    Das Mukhopadhyay, Chitrangada
    [J]. RSC ADVANCES, 2015, 5 (39) : 31189 - 31194
  • [3] A review on Rhodamine-based Schiff base derivatives: synthesis and fluorescent chemo-sensors behaviour for detection of Fe3+ and Cu2+ ions
    Alam, Md Zafer
    Khan, Salman. A. A.
    [J]. JOURNAL OF COORDINATION CHEMISTRY, 2023, 76 (3-4) : 371 - 402
  • [4] Bannon DI, 2001, CLIN CHEM, V47, P1703
  • [5] A SPECTROPHOTOMETRIC INVESTIGATION OF THE INTERACTION OF IODINE WITH AROMATIC HYDROCARBONS
    BENESI, HA
    HILDEBRAND, JH
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1949, 71 (08) : 2703 - 2707
  • [6] Modulating the selectivity of near-IR fluorescent probes toward various metal ions by judicious choice of aqueous buffer solutions
    Cheng, Tanyu
    Wang, Tao
    Zhu, Weiping
    Yang, Yangyang
    Zeng, Bubing
    Xu, Yufang
    Qian, Xuhong
    [J]. CHEMICAL COMMUNICATIONS, 2011, 47 (13) : 3915 - 3917
  • [7] A novel 2-(Hydroxymethyl)quinolin-8-ol-based selective and sensitive fluorescence probe for Cd2+ ion in water and living cells
    Dai, Yanpeng
    Yao, Kun
    Fu, Jiaxin
    Xue, Kun
    Yang, Li
    Xu, Kuoxi
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2017, 251 : 877 - 884
  • [8] A new fluorescent probe based on quinoline for detection of Al3+ and Fe3+ with "off-on-off" response in aqueous solution
    Dai, Yanpeng
    Liu, Xiaoyan
    Wang, Peng
    Fu, Jiaxin
    Yao, Kun
    Xu, Kuoxi
    [J]. RSC ADVANCES, 2016, 6 (102): : 99933 - 99939
  • [9] Simple bisthiocarbonohydrazones as sensitive, selective, colorimetric, and switch-on fluorescent chemosensors for fluoride anions
    Han, Feng
    Bao, Yuhui
    Yang, Zhigang
    Fyles, Thomas M.
    Zhao, Jianzhang
    Peng, Xiaojun
    Fan, Jiangli
    Wu, Yunkou
    Sun, Shiguo
    [J]. CHEMISTRY-A EUROPEAN JOURNAL, 2007, 13 (10) : 2880 - 2892
  • [10] Determination of Lead with a Copper-Based Electrochemical Sensor
    Kang, Wenjing
    Pei, Xing
    Rusinek, Cory A.
    Bange, Adam
    Haynes, Erin N.
    Heineman, William R.
    Papautsky, Ian