Development of a Deep Learning Model for Classification of Hepatic Steatosis from Clinical Standard Ultrasound

被引:0
|
作者
El Kaffas, Ahmed [1 ]
Bhatraju, Krishna Chaitanya [1 ,2 ]
Vo-Phamhi, Jenny M. [1 ,2 ]
Tiyarattanachai, Thodsawit [2 ,3 ]
Antil, Neha [2 ]
Negrete, Lindsey M. [2 ]
Kamaya, Aya [2 ]
Shen, Luyao [2 ]
机构
[1] Univ Calif San Diego, Sch Med, Dept Radiol, LA JOLLA, CA USA
[2] Stanford Univ, Sch Med, Dept Radiol, 300 Pasteur Dr H1307, Stanford, CA 94305 USA
[3] Stanford Univ, Sch Med, Dept Biomed Data Sci, Stanford, CA USA
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2025年 / 51卷 / 02期
关键词
Deep learning; Hepatic steatosis; Ultrasound; Grayscale; FATTY LIVER-DISEASE; QUANTIFICATION;
D O I
10.1016/j.ultrasmedbio.2024.09.020
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective: Early detection and monitoring of hepatic steatosis can help establish appropriate preventative measures against progression to more advanced disease. We aimed to develop a deep learning (DL) program for classification of hepatic steatosis from standard-of-care grayscale ultrasound (US) images. Methods: In this single-center retrospective study, we utilized grayscale US images from January 1, 2010, to October 23, 2022, labeled with magnetic resonance imaging (MRI) proton density fat fraction (MRI-PDFF) to develop a DL multi-instance program for differentiating normal (S0) from steatotic liver (S1/2/3) and normal/mild steatosis (S0/1) from moderate/severe steatosis (S2/3). Diagnostic performances were assessed with area under the receiver operating characteristic curves (AUC), sensitivity, specificity and balanced accuracy with 95% confidence interval (CI). Results: A total of 403 patients with 403 US exams were included: 171 (42%) were normal (S0: MRI-PDFF <5%), 154 (38%) had mild steatosis (S1: MRI-PDFF 5-17.4%), 29 (7%) had moderate steatosis (S2: MRI-PDFF >17.4%-22.1%) and 49 (12%) had severe steatosis (S3: MRI-PDFF >22.1%). The dataset was split to include 322 patients in train/validation and 81 patients in a holdout test set (kept blind). The S0 versus S1/2/3 model achieved 81.3% (95% CI 72.1-90.5) AUC, 81.1% (70.6-91.6) sensitivity, 71.4% (54.7-88.2) specificity and 76.3% (66.4-86.2) balanced accuracy. The S0/1 versus S2/3 model achieved 95.9% (89-100) AUC, 87.5% (71.3-100) sensitivity, 96.9% (92.7-100) specificity and 92.2% (83.8-100) balanced accuracy. A multi-class model achieved a sensitivity of 71.4% (54.7-88.2) for S0, 67.6% (52.5-82.7) for S1 and 87.5% (71.3-100) for S2/3; specificity for the same model was 81.1% (70.6-91.6) for S0, 77.3% (64.9-89.7) for S1 and 96.9% (92.7-100) for S2/3. Conclusion: Our DL program offered high sensitivity and accuracy in detecting and categorizing hepatic steatosis from standard-of-care ultrasound.
引用
收藏
页码:242 / 249
页数:8
相关论文
共 50 条
  • [1] A Deep Learning Approach for Hepatic Steatosis Estimation from Ultrasound Imaging
    Colantonio, Sara
    Salvati, Antonio
    Caudai, Claudia
    Bonino, Ferruccio
    De Rosa, Laura
    Pascali, Maria Antonietta
    Germanese, Danila
    Brunetto, Maurizia Rossana
    Faita, Francesco
    ADVANCES IN COMPUTATIONAL COLLECTIVE INTELLIGENCE (ICCCI 2021), 2021, 1463 : 703 - 714
  • [2] Clinical Value of Information Entropy Compared with Deep Learning for Ultrasound Grading of Hepatic Steatosis
    Chen, Jheng-Ru
    Chao, Yi-Ping
    Tsai, Yu-Wei
    Chan, Hsien-Jung
    Wan, Yung-Liang
    Tai, Dar-In
    Tsui, Po-Hsiang
    ENTROPY, 2020, 22 (09)
  • [3] COMPARATIVE STUDY OF RAW ULTRASOUND DATA REPRESENTATIONS IN DEEP LEARNING TO CLASSIFY HEPATIC STEATOSIS
    Sanabria, Sergio J.
    Pirmoazen, Amir M.
    Dahl, Jeremy
    Kamaya, Aya
    El Kaffas, Ahmed
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (10): : 2060 - 2078
  • [4] Ultrasound Versus Elastography in the Diagnosis of Hepatic Steatosis: Evaluation of Traditional Machine Learning Versus Deep Learning
    Marques, Rodrigo
    Santos, Jaime
    Andre, Alexandra
    Silva, Jose
    SENSORS, 2024, 24 (23)
  • [5] An analysis of hepatic steatosis based on radiomics and deep learning
    Zhang, Zheng
    Ge, Renbin
    Zhang, Lei
    Zhang, Chi
    Li, Xinghui
    Gu, Zhongze
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2020, 13 (10): : 7684 - 7690
  • [6] Joint segmentation and classification of hepatic lesions in ultrasound images using deep learning
    Ryu, Hwaseong
    Shin, Seung Yeon
    Lee, Jae Young
    Lee, Kyoung Mu
    Kang, Hyo-jin
    Yi, Jonghyon
    EUROPEAN RADIOLOGY, 2021, 31 (11) : 8733 - 8742
  • [7] Automatic Classification of Hepatic Cystic Echinococcosis Using Ultrasound Images and Deep Learning
    Wu, Miao
    Yan, Chuanbo
    Wang, Xiaorong
    Liu, Qian
    Liu, Zhihua
    Song, Tao
    JOURNAL OF ULTRASOUND IN MEDICINE, 2022, 41 (01) : 163 - 174
  • [8] Joint segmentation and classification of hepatic lesions in ultrasound images using deep learning
    Hwaseong Ryu
    Seung Yeon Shin
    Jae Young Lee
    Kyoung Mu Lee
    Hyo-jin Kang
    Jonghyon Yi
    European Radiology, 2021, 31 : 8733 - 8742
  • [9] Development and validation of multivariable quantitative ultrasound for diagnosing hepatic steatosis
    Sun Kyung Jeon
    Jeong Min Lee
    Soo Jin Cho
    Young-Hye Byun
    Jae Hwan Jee
    Mira Kang
    Scientific Reports, 13
  • [10] Development and validation of multivariable quantitative ultrasound for diagnosing hepatic steatosis
    Jeon, Sun Kyung
    Lee, Jeong Min
    Cho, Soo Jin
    Byun, Young-Hye
    Jee, Jae Hwan
    Kang, Mira
    SCIENTIFIC REPORTS, 2023, 13 (01)