Oral Endotracheal Intubation with Restricted Glottis View using C-MAC D Blade®: A Randomised Controlled Trial

被引:0
作者
Patel, Vaidarbhi rasikbhai [1 ]
Panchal, Nirali nimeshkumar [2 ]
Mehta, Sanket hirenbhai [3 ]
Chaudhari, M. A. D. H. A. V. I. SANjAY [3 ]
Pathak, Bhumika pradipkumar [3 ]
Shinde, Mayur kiran [4 ]
机构
[1] GMERS Med Coll, Dept Anaesthesiol, Navsari, Gujarat, India
[2] Pramukhswami Med Coll, Dept Anaesthesiol, Anand, Gujarat, India
[3] Bhaikaka Univ, Pramukhswami Med Coll, Dept Anaesthesiol, Anand, Gujarat, India
[4] Bharati Vidyapeeth Deemed Univ, Med Coll, Dept Community Med, Pune, Maharastra, India
关键词
Airway management; General anaesthesia; Intratracheal; Laryngoscopy; DIRECT LARYNGOSCOPY; VIDEO LARYNGOSCOPE; DIFFICULT INTUBATION; TRACHEAL INTUBATION; LARYNGEAL VIEW; VIDEOLARYNGOSCOPY; MANAGEMENT; GLIDESCOPE(R); GUIDELINES; SOCIETY;
D O I
10.7860/JCDR/2024/73543.20408
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The perspective of airway management has undergone a considerable transformation since the advent of Video Laryngoscopes (VL). VL has rapidly been accepted as an intubation tool in a variety of clinical scenarios. This heralds a wide array of VL models with their own strengths and weaknesses. The C-MAC D blade (R) is one such VL with an angulated blade that provides an excellent glottis view, but negotiating the Endotracheal Tube (ETT) past the glottis opening and into the trachea might be difficult. No study till date was done on the C-MAC D blade (R) with different glottis views for intubation. Aim: To compare the Total Time of Intubation (TTI) with restricted glottis view and full glottis view with C-MAC D blade (R) as the primary aim, along with the first attempt intubation rate and complications during intubation. Materials and Methods: The present prospective single-centre randomised controlled trial was conducted in the Department of Anaesthesiology, Shree Krishna Hospital, PSMC, Karamsad, Gujarat, India, from September 2021 to August 2022. A total of 42 patients were randomly divided into two groups: group-F (n=21), which had a full glottis view, and group-R (n=21), which had a restricted glottis view. Randomised glottis views were achieved with the C-MAC D blade (R) VL during oral endotracheal intubation in both groups. Video recordings of the intubations were made, and TTI, first attempt success rate and complications during intubation were noted. Statistical analysis was done with an independent sample t-test to compare the two groups of continuous variables using STATA version 14.2. Results: The mean age in group-F was 45.86 +/- 10.83 years and in group-R was 47.76 +/- 9.14 years. The male-to-female ratio in group-F was 10:11 and in group-R was 9:12. Overall, the first- attempt successful intubation rate with the C-MAC D blade (R) in both groups was 90.48%. However, it was higher in group-R (95.24%) compared to group-F (85.71%). TTI was less in group-R compared to group-F (36.19 +/- 11.11 vs 45 +/- 15.89 seconds, p-value=0.0438). Group-R had lower incidence of postoperative sore throat (14.29% vs 57.14%, p-value=0.004) compared to group-F. Conclusion: Total time of intubation was less with a restricted glottis view compared to a full glottis view with C-MAC D blade (R) VL. Additionally, the restricted view had a higher first attempt intubation rate. Postoperative sore throat was significantly lower in the restricted view, with a lesser incidence of oropharyngeal trauma compared to the full glottis view.
引用
收藏
页码:UC24 / UC28
页数:5
相关论文
共 50 条
  • [1] Increased First Pass Success with C-MAC Videolaryngoscopy in Prehospital Endotracheal Intubation-A Randomized Controlled Trial
    Macke, Christian
    Gralla, Felix
    Winkelmann, Marcel
    Clausen, Jan-Dierk
    Haertle, Marco
    Krettek, Christian
    Omar, Mohamed
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (09) : 1 - 9
  • [2] Comparison of the C-MAC D-Blade videolaryngoscope and direct laryngoscope in pediatric patients: Randomized controlled trial
    Hajiyeva, Konul
    Can, Ozlem Selvi
    Baytas, Volkan
    Guclu, Cigdem Yildirim
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2021, 27 (04): : 421 - 426
  • [3] Indirect videolaryngoscopy with C-MAC D-Blade and GlideScope: a randomized, controlled comparison in patients with suspected difficult airways
    Serocki, G.
    Neumann, T.
    Scharf, E.
    Doerges, V.
    Cavus, E.
    MINERVA ANESTESIOLOGICA, 2013, 79 (02) : 121 - 129
  • [4] Comparison of C-MAC® conventional blade, D-Blade™, and Macintosh laryngoscopes for endotracheal intubation in patients with simulated immobilization using manual in-line stabilization: A randomized trial
    Dabas, M.
    Gupta, M.
    Mohanan, S.
    Kaushik, P.
    Lall, R.
    JOURNAL OF POSTGRADUATE MEDICINE, 2024, 70 (03) : 149 - 153
  • [5] Comparison of Force Distribution during Laryngoscopy with the C-MAC D-BLADE and Macintosh-Style Blades: A Randomised Controlled Clinical Trial
    Schmutz, Axel
    Breddin, Ingo
    Draxler, Ramona
    Schumann, Stefan
    Spaeth, Johannes
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (09)
  • [6] C-MAC D-Blade vs Airtraq for Intubation with Manual Inline Axial Stabilisation- A Randomised Clinical Trial
    Mani, Nikitha
    Palanisamy, Nagalakshmi
    Zachariah, Mamie
    George, Sagiev Koshy
    Dsilva, Allen Aloysius
    Johns, Jemmie Rachel
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (01)
  • [7] Awake videolaryngoscopic orotracheal intubation in patients with laryngeal tumour using the C-MAC D-Blade
    Selvam, Selwin R.
    Jindal, Swati
    Anand, Lakesh K.
    Dawar, Manpreet Singh
    Dass, Arjun
    INDIAN JOURNAL OF ANAESTHESIA, 2022, 66 (08) : 579 - 584
  • [8] Comparison of cervical spine motion during intubation with a C-MAC D-Blade® and an LMA Fastrach®
    Ozkan, D.
    Altinsoy, S.
    Sayin, M.
    Dolgun, H.
    Ergil, J.
    Donmez, A.
    ANAESTHESIST, 2019, 68 (02): : 90 - 96
  • [9] Predictors of difficult videolaryngoscopy with GlideScope® or C-MAC® with D-blade: secondary analysis from a large comparative videolaryngoscopy trial
    Aziz, M. F.
    Bayman, E. O.
    Van Tienderen, M. M.
    Todd, M. M.
    Brambrink, A. M.
    BRITISH JOURNAL OF ANAESTHESIA, 2016, 117 (01) : 118 - 123
  • [10] Effect of Blade Size on the First-Pass Success Rate of Endotracheal Intubation Using the C-MAC Video Laryngoscope
    Park, Jeongyong
    Park, Goeun
    Kim, Da Seul
    Kim, Minha
    Heo, Sejin
    Jeong, Daun
    Chang, Hansol
    Lee, Se Uk
    Choi, Goosang
    Lee, Gun Tak
    Shin, Tae Gun
    Park, Jong Eun
    Hwang, Sung Yeon
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (22)