Label-Free Extended Gate Field-Effect Transistor for Sensing Microcystin-LR in Freshwater Samples

被引:2
作者
Nandanwar, Sondavid [1 ]
Lee, Songyi [1 ,2 ]
Park, Myeongkee [2 ]
Kim, Hak Jun [2 ]
机构
[1] Pukyong Natl Univ, Ind Convergence Bion Engn 4 0, Pusan 48513, South Korea
[2] Pukyong Natl Univ, Dept Chem, Pusan 48513, South Korea
关键词
EG-FET; DNA aptamer; cyanotoxins; carbon nanotube; microcystin; FABRICATION; NANOTUBES;
D O I
10.3390/s25051587
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, we developed a label-free biosensor based on aptamer-modified multi-walled carbon nanotube extended gate field-effect transistor (MWCNT-EG-FET) for easy and selective detection of microcystin-LR (MC-LR), a prominent cyanotoxin associated with liver damage, bleeding, and necrosis. EG-FET had two parts: a MOSFET and an extended-gate Au/SiO2 electrode, which serves as the sensitive membrane. A custom-designed DNA oligonucleotide (5-NH2-C6-AN6) was used as MC-LR-targeting aptamer (MCTA). MWCNTs were functionalized with MCTA and then stably fixed on the sensitive membrane. The detection of MC-LR in freshwater was effectively achieved within 5 min by assessing the variations in electrical resistance that occur due to the selective interactions between MC-LR and MCTA. The detection limit and analytical sensitivity of the biosensor for MC-LR were found to be 0.134 ng/mL and 0.024 ng/mL, respectively. The sensitive membrane could be readily discarded if damaged, eliminating the need to replace the main transducer MOSFET. The developed sensor exhibits features such as straightforward preparation, swift response, potential for miniaturization, and ease of use, making it an attractive candidate for future integrated lab-on-chip systems for MC-LR detection in freshwater environments.
引用
收藏
页数:12
相关论文
共 50 条
[41]   Impact of rapid thermal annealing on structural and sensing properties of Ni-Ti sensitive films for extended-gate field-effect transistor pH sensors [J].
Pan, Tung-Ming ;
Yang, Chih-Hsiang ;
Pang, See-Tong .
SURFACES AND INTERFACES, 2023, 39
[42]   Disturb-Free Writing Operation for Ferroelectric-Gate Field-Effect Transistor Memories With Intermediate Electrodes [J].
Horita, Susumu ;
Trinh, Bui Nguyen Quoc .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2009, 56 (12) :3090-3096
[43]   Electrically Reconfigurable Dual Metal-Gate Planar Field-Effect Transistor for Dopant-free CMOS [J].
Krauss, Tillmann ;
Wessely, Frank ;
Schwalke, Udo .
2016 13TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS & DEVICES (SSD), 2016, :681-686
[44]   High-Performance Proximity Sensors with Nanogroove-Template-Enhanced Extended-Gate Field-Effect Transistor Configuration [J].
Liu, Weilin ;
Niu, Yixue ;
Chen, Qiusong ;
Jiang, Hanxiao ;
Xu, Fan ;
Zhu, Guodong .
ADVANCED ELECTRONIC MATERIALS, 2019, 5 (12)
[45]   High performance extended gate field effect transistor-based pesticide sensing system with a planar microreference electrode [J].
Hsieh, Chia-Hsu ;
Ly, Le-Quyen ;
Su, Guan-Jie ;
Lin, Yu-Cheng ;
Huang, I-Yu .
2017 IEEE SENSORS, 2017, :1125-1127
[46]   Label-free DNA hybridization and denaturation detection by means of field-effect nanoplate SOI capacitors functionalized with gold nanoparticles [J].
Abouzar, M. H. ;
Pedraza, A. M. ;
Schoening, M. J. ;
Poghossian, A. .
EUROSENSORS XXIV CONFERENCE, 2010, 5 :918-921
[47]   Label-free attomolar detection of lactate based on radio frequency sputtered of nickel oxide thin film field effect transistor [J].
Majd, Samira Mansouri ;
Salimi, Abdollah ;
Astinchap, Bandar .
BIOSENSORS & BIOELECTRONICS, 2017, 92 :733-740
[48]   An Extended-Gate Field-Effect Transistor Applied to Resistive Divider Integrated With the Readout Circuit Using 180nm CMOS Process for Uric Acid Detection [J].
Kuo, Po-Yu ;
Chen, Yung-Yu ;
Lai, Wei-Hao ;
Chang, Chun-Hung .
IEEE SENSORS JOURNAL, 2021, 21 (18) :20229-20238
[49]   Characteristics of Extended-Gate Field-Effect Transistor (EGFET) Based on Porous n-Type (111) Silicon for Use in pH Sensors [J].
Ahmed, Naser M. ;
Kabaa, E. A. ;
Jaafar, M. S. ;
Omar, A. F. .
JOURNAL OF ELECTRONIC MATERIALS, 2017, 46 (10) :5804-5813
[50]   Laser-induced multi-doped graphene extended-gate field-effect transistor sensor for enhanced detection of cystatin C [J].
Yu, Wenbang ;
Chen, Xiaofen ;
Li, Xinjie ;
Wei, Zihan ;
Tang, Jing ;
Zhang, Min .
TALANTA, 2025, 282