Experimental study on seismic performance of seismic-damaged precast steel reinforced (recycled) concrete frame structure after strengthened and repaired

被引:2
作者
Chen, Yuliang [1 ,2 ,3 ,4 ]
Zhu, Zhen [1 ]
Wu, Huiqin [1 ,2 ,3 ,4 ]
Liu, Jie [1 ]
Zhu, Ling [1 ]
Ye, Peihuan [1 ,2 ,3 ,4 ]
机构
[1] Guangxi Univ Sci & Technol, Sch Civil Engn & Architecture, Liuzhou 545006, Peoples R China
[2] Guangxi Engn Res Ctr Safety Prevent & Control Asse, Liuzhou 545006, Peoples R China
[3] Key Lab Disaster Prevent & Mitigat Prestress Techn, Liuzhou 545006, Peoples R China
[4] Liuzhou Key Lab Green Adv Civil Engn Mat Applicat, Liuzhou 545006, Peoples R China
关键词
Strengthened in various ways; Earthquake damage; Prefabricated steel reinforced concrete frame; High strength steel wire cloth; Seismic performance; RC FRAMES; BEHAVIOR; COLUMNS; CAPACITY; JOINTS;
D O I
10.1016/j.jobe.2024.111156
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to understand the seismic performance and failure mechanism of the seismic-damaged prefabricated steel (recycled) concrete frame after strengthening and repairing, this paper uses four different strengthened methods, including carbon fiber reinforced polymer (CFRP), highstrength steel wire cloth (HSSWC), oblique support and enveloped steel jacket. Four seismicdamaged prefabricated steel (recycled) concrete frames were strengthened by single or composite strengthening, and low-cycle reciprocating failure tests were carried out on all frame specimens. The final failure mode of the reinforced specimens under simulated seismic load was observed. The seismic performance indexes such as load-displacement (P-Delta) hysteresis curve, skeleton curve, and stiffness degradation of each specimen before and after strengthening were compared and analyzed. The test results show that the strengthening methods used in this test can effectively restore the seismic performance of the seismic-damaged prefabricated steel (recycled) concrete frame. The specimens show a typical ductile failure mode, and the P-Delta hysteresis curve of the specimens is relatively full. For a single strengthened form, CFRP strengthened can more significantly restore and improve the ductility of the specimen than HSSWC strengthened, but the cumulative energy dissipation capacity of the specimen after HSSWC strengthened is stronger. The bearing capacity of the specimens after composite-strengthened is significantly improved, and the damage degree of the structure is reduced. The addition of oblique support and an enveloped steel jacket can provide greater lateral stiffness for the specimens and improve the failure mode of the specimens. The results of this paper can provide a scientific basis for the selection and design of strengthened methods for prefabricated steel-reinforced concrete structures after earthquake damage.
引用
收藏
页数:21
相关论文
共 84 条
[1]   Residual seismic performance of damaged reinforced concrete walls [J].
Alwashali, Hamood ;
Maeda, Masaki ;
Ogata, Yoshihiro ;
Aizawa, Naoyuki ;
Tsurugai, Kazuya .
ENGINEERING STRUCTURES, 2021, 243
[2]  
[Anonymous], 2013, GB 50367-2013
[3]  
[Anonymous], 2013, GB50011-2010
[4]  
[Anonymous], 1997, ASTM E.8M
[5]  
[Anonymous], 2013, T/CECS 146-2022
[6]  
[Anonymous], 2023, DB21/T 3696-2023
[7]  
[Anonymous], 2010, Code for design of concrete structures
[8]   Experimental study on the seismic performance of prefabricated frame piers [J].
Bao, Longsheng ;
Zhao, Jiakang ;
Teng, Fei ;
Bao, Yuyang ;
Zhao, Tongfeng ;
Yu, Ling .
STRUCTURES, 2023, 52 :651-665
[9]  
BETT BJ, 1988, ACI STRUCT J, V85, P499
[10]   Beam-column joints in continuous RC frames: Comparison between cast-in-situ and precast solutions [J].
Breccolotti, Marco ;
Gentile, Santino ;
Tommasini, Mauro ;
Materazzi, Annibale Luigi ;
Bonfigli, Massimo Federico ;
Pasqualini, Bruno ;
Colone, Valerio ;
Gianesini, Marco .
ENGINEERING STRUCTURES, 2016, 127 :129-144