Application of Enhanced Self-Adaptive Virtual Inertia Control for Efficient Frequency Control of Renewable Energy-Based Microgrid System Integrated With Electric Vehicles

被引:0
作者
Mishra, Sonalika [1 ]
Sahu, Preeti Ranjan [2 ]
Prusty, Ramesh Chandra [3 ]
Panda, Sidhartha [3 ]
Ustun, Taha Selim [4 ]
Onen, Ahmet [5 ]
机构
[1] Silicon Inst Technol, Dept Elect Engn, Sambalpur 763200, Odisha, India
[2] NIST Inst Sci & Technol, Dept Elect Engn, Brahmapur 761008, Odisha, India
[3] Veer Surendra Sai Univ Technol, Dept Elect Engn, Burla 768018, India
[4] Fukushima Renewable Energy Inst, Fukushima 9630298, Japan
[5] Univ Doha Sci & Technol, Coll Engn & Technol, Doha, Qatar
来源
IEEE ACCESS | 2025年 / 13卷
关键词
Frequency control; Power system stability; Damping; Renewable energy sources; State of charge; Energy storage; Electric vehicles; Synchronous generators; Stability criteria; Wind turbines; Self-adaptive enhanced virtual inertia control; electric vehicle; state of charge; enhanced virtual inertia control; STABILITY;
D O I
10.1109/ACCESS.2025.3548649
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The frequency control of an islanded microgrid (MG) is a challenging task due to the lack of system inertia as it is highly penetrated with renewable energy sources (RESs). Current work suggests overcoming this issue with an energy storage system (ESS)-based virtual inertia (VI) approach by providing appropriate proportional damping instead of a fixed value. In this study to overcome the frequency control issue, a fuzzy-based self-adaptive enhanced VI controller (SAEVIC) coordinated with electric vehicles (EV) is proposed. The controller is proposed to stabilize the system frequency and balance state of charge (SOC) of plugged-in electric vehicles (EVs). The performance of the proposed controller is justified in terms of frequency control over with/without conventional VI control, conventional enhanced VI control, and self-adaptive VI control. The system frequency and SOC signal are considered for the control action of the proposed controller. The impact of EV integration on the system frequency dynamics is tested. The validation of the proposed controller is carried out with a system injected with stochastic disturbances, high and low levels of renewable energies, denial of service attacks on renewable energy, and disturbed operating conditions with varied internal parameters. It is noticed that with the SAEVIC approach, the overshoot (OS)-11.40%, undershoot (US)- 46.46%, settling time (ST)-98.6% and fitness value-10.27% are decreased as compared to conventional enhanced VI approach under Stochastic variations of wind, PV, and multi-step load disturbance of MG system.
引用
收藏
页码:43520 / 43531
页数:12
相关论文
共 40 条
  • [1] Optimal PI controller based PSO optimization for PV inverter using SPWM techniques
    Abdolrasol, Maher G. M.
    Hannan, M. A.
    Hussain, S. M. Suhail
    Ustun, Taha Selim
    [J]. ENERGY REPORTS, 2022, 8 : 1003 - 1011
  • [2] Alhejaj SM, 2016, 2016 INTERNATIONAL CONFERENCE FOR STUDENTS ON APPLIED ENGINEERING (ICSAE), P254, DOI 10.1109/ICSAE.2016.7810198
  • [3] A New Frequency Control Strategy in an Islanded Microgrid Using Virtual Inertia Control-Based Coefficient Diagram Method
    Ali, Hossam
    Magdy, Gaber
    Li, Binbin
    Shabib, G.
    Elbaset, Adel A.
    Xu, Dianguo
    Mitani, Yasunori
    [J]. IEEE ACCESS, 2019, 7 : 16979 - 16990
  • [4] Impact Assessment and Mitigation of Cyber Attacks on Frequency Stability of Isolated Microgrid Using Virtual Inertia Control
    Aluko, Anuoluwapo O.
    Carpanen, R. Pillay
    Dorrell, David G.
    Ojo, Evans E.
    [J]. 2020 IEEE PES & IAS POWERAFRICA CONFERENCE, 2020,
  • [5] Twin Delayed Deep Deterministic Policy Gradient (TD3) Based Virtual Inertia Control for Inverter-Interfacing DGs in Microgrids
    Egbomwan, Osarodion Emmanuel
    Liu, Shichao
    Chaoui, Hicham
    [J]. IEEE SYSTEMS JOURNAL, 2023, 17 (02): : 2122 - 2132
  • [6] Distributed Power System Virtual Inertia Implemented by Grid-Connected Power Converters
    Fang, Jingyang
    Li, Hongchang
    Tang, Yi
    Blaabjerg, Frede
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (10) : 8488 - 8499
  • [7] Power Generation Control of Renewable Energy Based Hybrid Deregulated Power System
    Farooq, Zahid
    Rahman, Asadur
    Hussain, S. M. Suhail
    Ustun, Taha Selim
    [J]. ENERGIES, 2022, 15 (02)
  • [8] Haider R., 2018, P KIEE GEN M FALL C, P400
  • [9] The Effect of Virtual Inertia and Damping Control on the Stability Region of Load Frequency Control Systems with Time Delays
    Hasen, Suud
    Aydin, Omer
    Ayasun, Saffet
    Sonmez, Sahin
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2023, 51 (05) : 438 - 451
  • [10] Performance Assessment of an Islanded Hybrid Power System with Different Storage Combinations Using an FPA-Tuned Two-Degree-of-Freedom (2DOF) Controller
    Hussain, Israfil
    Das, Dulal Chandra
    Sinha, Nidul
    Latif, Abdul
    Hussain, S. M. Suhail
    Ustun, Taha Selim
    [J]. ENERGIES, 2020, 13 (21)