Nonstationary Stochastic Responses of Transmission Tower-Line System with Viscoelastic Material Dampers Under Seismic Excitations

被引:0
|
作者
Chang, Mingjing [1 ]
Chen, Bo [1 ]
Xiao, Xiang [2 ]
Chen, Yanzhou [3 ]
机构
[1] Wuhan Univ Technol, Sch Civil Engn & Architecture, Wuhan 430070, Peoples R China
[2] Wuhan Univ Technol, Sch Transportat & Logist Engn, Wuhan 430070, Peoples R China
[3] Cent South Architectural Design Inst Co Ltd, Wuhan 430071, Peoples R China
基金
中国国家自然科学基金;
关键词
TTL system; stochastic seismic response; VMD; control performance; nonstationary; BUILDINGS; STRATEGY;
D O I
10.3390/ma18051138
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The excessive vibration or collapse of a transmission tower-line (TTL) system under seismic excitation can result in significant losses. Viscoelastic material dampers (VMDs) have been recognized as an effective method for structural vibration mitigation. Most existing studies have focused solely on the dynamic analysis of TTL systems with control devices under deterministic seismic excitations. Studies focusing on the nonstationary stochastic control of TTL systems with VMDs have not been reported. To this end, this study proposes a comprehensive analytical framework for the nonstationary stochastic responses of TTL systems with VMDs under stochastic seismic excitations. The analytical model of the TTL system is formulated using the Lagrange equation. The six-parameter model of VMDs and the vibration control method are established. Following this, the pseudo-excitation method (PEM) is applied to compute the stochastic response of the controlled TTL system under nonstationary seismic excitations, and a probabilistic framework for analyzing extreme value responses is developed. A real TTL system in China is selected to verify the validity of the proposed method. The accuracy of the proposed framework is validated based on the Monte Carlo method (MCM). A detailed parametric investigation is conducted to determine the optimal damper installation scheme and examine the effects of the service temperature and site type on stochastic seismic responses. VMDs can effectively suppress the structural dynamic responses, with particularly stable control over displacement. The temperature and site type have a notable influence on the stochastic seismic responses of the TTL system. The research findings provide important references for improving the seismic performance of VMDs in TTL systems.
引用
收藏
页数:24
相关论文
共 50 条
  • [31] Collapse Analysis of a Transmission Tower-Line System Under Typhoon Doksuri
    Zhang, Xin
    Xie, Qiang
    COMPUTATIONAL AND EXPERIMENTAL SIMULATIONS IN ENGINEERING, ICCES 2024-VOL 2, 2025, 173 : 367 - 375
  • [32] Wind-induced response mitigation of transmission tower-line system by using magnetorheological dampers
    Hubei Key Laboratory of Roadway Bridge and Structural Engineering, Wuhan University of Technology, Wuhan 430070, China
    不详
    J Vib Shock, 2008, 3 (71-74):
  • [33] Study on the collapse failure of transmission tower-line system under downburst
    Bi W.-Z.
    Tian L.
    Gongcheng Lixue/Engineering Mechanics, 2022, 39 : 78 - 83
  • [34] Seismic responses of a long-span concrete filled steel-tube transmission tower-line system
    Xiong, Tiehua
    Liang, Shuguo
    Zou, Lianghao
    Wu, Haiyang
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2010, 43 (12): : 7 - 12
  • [35] PROGRESSIVE COLLAPSE ANALYSIS OF TRANSMISSION TOWER-LINE SYSTEM UNDER EARTHQUAKE
    Wang, W. M.
    Li, H. N.
    Tian, L.
    ADVANCED STEEL CONSTRUCTION, 2013, 9 (02): : 161 - 172
  • [36] CONTROL OF WIND-INDUCED RESPONSE OF TRANSMISSION TOWER-LINE SYSTEM BY USING MAGNETORHEOLOGICAL DAMPERS
    Chen, Bo
    Zheng, Jin
    Qu, Weilian
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2009, 9 (04) : 661 - 685
  • [37] Seismic and collapse analysis of a UHV transmission tower-line system under cross-fault ground motions
    Tian L.
    Bi W.
    Liu J.
    Dong X.
    Xin A.
    Earthquake and Structures, 2020, 19 (06): : 445 - 457
  • [38] Seismic and collapse analysis of a UHV transmission tower-line system under cross-fault ground motions
    Tian, Li
    Bi, Wenzhe
    Liu, Juncai
    Dong, Xu
    Xin, Aiqiang
    EARTHQUAKES AND STRUCTURES, 2020, 19 (06) : 445 - 457
  • [39] Seismic Reliability Analysis of Transmission Tower-line Coupling System Considering SSI Effect
    Wang L.
    Li Z.
    Wang T.
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2023, 50 (11): : 192 - 203
  • [40] Response analysis of transmission tower-line system under smart-1 seismic ground motion excitation
    Tian, L. (tianl-007@163.com), 1600, Tsinghua University (30):