Comparison of enhanced fluidity liquid chromatography with liquid chromatography for enantioseparation of selected γ-lactam derivatives

被引:1
作者
Dascalu, Anca-Elena [1 ,2 ,3 ,4 ]
Ghinet, Alina [1 ,2 ,4 ]
Billamboz, Muriel [1 ,2 ]
Speybrouck, David [5 ]
Lipka, Emmanuelle [1 ]
机构
[1] Univ Lille, Inserm, RID AGE U1167, F-59000 Lille, France
[2] JUNIA, Lab Sustainable Chem & Hlth, Hlth & Environm, F-59000 Lille, France
[3] UFR Pharm, Lab Chim Analyt, BP 83, F-59006 Lille, France
[4] Alexandru Ioan Cuza Univ, Fac Chem, Bd Carol I 11, Iasi 700506, Romania
[5] Oril Ind Servier, 13 Rue Auguste Desgenetais, F-76210 Bolbec, France
来源
JOURNAL OF CHROMATOGRAPHY OPEN | 2022年 / 2卷
关键词
Antibacterial compounds; Cellulose; Cellulose tris(3-5-dimethylphenylcarbamate); Elevated percentage of co-solvent; Flowrate; CHIRAL STATIONARY PHASES; SEPARATION STRATEGY; MOBILE PHASES; PERFORMANCE; CELLULOSE; RECOGNITION; ENANTIOMERS; AMYLOSE;
D O I
10.1016/j.jcoa.2021.100026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present paper describes the study of eight racemic gamma-lactam derivatives with the goal of comparing three modes of liquid chromatography which are the reversed-phase mode, the normal-phase mode and the polar organic solvent chromatography mode with super/subcritical fluid chromatography and enhanced fluidity liquid chromatography in extreme conditions i.e. when the CO2 percentage is practically zero. For this study two CPSs were chosen. Chiralcel OD-H was used in HPLC conditions and Chiralcel OD-H and Lux Cellulose-2 were used in SFC conditions. It is reported in this work that the introduction of chlorine substituent on polysaccharide-based selectors contributes to an improved enantioselectivity in supercritical fluid chromatography (SFC) compared to the electron-donating substituted phenyl carbamate column, allowing the complete separation of seven analytes out of the eight. The effect of enhanced fluidity liquid chromatography conditions, described as an intermediate mode between HPLC and SFC is also explored. In this case, the composition of the mobile phase starting at 80% CO2 was replaced with almost 100% ethanol at the end, this assay achieving further extension of the polarity range of the mobile phase in a single run and successfully enabling the simultaneous analysis and separation of the racemates. Under a mobile phase constituted of 99% ethanol, the resolution values of the gamma-lactam derivatives on Lux Cellulose-2 CSP, were comprised between 1.91 and 3.44. High values of flowrates, ranging from 4 mL/min to 10 mL/min were also evaluated for some analytes on the highly retentive Lux Cellulose-2 CSP, leading to resolution equal to 6.24 for compound 6 and 4.64 for compound 8.
引用
收藏
页数:10
相关论文
共 40 条
[11]   Applicability of supercritical fluid chromatography - mass spectrometry to metabolomics. I - Optimization of separation conditions for the simultaneous analysis of hydrophilic and lipophilic substances [J].
Desfontaine, Vincent ;
Losacco, Gioacchino Luca ;
Gagnebin, Yoric ;
Pezzatti, Julian ;
Farrell, William P. ;
Gonzalez-Ruiz, Victor ;
Rudaz, Serge ;
Veuthey, Jean-Luc ;
Guillarme, Davy .
JOURNAL OF CHROMATOGRAPHY A, 2018, 1562 :96-107
[12]  
Hesse G., 1973, CHROMATOGRAPHIA, V6, P277, DOI DOI 10.1007/BF02282825
[13]   Supercritical fluid chromatography versus high performance liquid chromatography for enantiomeric and diastereoisomeric separations on coated polysaccharides-based stationary phases: Application to dihydropyridone derivatives [J].
Hoguet, Vanessa ;
Charton, Julie ;
Hecquet, Paul-Emile ;
Lakhmi, Chahinaze ;
Lipka, Emmanuelle .
JOURNAL OF CHROMATOGRAPHY A, 2018, 1549 :39-50
[14]   UNIFIED FLUID CHROMATOGRAPHY [J].
ISHII, D ;
TAKEUCHI, T .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1989, 27 (02) :71-74
[15]   Comparison of liquid and supercritical fluid chromatography mobile phases for enantioselective separations on polysaccharide stationary phases [J].
Khater, Syame ;
Lozac'h, Marie-Anne ;
Adam, Isabelle ;
Francotte, Eric ;
West, Caroline .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1467 :463-472
[16]   Insights into chiral recognition mechanism in supercritical fluid chromatography IV. Chlorinated polysaccharide stationary phases [J].
Khater, Syame ;
Zhang, Yingru ;
West, Caroline .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1363 :294-310
[17]   Supercritical fluid chromatography and liquid chromatography for isomeric separation of a multiple chiral centers analyte [J].
La, Zuo ;
Charton, Julie ;
Etienne, Lucile ;
Bourey, Julie ;
Lipka, Emmanuelle .
JOURNAL OF CHROMATOGRAPHY A, 2021, 1651
[18]   Preparative Scale Resolution of Enantiomers Enables Accelerated Drug Discovery and Development [J].
Leek, Hanna ;
Andersson, Shalini .
MOLECULES, 2017, 22 (01)
[19]   The many faces of packed column supercritical fluid chromatography - A critical review [J].
Lesellier, Eric ;
West, Caroline .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1382 :2-46
[20]   Separation of enantiomers of native amino acids with polysaccharide-based chiral columns in supercritical fluid chromatography [J].
Lipka, Emmanuelle ;
Dascalu, Anca-Elena ;
Messara, Yasmine ;
Tsutsqiridze, Eka ;
Farkas, Tivadar ;
Chankvetadze, Bezhan .
JOURNAL OF CHROMATOGRAPHY A, 2019, 1585 :207-212