Fault identification of hydropower unit based on time-frequency feature map of vibration signals and Convrbm-ResNet

被引:0
作者
Chen, Tingxi [1 ]
Chen, Jinbao [2 ]
Zou, Yidong [1 ]
Liu, Dong [2 ,3 ]
Hu, Wenqing [1 ]
Zheng, Yang [1 ]
Xiao, Zhihuai [1 ]
机构
[1] Wuhan Univ, Sch Power & Mech Engn, Wuhan 430072, Peoples R China
[2] China Yangtze River Elect Power Co Ltd, Wuhan 430000, Hubei, Peoples R China
[3] Xihua Univ, Key Lab Fluid & Power Machinery, Minist Educ, Chengdu 610039, Peoples R China
基金
中国国家自然科学基金;
关键词
time-frequency feature map; convolutional restricted Boltzmann machine; residual network; fault diagnosis; hydropower unit vibration signal; EMPIRICAL MODE DECOMPOSITION; DIAGNOSIS; SUPPORT;
D O I
10.1088/1361-6501/ad8811
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
To address the significant impact of the non-stationarity and nonlinearity of vibration signals on the accuracy of fault identification in hydropower units, a method for condition identification based on time-frequency characteristics of vibration signals and Convolutional Restricted Boltzmann Machines-Residual Network (ConvRBM-ResNet ) is proposed. The vibration signals are first decomposed by adopting Complementary Comprehensive Empirical Modal Decomposition to further obtain Intrinsic Mode Functions (IMFs) at various frequencies. Then, by combining correlation analysis, the more sensitive IMF components are extracted. Furthermore, the obtained effective IMF components are converted into time-frequency feature maps, which are consequently adopted as inputs to pre-train the ConvRBM model to simplify feature representation. Finally, using the fault category as the output, a fault identification model for hydropower units is obtained by training ConvRBM-ResNet. The proposed fault identification model is validated with actual operation data of a hydropower station. The results indicate that the proposed fault identification model can accurately identify the operating status of the hydropower unit, achieving an accuracy of 98.88%, which is a 4% improvement over the non-improved method. The time cost is reasonable, and the model demonstrates strong robustness.
引用
收藏
页数:17
相关论文
共 38 条
[1]   Application of Time-Frequency Analysis in Rotating Machinery Fault Diagnosis [J].
Bai, Yihao ;
Cheng, Weidong ;
Wen, Weigang ;
Liu, Yang .
SHOCK AND VIBRATION, 2023, 2023
[2]  
Balduzzi D., 2017, PMLR
[3]  
Bao Z., 2021, DAT SCI 7 INT C PI 1, Vvol 7
[4]   Discussion on the development direction of hydropower in China [J].
Bin, Duan .
CLEAN ENERGY, 2021, 5 (01) :10-18
[5]   Design of a progressive fault diagnosis system for hydropower units considering unknown faults [J].
Chen, Jinbao ;
Zheng, Yang ;
Deng, Xiaoqin ;
Wang, Yunhe ;
Hu, Wenqing ;
Xiao, Zhihuai .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (01)
[6]  
Cho K, 2013, IEEE IJCNN
[7]   A novel denoising method of the hydro-turbine runner for fault signal based on WT-EEMD [J].
Dao, Fang ;
Zeng, Yun ;
Qian, Jing .
MEASUREMENT, 2023, 219
[8]   Acoustic Vibration Approach for Detecting Faults in Hydroelectric Units: A Review [J].
Dao, Fang ;
Zeng, Yun ;
Zou, Yidong ;
Li, Xiang ;
Qian, Jing .
ENERGIES, 2021, 14 (23)
[9]   Recent advances in time-frequency analysis methods for machinery fault diagnosis: A review with application examples [J].
Feng, Zhipeng ;
Liang, Ming ;
Chu, Fulei .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2013, 38 (01) :165-205
[10]   Training restricted Boltzmann machines: An introduction [J].
Fischer, Asja ;
Igel, Christian .
PATTERN RECOGNITION, 2014, 47 (01) :25-39