Gray-Box Modeling and Key Parameters Monitoring of Single-Phase PWM Rectifiers Based on Digital Twins

被引:0
作者
Zhang, Sihui [1 ]
Song, Wensheng [1 ]
Zhang, Zhiwei [1 ]
Chen, Jian [1 ]
Ye, Cunxin [1 ]
Ma, Chenwei [1 ]
Huang, Jin [2 ]
机构
[1] Southwest Jiaotong Univ, Sch Elect Engn, Chengdu 611756, Peoples R China
[2] China Acad Railway Sci, Beijing 100081, Peoples R China
基金
中国国家自然科学基金;
关键词
Monitoring; Rectifiers; Pulse width modulation; Mathematical models; Accuracy; Integrated circuit modeling; Capacitors; Digital twins; Glass box; Optimization; Control parameters; digital twin (DT); gray-box model; health monitoring; single-phase pulsewidth modulation (PWM) rectifier; ALGORITHM;
D O I
10.1109/JESTPE.2024.3482856
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Considering that control parameters are difficult to obtain due to industry confidentiality and intellectual property limitations, the existing white-box digital twin (DT) models of single-phase pulsewidth modulation (PWM) rectifiers are difficult to apply in practical applications. Therefore, this article develops a gray-box DT model that can overcome the limitations of unknown control parameters and has higher accuracy. First, the dead-time effect and the equivalent series resistance (ESR) of capacitors are considered in the DT model to improve model accuracy. The operational characteristics of the DT model are closer to the actual system and have more comprehensive health monitoring capability. Then, based on the collected data from actual physical systems under dynamic and static operating conditions, the developed DT model is implemented on an independent server. The key parameters of the model are accurately monitored by using a hybrid algorithm of particle swarm and whale optimization. Finally, the proposed model and its parameter monitoring capability have been validated under different operating conditions, parameters, and control schemes, and the error impact has also been analyzed. This study contributes to the application of noninvasive health monitoring in practical power converters.
引用
收藏
页码:589 / 603
页数:15
相关论文
共 39 条
[1]  
Aamir Muhammad, 2011, 8th International Conference on Power Electronics - ECCE Asia, P2282
[2]   A Gray-Box Method for Stability and Controller Parameter Estimation in HVDC-Connected Wind Farms Based on Nonparametric Impedance [J].
Amin, Mohammad ;
Molinas, Marta .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (03) :1872-1882
[3]   Uninterruptible Power Supply Employing SinglePhase Matrix Converter Topology [J].
Baharom, Rahimi ;
Rawi, Muhammad Shawwal Mohamad ;
Abd Rahman, Nor Farahaida .
2020 IEEE INTERNATIONAL CONFERENCE ON POWER AND ENERGY (PECON 2020), 2020, :19-23
[4]  
Bansal S., 2023, DECIS ANAL J, V9, DOI 10.1016/j.dajour.2023.100361
[5]  
Bhattacharya Soham, 2023, 2023 IEEE International Conference on Electrical, Automation and Computer Engineering (ICEACE), P260, DOI 10.1109/ICEACE60673.2023.10442673
[6]  
Blahnik V, 2014, PROCEEDINGS OF THE 2014 16TH INTERNATIONAL CONFERENCE ON MECHATRONICS (MECHATRONIKA 2014), P652, DOI 10.1109/MECHATRONIKA.2014.7018337
[7]   Self-Evolving Digital Twin-Based Online Health Monitoring of Multiphase Boost Converters [J].
Choksi, Kushan ;
Mirza, Abdul Basit ;
Zhou, Austin ;
Singh, Deepi ;
Hijikata, Masayuki ;
Luo, Fang .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (12) :16100-16117
[8]   Standard Steady State Genetic Algorithms Can Hillclimb Faster Than Mutation-Only Evolutionary Algorithms [J].
Corus, Dogan ;
Oliveto, Pietro S. .
IEEE TRANSACTIONS ON EVOLUTIONARY COMPUTATION, 2018, 22 (05) :720-732
[9]   Capacitor ESR and C Monitoring in Modular Multilevel Converters [J].
Deng, Fujin ;
Heng, Qian ;
Liu, Chengkai ;
Cai, Xu ;
Zhu, Rongwu ;
Chen, Zhe ;
Chen, Wu .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (04) :4063-4075
[10]  
[邓知先 Deng Zhixian], 2016, [中国电机工程学报, Proceedings of the Chinese Society of Electrical Engineering], V36, P2996