Early vascular healing after neXt-generation drug-eluting stent implantation in Patients with non-ST elevation acute Coronary syndrome: a randomized optical coherence Tomography imaging study (EXPECT)

被引:0
作者
Ma, Wen-Rui [1 ,2 ]
Li, Qian [1 ,2 ]
Wang, Qin [3 ]
Cheng, You-Wei [1 ,2 ]
Nai, Chang-Sheng [1 ,2 ]
Wang, Xin-Yu [1 ,2 ]
Li, Zheng [1 ,2 ]
Wang, Yang [4 ]
Iqbal, Javaid [5 ]
Bourantas, Christos V. [6 ]
Zhang, Yao-Jun [1 ,3 ]
机构
[1] Xuzhou New Hlth Geriatr Hosp, Dept Cardiol, 281 North Zhongshan Rd, Xuzhou 221005, Jiangsu, Peoples R China
[2] Xuzhou Canc Hosp, Dept Cardiol, Xuzhou, Jiangsu, Peoples R China
[3] Xuzhou Med Univ, Dept Cardiol, 281 North Zhongshan Rd, Xuzhou 221005, Jiangsu, Peoples R China
[4] Chinese Acad Med Sci & Peking Union Med Coll, Fuwai Hosp, Natl Ctr Cardiovasc Dis, Beijing, Peoples R China
[5] Sheffield Teaching Hosp NHS Fdn Trust, Dept Cardiol, Sheffield, England
[6] Barts Heart Ctr Barts Hlth NHS Trust, Dept Cardiol, London, England
关键词
Acute coronary syndrome; Drug-eluting stent; Early strut coverage; Optical coherence tomography; Percutaneous coronary intervention; EARLY STRUT COVERAGE; NEOINTIMAL COVERAGE; FOLLOW-UP; MALAPPOSITION; ANGIOGRAPHY; APPOSITION; POLYMER; THROMBOSIS; DISTANCE;
D O I
10.1007/s10554-024-03258-w
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Early vascular healing after drug-eluting stent (DES) implantation is associated with better outcomes and lower incidence of in-stent thrombosis. To examine vascular healing response in patients with non-ST elevation acute coronary syndrome (NSTE-ACS) undergoing percutaneous coronary intervention (PCI) guided by optical coherence tomography (OCT) versus angiography alone. Sixty patients were randomized 1:1:1 to OCT-guided PCI with 3-month OCT follow-up (O3 group, n = 20), angiography-guided PCI with 3-month OCT follow-up (A3 group, n = 20), or angiography-guided PCI with 6-month OCT follow-up (A6 group, n = 20). The primary endpoint was the proportion of covered struts at 3- or 6-month follow-up. The proportion of covered struts in the O3 group was significantly higher than in the A3 group (95.2% vs. 92.3%, p < 0.001), but lower than in the A6 group (95.2% vs. 97.4%, p < 0.001). The O3 group had a lower proportion of incomplete strut apposition (ISA) than the A3 group (0.46% vs. 0.76%, p = 0.006), and higher than the A6 group (0.46% vs. 0.27%, p = 0.018) at follow-up. The optimal cut-off value of ISA after implantation of DES for predicting stent coverage at 3 and 6-month follow-up was 200 mu m and 308 mu m, respectively. Only one patient experienced target lesion revascularization in the A3 group during a 3-year clinical follow-up. In patients with NSTE-ACS undergoing PCI with DES, OCT guidance achieved higher strut coverage compared with angiography guidance at 3-month follow-up. However, the difference in the strut coverage between the OCT-guided group and the angiography-guided group at 6 months indicates that the degree of endothelialization may be more time-dependent instead of invasive device guidance.
引用
收藏
页数:9
相关论文
共 30 条
[1]   Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial [J].
Ali, Ziad A. ;
Maehara, Akiko ;
Genereux, Philippe ;
Shlofmitz, Richard A. ;
Fabbiocchi, Franco ;
Nazif, Tamim M. ;
Guagliumi, Giulio ;
Meraj, Perwaiz M. ;
Alfonso, Fernando ;
Samady, Habib ;
Akasaka, Takashi ;
Carlson, Eric B. ;
Leesar, Massoud A. ;
Matsumura, Mitsuaki ;
Ozan, Melek Ozgu ;
Mintz, Gary S. ;
Ben-Yehuda, Ori ;
Stone, Gregg W. .
LANCET, 2016, 388 (10060) :2618-2628
[2]   Optical Coherence Tomography Guided Percutaneous Coronary Intervention With Nobori Stent Implantation in Patients With Non-ST-Segment-Elevation Myocardial Infarction (OCTACS) Trial Difference in Strut Coverage and Dynamic Malapposition Patterns at 6 Months [J].
Antonsen, Lisbeth ;
Thayssen, Per ;
Maehara, Akiko ;
Hansen, Henrik Steen ;
Junker, Anders ;
Veien, Karsten Tange ;
Hansen, Knud Norregaard ;
Hougaard, Mikkel ;
Mintz, Gary S. ;
Jensen, Lisette Okkels .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (08)
[3]   Serial Assessment of Strut Coverage of Biodegradable Polymer Drug-Eluting Stent at 1, 2, and 3 Months After Stent Implantation by Optical Frequency Domain Imaging The DISCOVERY 1TO3 Study (Evaluation With OFDI of Strut Coverage of Terumo New Drug Eluting Stent With Biodegradable Polymer at 1, 2, and 3 Months) [J].
Chevalier, Bernard ;
Smits, Pieter C. ;
Carrie, Didier ;
Mehilli, Julinda ;
Van Boven, Ad J. ;
Regar, Evelyn ;
Sawaya, Fadi J. ;
Chamie, Daniel ;
Kraaijeveld, Adriaan O. ;
Hovasse, Thomas ;
Vlachojannis, Georgios J. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (12)
[4]   Neointimal coverage and stent strut apposition six months after implantation of a paclitaxel eluting stent in acute coronary syndromes: An optical coherence tomography study [J].
Davlouros, Periklis A. ;
Nikokiris, George ;
Karantalis, Vasileios ;
Mavronasiou, Eleni ;
Xanthopoulou, Ioanna ;
Damelou, Anastasia ;
Tsigkas, Grigorios ;
Alexopoulos, Dimitrios .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 151 (02) :155-159
[5]   Early Healing Assessment with Optical Coherence Tomography of Everolimus-Eluting Stents with Bioabsorbable Polymer (Synergy™) at 3 and 6 Months After Implantation [J].
de la Torre Hernandez, Jose M. ;
Tejedor, Paula ;
Garcia Camarero, Tamara ;
Duran, Juan M. ;
Lee, Dae-Hyun ;
Monedero, Jairo ;
Sainz Laso, Fermin ;
Alvarez Calderon, Marcos ;
Veiga, Gabriela ;
Zueco, Javier .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 88 (03) :E67-E73
[6]   Pathological correlates of late drug-eluting stent thrombosis - Strut coverage as a marker of endothelialization [J].
Finn, Aloke V. ;
Joner, Michael ;
Nakazawa, Gaku ;
Kolodgie, Frank ;
Newell, John ;
John, Mike C. ;
Gold, Herman K. ;
Virmani, Renu .
CIRCULATION, 2007, 115 (18) :2435-2441
[7]   Incomplete Stent Apposition Causes High Shear Flow Disturbances and Delay in Neointimal Coverage as a Function of Strut to Wall Detachment Distance Implications for the Management of Incomplete Stent Apposition [J].
Foin, Nicolas ;
Gutierrez-Chico, Juan Luis ;
Nakatani, Shimpei ;
Torii, Ryo ;
Bourantas, Christos V. ;
Sen, Sayan ;
Nijjer, Sukhjinder ;
Petraco, Ricardo ;
Kousera, Chrysa ;
Ghione, Matteo ;
Onuma, Yoshinobu ;
Garcia-Garcia, Hector M. ;
Francis, Darrel P. ;
Wong, Philip ;
Di Mario, Carlo ;
Davies, Justin E. ;
Serruys, Patrick W. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (02) :180-189
[8]   A new optical coherence tomography-based calcium scoring system to predict stent underexpansion [J].
Fujino, Akiko ;
Mintz, Gary S. ;
Matsumura, Mitsuaki ;
Lee, Tetsumin ;
Kim, Song-Yi ;
Hoshino, Masahiro ;
Usui, Eisuke ;
Yonetsu, Taishi ;
Haag, Elizabeth S. ;
Shlofmitz, Richard A. ;
Kakuta, Tsunekazu ;
Maehara, Akiko .
EUROINTERVENTION, 2018, 13 (18) :E2182-E2189
[9]   Vascular Tissue Reaction to Acute Malapposition in Human Coronary Arteries Sequential Assessment With Optical Coherence Tomography [J].
Gutierrez-Chico, Juan Luis ;
Wykrzykowska, Joanna ;
Nueesch, Eveline ;
van Geuns, Robert Jan ;
Koch, Karel T. ;
Koolen, Jacques J. ;
di Mario, Carlo ;
Windecker, Stephan ;
van Es, Gerrit-Anne ;
Gobbens, Pierre ;
Jueni, Peter ;
Regar, Evelyn ;
Serruys, Patrick W. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (01) :20-U81
[10]   Delayed Coverage in Malapposed and Side-Branch Struts With Respect to Well-Apposed Struts in Drug-Eluting Stents In Vivo Assessment With Optical Coherence Tomography [J].
Gutierrez-Chico, Juan Luis ;
Regar, Evelyn ;
Nueesch, Eveline ;
Okamura, Takayuki ;
Wykrzykowska, Joanna ;
di Mario, Carlo ;
Windecker, Stephan ;
van Es, Gerrit-Anne ;
Gobbens, Pierre ;
Jueni, Peter ;
Serruys, Patrick W. .
CIRCULATION, 2011, 124 (05) :612-U192