A preliminary study of linear accelerator-based spatially fractionated radiotherapy

被引:0
作者
Lee, Young Kyu [1 ]
Seol, Yunji [1 ]
Kim, Byeong Jin [1 ]
Choi, Kyu Hye [1 ]
Hong, Ji Hyun [1 ]
Park, Chan-beom [2 ]
Kim, Sun Hwa [2 ]
Park, Hyeong Wook [3 ]
Cheon, Wonjoong [1 ]
Kang, Young Nam [1 ]
Choi, Byung-Ock [1 ]
机构
[1] Catholic Univ Korea, Seoul St Marys Hosp, Coll Med, Dept Radiat Oncol, Seoul, South Korea
[2] Catholic Univ Korea, Coll Med, Dept Biomed & Hlth Sci, Seoul, South Korea
[3] Kyonggi Univ, Dept Med Phys, Suwon, South Korea
来源
FRONTIERS IN ONCOLOGY | 2025年 / 14卷
关键词
spatially fractionated radiation therapy (SFRT); lattice radiation therapy (LRT); multi-leaf collimator (MLC); peak-to-valley dose ratio (PVDR); monitor unit (MU) analysis; RADIATION-THERAPY; LUNG-CANCER;
D O I
10.3389/fonc.2024.1495216
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose This study aimed to provide quantitative information for implementing Lattice radiotherapy (LRT) using a medical linear accelerator equipped with the Millennium 120 multi-leaf collimator (MLC). The research systematically evaluated the impact of varying vertex diameters and separations on dose distribution, peak-to-valley dose ratio (PVDR), and normal tissue dose.Methods A cylindrical Virtual Water (TM) phantom was used to create LRT treatments using the Eclipse version 16.0 treatment planning system (Varian, Palo Alto, USA). The plans were optimized employing a 3 x 3 x 3 lattice structure with vertex diameters ranging from 0.5 to 2.0 cm and separations from 1.0 to 5.0 cm. The prescribed dose was 20.0 Gy to 50% of the vertex volume in a single fraction. Peak-to-valley dose ratio (PVDR) was calculated along three orthogonal axes, and normal tissue dose and monitor units (MU) were analyzed. Additionally, the modulation complexity score (MCS) was calculated for each plan to quantitatively assess treatment plan complexity.Results The PVDR analysis demonstrated heterogeneous dose distribution, with optimal values below 30% in all directions for 5.0 cm separation. PVDR in the superior-inferior direction was consistently lower than in other directions. Normal tissue dose analysis revealed increasing mean dose with larger diameters and separations, while the volume receiving high doses decreased. MU analysis showed significant contributions from collimator angles of 315.0 degrees and 45.0 degrees. MCS values ranged from 0.02 to 0.17 for 0.5 cm vertex diameter and 0.08 to 0.20 for larger diameters (1.0-2.0 cm) across different separations, respectively.Conclusions This study demonstrates the technical feasibility of implementing LRT using a medical linear accelerator with Millennium 120 MLC. The findings provide insights into optimizing LRT treatment plans, offering a comprehensive quantitative reference for achieving desired dose heterogeneity while maintaining normal tissue protection.
引用
收藏
页数:11
相关论文
共 24 条
  • [1] Dosimetric quantities and cell survival for spatially fractionated radiation therapy
    Ahmed, Mabroor
    Bicher, Sandra
    Stewart, Robert D.
    Bartzsch, Stefan
    Schmid, Thomas E.
    Combs, Stephanie E.
    Meyer, Juergen
    [J]. FRONTIERS IN PHYSICS, 2023, 10
  • [2] Amendola B., 2010, Cureus, V2, DOI [DOI 10.1667/RR2780.1, 10.7759/cureus.15, DOI 10.7759/CUREUS.15]
  • [3] Safety and Efficacy of Lattice Radiotherapy in Voluminous Non-small Cell Lung Cancer
    Amendola, Beatriz E.
    Perez, Naipy C.
    Wu, Xiaodong
    Amendola, Marco A.
    Qureshi, Ian Z.
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (03)
  • [4] Improved outcome of treating locally advanced lung cancer with the use of Lattice Radiotherapy (LRT): A case report
    Amendola, Beatriz E.
    Perez, Naipy C.
    Wu, Xiaodong
    Suarez, Jesus Manuel Blanco
    Lu, Jiade J.
    Amendola, Marco
    [J]. CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2018, 9 : 68 - 71
  • [5] High dose bystander effects in spatially fractionated radiation therapy
    Asur, Rajalakshmi
    Butterworth, Karl T.
    Penagaricano, Jose A.
    Prise, Kevin M.
    Griffin, Robert J.
    [J]. CANCER LETTERS, 2015, 356 (01) : 52 - 57
  • [6] A Current Review of Spatial Fractionation: Back to the Future?
    Billena, Cole
    Khan, Atif J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 104 (01): : 177 - 187
  • [7] The Use of Lattice Radiation Therapy (LRT) in the Treatment of Bulky Tumors: A Case Report of a Large Metastatic Mixed Mullerian Ovarian Tumor
    Blanco Suarez, Jesus Manuel
    Amendola, Beatriz E.
    Perez, Naipy
    Amendola, Marco
    Wu, Xiaodong
    [J]. CUREUS, 2015, 7 (11):
  • [8] Tumor volume: a basic and specific response predictor in radiotherapy
    Dubben, HH
    Thames, HD
    Beck-Bornholdt, HP
    [J]. RADIOTHERAPY AND ONCOLOGY, 1998, 47 (02) : 167 - 174
  • [9] Spatially fractionated stereotactic body radiation therapy (Lattice) for large tumors
    Duriseti, Sai
    Kavanaugh, James
    Goddu, Sreekrishna
    Price, Alex
    Knutson, Nels
    Reynoso, Francisco
    Michalski, Jeff
    Mutic, Sasa
    Robinson, Clifford
    Spraker, Matthew B.
    [J]. ADVANCES IN RADIATION ONCOLOGY, 2021, 6 (03)
  • [10] Dosimetric Performance Evaluation of MLC-based and Cone-based 3D Spatially Fractionated LATTICE Radiotherapy
    Ertan, Ferihan
    Yeginer, Mete
    Zorlu, Faruk
    [J]. RADIATION RESEARCH, 2023, 199 (02) : 161 - 169