Evaluation Tibia Rotation in Total Knee Arthroplasty Designed for Deep Knee Flexion Using Knee Kinematics Motion Simulator

被引:0
作者
Triwardono, Joko [1 ]
Kartika, Ika [1 ]
Sutowo, Cahya [1 ]
Ciptasari, Nurhayati Indah [1 ]
Elvira, Bunga Rani [1 ]
Rokhmanto, Fendy [1 ]
Asmaria, Talitha [2 ]
Purnama, Harry [3 ]
Rahyussalim [4 ]
机构
[1] KST BJ Habibie, Natl Res & Innovat Agcy, Res Ctr Met, South Tangerang 15314, Indonesia
[2] KST Soekarno, Natl Res & Innovat Agcy, Res Ctr Biomed, Bogor 16911, Indonesia
[3] KST BJ Habibie, Natl Res & Innovat Agcy, Res Ctr Proc & Mfg Ind Technol, South Tangerang 15314, Indonesia
[4] Univ Indonesia, RS Ciptomangunkusumo, Orthopaed & Traumatol Dept, Jakarta 10430, Indonesia
关键词
total knee arthroplasty; tibia rotation; knee kinematics; post-operative pain; polyethylene wear; aseptic loosening; instability; CONTACT AREA; THICKNESS; OUTCOMES; BEARING;
D O I
10.4028/p-SrL1Hn
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Total knee arthroplasty is a successful procedure for treating chronic degenerative knee pathologies, many patients are dissatisfied with the results of the standard design. Improper tibia rotation of the implant is suspected to contribute to post-operative pain, polyethylene wears, aseptic loosening, and instability. Many factors can influence the alteration of knee kinematics after surgery including differences in implant design. Using magnetic resonance imaging, tibia rotation in a normal knee has-15.0 degrees and-2.5 degrees in weight-bearing males neutral tibia rotation, and tibia rotation in postoperative patients has 2.1 degrees and 9.5 degrees using computer tomography. In this study, a knee joint implant was developed to facilitate a high range of motion. Tibia rotation was observed with the axes of knee motion joint implants varied from 0 degrees, 2 degrees, 3 degrees to 5 degrees and knee bend measurements at 30 degrees, 60 degrees, 90 degrees, 120 degrees, and 150 degrees of knee flexion using the knee kinematic motion simulator and the results will be compared with the results from magnetic resonance imaging and computer tomography. Using statistical analysis resulted for 0 degrees and 2 degrees kinematics alignment, the p-value of the development product is 0.072 and 0.054 (p > 0.05), for 3 degrees and 5 degrees kinematics alignment, the p-value of the development product is 0.039 and 0.031 (p < 0.05). Thus, the kinematics development product at 0 degrees and 2 degrees kinematics alignment are similar to a normal human knee joint. Evaluation of knee kinematics implant using a knee motion simulatoris expected to become astandard procedure before performing total knee arthroplasty surgery. This similarity in kinematics knee implant with a normal knee is to be expected to reduce postoperative pain, polyethylene wears, aseptic loosening, and instability during deep knee flexion and minimize the risk of implant failure.
引用
收藏
页码:95 / 107
页数:13
相关论文
共 40 条
  • [31] Polyethylene wear and metal release of TiNbN-coated knee implants
    Schroeder, Stefan
    Braun, Steffen
    Mueller, Ulrike
    Schroeder, Mark
    Sonntag, Robert
    Jaeger, Sebastian
    Kretzer, Jan Philippe
    [J]. WEAR, 2020, 458
  • [32] The flexion gap in normal knees - An MRI study
    Tokuhara, Y
    Kadoya, Y
    Nakagawa, S
    Kobayashi, A
    Takaoka, K
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (08): : 1133 - 1136
  • [33] Evaluation of the Malalignment Varus- Valgus in Total Knee Arthroplasty Designed for Deep Knee Flexion Used Knee Kinematic Motion Simulator
    Triwardono, Joko
    Rokhmanto, Fendy
    Roberto, Rahadian
    Kartika, Ika
    Saragih, Agung Shamsuddin
    Whulanza, Yudan
    Shuib, Solehuddin
    Supriadi, Sugeng
    [J]. JOURNAL OF BIOMIMETICS BIOMATERIALS AND BIOMEDICAL ENGINEERING, 2023, 59 : 119 - 130
  • [34] Finite Element Analysis Contact Stresses on Tibiofemoral Joint and Post Polyethylene Components Used to Evaluated Predesign Knee Implant
    Triwardono, Joko
    Saragih, Agung Shamsuddin
    Abrar, Fuad
    Utomo, M. Satrio
    Kartika, Ika
    Whulanza, Yudan
    Supriadi, Sugeng
    [J]. JOURNAL OF BIOMIMETICS BIOMATERIALS AND BIOMEDICAL ENGINEERING, 2022, 55 : 46 - 55
  • [35] Evaluation of the Contact Area in Total Knee Arthroplasty Designed for Deep Knee Flexion
    Triwardono, Joko
    Supriadi, Sugeng
    Whulanza, Yudan
    Saragih, Agung Shamsuddin
    Novalianita, Deva Ariana
    Utomo, Muhammad Satrio
    Kartika, Ika
    [J]. INTERNATIONAL JOURNAL OF TECHNOLOGY, 2021, 12 (06) : 1312 - 1322
  • [36] Difference in implant design affects midflexion rotational laxity in cruciate-retaining total knee arthroplasty: a computer navigation study
    Tsuda, Takashi
    Hino, Kazunori
    Kutsuna, Tatsuhiko
    Watamori, Kunihiko
    Kinoshita, Tomofumi
    Takao, Masaki
    [J]. JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2023, 10 (01)
  • [37] Tzanetis P., 2021, MDPI
  • [38] Early aseptic loosening of the tibial component at the cement-implant interface in total knee arthroplasty: a narrative overview of potentially associated factors
    Van Otten, Teun J. M.
    Van Loon, Corne J. M.
    [J]. ACTA ORTHOPAEDICA BELGICA, 2022, 88 (01): : 103 - 111
  • [39] The Definition of the Tibial Sagittal Plane and the Paradox of Imageless Navigation and Robotics: A Cadaveric Study
    Vermue, Hannes
    Stroobant, Lenka
    Pringels, Lauren
    Chevalier, Amelie
    Victor, Jan
    [J]. JOURNAL OF ARTHROPLASTY, 2023, 38 (06) : S374 - S378
  • [40] Ahlback grading of osteloarthritis of the knee -: Poor reproducibility and validity based on visual inspection of the joint
    Weidow, Jonas
    Cederlund, Claes-Goran
    Ranstam, Jonas
    Karrholm, Johan
    [J]. ACTA ORTHOPAEDICA, 2006, 77 (02) : 262 - 266