Evaluation of the Accuracy of 3D Printed Patient-Specific Brain Biopsy Guide Using 3D Volume Rendering Technique in Canine Cadavers

被引:0
作者
Jeong, Minseung [1 ]
Ko, Jongchan [1 ]
Yu, Yong [1 ]
Heo, Suyoung [1 ]
机构
[1] Jeonbuk Natl Univ, Coll Vet Med, Iksan 54596, South Korea
来源
ANIMALS | 2024年 / 14卷 / 21期
基金
新加坡国家研究基金会;
关键词
brain biopsy; 3D printed guides; 3D volume rendering; needle placement accuracy; STEREOTACTIC BIOPSY; CT; SYSTEM; DOGS; NEOPLASIA; DEVICE; SAFETY; TUMORS; RISK; MRI;
D O I
10.3390/ani14213163
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
The objective of this study was to evaluate the accuracy of a CT-based, 3D-printed, patient-specific brain biopsy guide (3D-psBBG) through the application of a transfrontal approach in canine cadavers. A total of ten canine cadavers, with weights ranging from 4.36 to 14.4 kg, were subjected to preoperative CT scans to generate 3D skull models. Customized biopsy guides were created based on these models and manufactured using 3D printing technology. Twenty spinal needle insertions were performed, and the accuracy of needle placement was evaluated through both CT and 3D volume-rendering techniques. The mean needle placement error was 2.1 mm, with no significant differences observed between insertions targeting the fronto-olfactory and piriform lobes. The 3D volume-rendering method demonstrated superior accuracy compared to the CT method, with statistically significant differences in placement errors for both targets. The average time required for the design and manufacture of the guides was 249 min. These findings indicate the high accuracy and potential clinical application of CT-based 3D-psBBG for improving diagnostic outcomes in veterinary neurology.
引用
收藏
页数:16
相关论文
共 37 条
  • [1] Brainard JA, 1997, ARCH PATHOL LAB MED, V121, P481
  • [2] COMPARATIVE MAGNETIC RESONANCE IMAGING FINDINGS BETWEEN GLIOMAS AND PRESUMED CEREBROVASCULAR ACCIDENTS IN DOGS
    Cervera, Vicente
    Mai, Wilfried
    Vite, Charles H.
    Johnson, Victoria
    Dayrell-Hart, Betsy
    Seiler, Gabriela S.
    [J]. VETERINARY RADIOLOGY & ULTRASOUND, 2011, 52 (01) : 33 - 40
  • [3] DESCRIPTION AND VALIDATION OF A MAGNETIC RESONANCE IMAGING-GUIDED STEREOTACTIC BRAIN BIOPSY DEVICE IN THE DOG
    Chen, Annie V.
    Wininger, Fred A.
    Frey, Stephen
    Comeau, Roch M.
    Bagley, Rodney S.
    Tucker, Russell L.
    Schneider, Adam R.
    Gay, John M.
    [J]. VETERINARY RADIOLOGY & ULTRASOUND, 2012, 53 (02) : 150 - 156
  • [4] Accuracy of Patient-Specific 3D Printed Drill Guides in the Placement of a Canine Coxofemoral Toggle Pin through a Minimally Invasive Approach
    Darrow, Brett G.
    Snowdon, Kyle A.
    Hespel, Adrien
    [J]. VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2021, 34 (01) : 1 - 8
  • [5] Glioma Mimics: Magnetic Resonance Imaging Characteristics of Granulomas in Dogs
    Diangelo, Lauren
    Cohen-Gadol, Aaron
    Heng, Hock Gan
    Miller, Margaret A.
    Hague, Devon W.
    Rossmeisl, John H.
    Bentley, R. Timothy
    [J]. FRONTIERS IN VETERINARY SCIENCE, 2019, 6
  • [6] DORN CR, 1968, JNCI-J NATL CANCER I, V40, P295
  • [7] Accuracy of three-dimensional printed patient-specific drill guides for treatment of canine humeral intracondylar fissure
    Easter, Tim G.
    Bilmont, Alexis
    Pink, Jonathan
    Oxley, Bill
    [J]. VETERINARY SURGERY, 2020, 49 (02) : 363 - 372
  • [8] Clinical use of a new frameless optical neuronavigation system for brain biopsies: 10 cases (2013-2020)
    Gutmann, S.
    Taestensen, C.
    Boettcher, I. C.
    Dietzel, J.
    Loderstedt, S.
    Kohl, S.
    Matiasek, K.
    Flegel, T.
    [J]. JOURNAL OF SMALL ANIMAL PRACTICE, 2022, 63 (06) : 468 - 481
  • [9] Case Report: Clinical Use of a Patient-Individual Magnetic Resonance Imaging-Based Stereotactic Navigation Device for Brain Biopsies in Three Dogs
    Gutmann, Sarah
    Flegel, Thomas
    Mueller, Marcel
    Moebius, Robert
    Matiasek, Kaspar
    Koenig, Florian
    Winkler, Dirk
    Grunert, Ronny
    [J]. FRONTIERS IN VETERINARY SCIENCE, 2022, 9
  • [10] Accuracy of a magnetic resonance imaging-based 3D printed stereotactic brain biopsy device in dogs
    Gutmann, Sarah
    Winkler, Dirk
    Mueller, Marcel
    Moebius, Robert
    Fischer, Jean-Pierre
    Boettcher, Peter
    Kiefer, Ingmar
    Grunert, Ronny
    Flegel, Thomas
    [J]. JOURNAL OF VETERINARY INTERNAL MEDICINE, 2020, 34 (02) : 844 - 851