Cone Beam Computed Tomography Image-Quality Improvement Using "One-Shot" Super-resolution

被引:0
|
作者
Tsuji, Takumasa [1 ]
Yoshida, Soichiro [2 ]
Hommyo, Mitsuki [1 ]
Oyama, Asuka [3 ]
Kumagai, Shinobu [4 ]
Shiraishi, Kenshiro [5 ]
Kotoku, Jun'ichi [1 ,4 ]
机构
[1] Teikyo Univ, Grad Sch Med Care & Technol, 2-11-1 Kaga,Itabashi Ku, Tokyo 1738605, Japan
[2] Univ Tokyo Hosp, Dept Radiol, 7-3-1 Hongo,Bunkyo Ku, Tokyo 1138655, Japan
[3] Osaka Univ, Hlth & Counseling Ctr, Hlth Care Div, 1-7 Machikaneyama, Toyonaka, Osaka 5600043, Japan
[4] Teikyo Univ Hosp, Cent Radiol, 2-11-1 Kaga,Itabashi Ku, Tokyo 1738606, Japan
[5] Teikyo Univ, Sch Med, Dept Radiol, Kaga 2-11-1,Itabashi Ku, Tokyo 1738605, Japan
来源
JOURNAL OF IMAGING INFORMATICS IN MEDICINE | 2024年
基金
日本学术振兴会;
关键词
Cone beam CT; Deep learning; Deformable image registration; One-shot learning; Super-resolution; SCATTER CORRECTION; RADIATION-THERAPY; CT; REGISTRATION; RADIOTHERAPY;
D O I
10.1007/s10278-024-01346-w
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cone beam computed tomography (CBCT) images are convenient representations for obtaining information about patients' internal organs, but their lower image quality than those of treatment planning CT images constitutes an important shortcoming. Several proposed CBCT image-quality improvement methods based on deep learning require large amounts of training data. Our newly developed model using a super-resolution method, "one-shot" super-resolution (OSSR) based on the "zero-shot" super-resolution method, requires only small amounts of training data to improve CBCT image quality using only the target CBCT image and the paired treatment planning CT image. For this study, pelvic CBCT images and treatment planning CT images of 30 prostate cancer patients were used. We calculated the root mean squared error (RMSE), peak signal-to-noise ratio (PSNR), and structural similarity (SSIM) to evaluate image-quality improvement and normalized mutual information (NMI) as a quantitative evaluation of positional accuracy. Our proposed method can improve CBCT image quality without requiring large amounts of training data. After applying our proposed method, the resulting RMSE, PSNR, SSIM, and NMI between the CBCT images and the treatment planning CT images were as much as 0.86, 1.05, 1.03, and 1.31 times better than those obtained without using our proposed method. By comparison, CycleGAN exhibited values of 0.91, 1.03, 1.02, and 1.16. The proposed method achieved performance equivalent to that of CycleGAN, which requires images from approximately 30 patients for training. Findings demonstrated improvement of CBCT image quality using only the target CBCT images and the paired treatment planning CT images.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Improving Medical Image Quality Using a Super-Resolution Technique with Attention Mechanism
    Lee, Dong Yun
    Kim, Jang Yeop
    Cho, Soo Young
    APPLIED SCIENCES-BASEL, 2025, 15 (02):
  • [42] Computed Tomography Super-Resolution Using a Generative Adversarial Network in Bronchoscopy: A Clinical Feasibility Study
    Heng-sheng Chao
    Tsu-Hui Shiao
    Chung-Wei Chou
    Fang-Chi Lin
    Yu-Te Wu
    Der-Ming Liou
    Journal of Medical and Biological Engineering, 2021, 41 : 592 - 598
  • [43] Computed Tomography Super-Resolution Using a Generative Adversarial Network in Bronchoscopy: A Clinical Feasibility Study
    Chao, Heng-sheng
    Shiao, Tsu-Hui
    Chou, Chung-Wei
    Lin, Fang-Chi
    Wu, Yu-Te
    Liou, Der-Ming
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2021, 41 (05) : 592 - 598
  • [44] Experiences with image quality and radiation dose of cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) in pediatric extremity trauma
    Tschauner, Sebastian
    Marterer, Robert
    Nagy, Eszter
    Singer, Georg
    Riccabona, Michael
    Sorantin, Erich
    SKELETAL RADIOLOGY, 2020, 49 (12) : 1939 - 1949
  • [45] QUALITY ASSESSMENT OF FRAMELESS FRACTIONATED STEREOTACTIC RADIOTHERAPY USING CONE BEAM COMPUTED TOMOGRAPHY
    Peng, Lee-Cheng
    Kahler, Darren
    Samant, Sanjiv
    Li, Jonathan
    Amdur, Robert
    Palta, Jatinder R.
    Liu, Chihray
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (05): : 1586 - 1593
  • [46] Image Quality Improvement in Cone-Beam CT Using Deep Learning
    Lei, Yang
    Wang, Tonghe
    Harms, Joseph
    Shafai-Erfani, Ghazal
    Dong, Xue
    Zhou, Jun
    Patel, Pretesh
    Tang, Xiangyang
    Liu, Tian
    Curran, Walter J.
    Higgins, Kristin
    Yang, Xiaofeng
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [47] How image quality affects determination of target displacement when using kilovoltage cone-beam computed tomography
    Oh, Seungjong
    Kim, Siyong
    Suh, Tae-Suk
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (01): : 101 - 107
  • [48] Cone beam computed tomography based image guidance and quality assessment of prostate cancer for magnetic resonance imaging-only radiotherapy in the pelvis
    Edmund, Jens M.
    Andreasen, Daniel
    Van Leemput, Koen
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2021, 18 : 55 - 60
  • [49] Image quality and absorbed dose comparison of single- and dual-source cone-beam computed tomography
    Miura, Hideharu
    Ozawa, Shuichi
    Okazue, Toshiya
    Kawakubo, Atsushi
    Yamada, Kiyoshi
    Nagata, Yasushi
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (03): : 360 - 366
  • [50] Cone beam computed tomography for imaging orbital trauma-image quality and radiation dose compared with conventional multislice computed tomography
    Brisco, Jessica
    Fuller, Karen
    Lee, Nicholas
    Andrew, David
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2014, 52 (01) : 76 - 80