Cone Beam Computed Tomography Image-Quality Improvement Using "One-Shot" Super-resolution

被引:0
|
作者
Tsuji, Takumasa [1 ]
Yoshida, Soichiro [2 ]
Hommyo, Mitsuki [1 ]
Oyama, Asuka [3 ]
Kumagai, Shinobu [4 ]
Shiraishi, Kenshiro [5 ]
Kotoku, Jun'ichi [1 ,4 ]
机构
[1] Teikyo Univ, Grad Sch Med Care & Technol, 2-11-1 Kaga,Itabashi Ku, Tokyo 1738605, Japan
[2] Univ Tokyo Hosp, Dept Radiol, 7-3-1 Hongo,Bunkyo Ku, Tokyo 1138655, Japan
[3] Osaka Univ, Hlth & Counseling Ctr, Hlth Care Div, 1-7 Machikaneyama, Toyonaka, Osaka 5600043, Japan
[4] Teikyo Univ Hosp, Cent Radiol, 2-11-1 Kaga,Itabashi Ku, Tokyo 1738606, Japan
[5] Teikyo Univ, Sch Med, Dept Radiol, Kaga 2-11-1,Itabashi Ku, Tokyo 1738605, Japan
来源
JOURNAL OF IMAGING INFORMATICS IN MEDICINE | 2024年
基金
日本学术振兴会;
关键词
Cone beam CT; Deep learning; Deformable image registration; One-shot learning; Super-resolution; SCATTER CORRECTION; RADIATION-THERAPY; CT; REGISTRATION; RADIOTHERAPY;
D O I
10.1007/s10278-024-01346-w
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Cone beam computed tomography (CBCT) images are convenient representations for obtaining information about patients' internal organs, but their lower image quality than those of treatment planning CT images constitutes an important shortcoming. Several proposed CBCT image-quality improvement methods based on deep learning require large amounts of training data. Our newly developed model using a super-resolution method, "one-shot" super-resolution (OSSR) based on the "zero-shot" super-resolution method, requires only small amounts of training data to improve CBCT image quality using only the target CBCT image and the paired treatment planning CT image. For this study, pelvic CBCT images and treatment planning CT images of 30 prostate cancer patients were used. We calculated the root mean squared error (RMSE), peak signal-to-noise ratio (PSNR), and structural similarity (SSIM) to evaluate image-quality improvement and normalized mutual information (NMI) as a quantitative evaluation of positional accuracy. Our proposed method can improve CBCT image quality without requiring large amounts of training data. After applying our proposed method, the resulting RMSE, PSNR, SSIM, and NMI between the CBCT images and the treatment planning CT images were as much as 0.86, 1.05, 1.03, and 1.31 times better than those obtained without using our proposed method. By comparison, CycleGAN exhibited values of 0.91, 1.03, 1.02, and 1.16. The proposed method achieved performance equivalent to that of CycleGAN, which requires images from approximately 30 patients for training. Findings demonstrated improvement of CBCT image quality using only the target CBCT images and the paired treatment planning CT images.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Improvement of Image Super-resolution Algorithms using Iterative Back Projection
    Blanco Castro E.
    Nakano M.
    Sanchez Perez G.
    Perez Meana H.
    2017, IEEE Computer Society (15): : 2214 - 2219
  • [22] Evaluation of the sparse coding super-resolution method for improving image quality of up-sampled images in computed tomography
    Ota, Junko
    Umehara, Kensuke
    Ishimaru, Naoki
    Ohno, Shunsuke
    Okamoto, Kentaro
    Suzuki, Takanori
    Shirai, Naoki
    Ishida, Takayuki
    MEDICAL IMAGING 2017: IMAGE PROCESSING, 2017, 10133
  • [23] Medical Diagnosis Improvement through Image Quality Enhancement Based on Super-Resolution
    Villanueva, Lara G.
    Callico, Gustavo M.
    Tobajas, Felix
    Lopez, Sebastian
    De Armas, Valentin
    Lopez, Jose F.
    Sarmiento, Roberto
    13TH EUROMICRO CONFERENCE ON DIGITAL SYSTEM DESIGN: ARCHITECTURES, METHODS AND TOOLS, 2010, : 259 - 262
  • [24] Improving linac integrated cone beam computed tomography image quality using tube current modulation
    Stankovic, Uros
    Ploeger, Lennert S.
    Sonke, Jan-Jakob
    MEDICAL PHYSICS, 2021, 48 (04) : 1739 - 1749
  • [25] Estimation of Rectal Dose Using Daily Megavoltage Cone-Beam Computed Tomography and Deformable Image Registration
    Akino, Yuichi
    Yoshioka, Yasuo
    Fukuda, Shoichi
    Maruoka, Shintaroh
    Takahashi, Yutaka
    Yagi, Masashi
    Mizuno, Hirokazu
    Isohashi, Fumiaki
    Ogawa, Kazuhiko
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (03): : 602 - 608
  • [26] Image Quality Improvement in Computed Tomography using Anisotropic Diffusion
    Raut, Vrushali N.
    Ruikar, Sachin D.
    2013 IEEE INTERNATIONAL CONFERENCE ON EMERGING TRENDS IN COMPUTING, COMMUNICATION AND NANOTECHNOLOGY (ICE-CCN'13), 2013, : 601 - 605
  • [27] Dose and Image Quality of Cone-Beam Computed Tomography as Compared With Conventional Multislice Computed Tomography in Abdominal Imaging
    Schegerer, Alexander A.
    Lechel, Ursula
    Ritter, Manuel
    Weisser, Gerald
    Fink, Christian
    Brix, Gunnar
    INVESTIGATIVE RADIOLOGY, 2014, 49 (10) : 675 - 684
  • [28] Cone-beam computed tomography (CBCT) dose optimization technique and image quality assessment scoring
    Trivedi, Gaurav
    Singh, Pushpendra P.
    Oinam, Arun S.
    Singh, Ranjit
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2024, 20 (01) : 71 - 78
  • [29] A comparative study for image quality and radiation dose of a cone beam computed tomography scanner and a multislice computed tomography scanner for paranasal sinus imaging
    De Cock, Jens
    Zanca, Federica
    Canning, John
    Pauwels, Ruben
    Hermans, Robert
    EUROPEAN RADIOLOGY, 2015, 25 (07) : 1891 - 1900
  • [30] Investigation of effect of reconstruction filters on cone-beam computed tomography image quality
    Kavitha Srinivasan
    Mohammad Mohammadi
    Justin Shepherd
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 607 - 614