Impact of scanning interruptions on accuracy of implant-supported full-arch scans: An in-vitro pilot study

被引:3
作者
Limones, Alvaro [1 ,2 ]
Cakmak, Gulce [3 ]
Fonseca, Manrique [3 ]
Roccuzzo, Andrea [4 ,5 ,6 ]
Cobo-Vazquez, Carlos [7 ]
Gomez-Polo, Miguel [1 ]
Molinero-Mourelle, Pedro [1 ,3 ]
机构
[1] Univ Complutense Madrid, Fac Dent, Dept Conservat Dent & Prosthodont, Madrid, Spain
[2] Indiana Univ, Sch Dent, Dept Prosthodont, Indianapolis, IN USA
[3] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3010 Bern, Switzerland
[4] Univ Bern, Sch Dent Med, Dept Periodontol, Freiburgstr 7, CH-3010 Bern, Switzerland
[5] Univ Bern, Sch Dent Med, Unit Practice Based Res, Bern, Switzerland
[6] Copenhagen Univ Hosp, Rigshosp, Dept Oral & Maxillofacial Surg, Copenhagen, Denmark
[7] Univ Complutense Madrid, Fac Dent, Dept Dent Clin Specialties, Madrid, Spain
关键词
Intraoral scanner; Digital impression; Dental implants; Accuracy; Trueness; Precision; INTRAORAL SCANNERS; IMPRESSIONS; EXPERIENCE;
D O I
10.1016/j.jdent.2024.105503
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To assess the impact of involuntary interruptions (simulating tracking loss by moving the scanner out of its focal distance) and voluntary interruptions (pressing the scanner's turn-on button) on the accuracy of implant-supported full-arch scans using an intraoral scanner (TRIOS 5, version 22.1.10; 3Shape; Copenhagen, Denmark). Materials and methods: An edentulous model with four implants was digitized with an industrial scanner (Artec Micro II; Artec 3D) to create a reference scan. Four groups (n = 30) were established based on the number of interruptions during scanning: Zero Group (no interruptions; control group), 6-V Group (six voluntary interruptions), 6-I Group (six involuntary interruptions), and 12-I Group (twelve involuntary interruptions). Primary outcome was accuracy assessed by the Root Mean Square (RMS) method. Secondary outcomes included scanning time and the number of photograms. Data were analyzed using one-way ANOVA and post hoc Tukey multiple comparison tests (alpha=0.05). Results: A total of 120 digital scans were conducted. The Zero group achieved a RMS error of 291 +/- 47 mu m, a scanning time of 68 +/- 6s, and 1320 +/- 129 photograms. 6-V group significantly reduced RMS error (MD -102 mu m [IC 95 %: -141, -63]), decreased scanning time (MD -20s [IC 95 %: -25, -17]), and reduced photograms (MD -415 photograms [IC 95 %: -506, -324]) compared to the control group (P<.001). Simulations of 6 or 12 involuntary interruptions did not affect accuracy compared to the control group (P>.05). Conclusions: Voluntary interruptions during scanning, achieved by pressing the scanner's turn-on button, appear to enhance accuracy due to image preprocessing, while involuntary interruptions had no significant impact on the accuracy of implant-supported full-arch scans.
引用
收藏
页数:7
相关论文
共 42 条
[11]   In Vitro Accuracy of Digital and Conventional Impressions for Full-Arch Implant-Supported Prostheses [J].
D'haese, Rani ;
Vrombaut, Tom ;
Roeykens, Herman ;
Vandeweghe, Stefan .
JOURNAL OF CLINICAL MEDICINE, 2022, 11 (03)
[12]   Intraoral Digital Impression Technique Compared to Conventional Impression Technique. A Randomized Clinical Trial [J].
Gjelvold, Bjorn ;
Chrcanovic, Bruno Ramos ;
Korduner, Eva-Karin ;
Collin-Bagewitz, Ingrid ;
Kisch, Jeno .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (04) :282-287
[13]   Accuracy, scanning time, and patient satisfaction of stereophotogrammetry systems for acquiring 3D dental implant positions: A systematic review [J].
Gomez-Polo, Miguel ;
Barmak, Abdul B. ;
Ortega, Rocio ;
Rutkunas, Vygandas ;
Kois, John C. ;
Revilla-Leon, Marta .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 :208-224
[14]   Influence of arch location and scanning pattern on the scanning accuracy, scanning time, and number of photograms of complete-arch intraoral digital implant scans [J].
Gomez-Polo, Miguel ;
Cascos, Rocio ;
Ortega, Rocio ;
Barmak, Abdul B. ;
Kois, John C. ;
Revilla-Leon, Marta .
CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (06) :591-601
[15]   Conventional and digital complete arch implant impression techniques: An in vitro study comparing accuracy [J].
Gomez-Polo, Miguel ;
Sallorenzo, Alessandro ;
Cascos, Rocio ;
Ballesteros, Juan ;
Barmak, Abdul B. ;
Revilla-Leon, Marta .
JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (04) :809-818
[16]  
Gómez-Polo M, 2021, INT J COMPUT DENT, V24, P117
[17]   Guided implant scanning: A procedure for improving the accuracy of implant-supported complete-arch fixed dental prostheses [J].
Gomez-Polo, Miguel ;
Ballesteros, Juan ;
Perales-Padilla, Pedro ;
Perales-Pulido, Pedro ;
Gomez-Polo, Cristina ;
Ortega, Rocio .
JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (02) :135-139
[18]   Accuracy, reliability, and efficiency of intraoral scanners for full-arch impressions: a systematic review of the clinical evidence [J].
Goracci, Cecilia ;
Franchi, Lorenzo ;
Vichi, Alessandro ;
Ferrari, Marco .
EUROPEAN JOURNAL OF ORTHODONTICS, 2016, 38 (04) :422-428
[19]   Influence of scanning protocol on the accuracy of complete-arch digital implant scans: An in vitro study [J].
Hamilton, Adam ;
Negreiros, William Matthew ;
Jain, Shruti ;
Finkelman, Matthew ;
Gallucci, German O. .
CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (06) :641-651
[20]  
Jemt T, 1996, Int J Oral Maxillofac Implants, V11, P620