Impact of scanning interruptions on accuracy of implant-supported full-arch scans: An in-vitro pilot study

被引:3
作者
Limones, Alvaro [1 ,2 ]
Cakmak, Gulce [3 ]
Fonseca, Manrique [3 ]
Roccuzzo, Andrea [4 ,5 ,6 ]
Cobo-Vazquez, Carlos [7 ]
Gomez-Polo, Miguel [1 ]
Molinero-Mourelle, Pedro [1 ,3 ]
机构
[1] Univ Complutense Madrid, Fac Dent, Dept Conservat Dent & Prosthodont, Madrid, Spain
[2] Indiana Univ, Sch Dent, Dept Prosthodont, Indianapolis, IN USA
[3] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Freiburgstr 7, CH-3010 Bern, Switzerland
[4] Univ Bern, Sch Dent Med, Dept Periodontol, Freiburgstr 7, CH-3010 Bern, Switzerland
[5] Univ Bern, Sch Dent Med, Unit Practice Based Res, Bern, Switzerland
[6] Copenhagen Univ Hosp, Rigshosp, Dept Oral & Maxillofacial Surg, Copenhagen, Denmark
[7] Univ Complutense Madrid, Fac Dent, Dept Dent Clin Specialties, Madrid, Spain
关键词
Intraoral scanner; Digital impression; Dental implants; Accuracy; Trueness; Precision; INTRAORAL SCANNERS; IMPRESSIONS; EXPERIENCE;
D O I
10.1016/j.jdent.2024.105503
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To assess the impact of involuntary interruptions (simulating tracking loss by moving the scanner out of its focal distance) and voluntary interruptions (pressing the scanner's turn-on button) on the accuracy of implant-supported full-arch scans using an intraoral scanner (TRIOS 5, version 22.1.10; 3Shape; Copenhagen, Denmark). Materials and methods: An edentulous model with four implants was digitized with an industrial scanner (Artec Micro II; Artec 3D) to create a reference scan. Four groups (n = 30) were established based on the number of interruptions during scanning: Zero Group (no interruptions; control group), 6-V Group (six voluntary interruptions), 6-I Group (six involuntary interruptions), and 12-I Group (twelve involuntary interruptions). Primary outcome was accuracy assessed by the Root Mean Square (RMS) method. Secondary outcomes included scanning time and the number of photograms. Data were analyzed using one-way ANOVA and post hoc Tukey multiple comparison tests (alpha=0.05). Results: A total of 120 digital scans were conducted. The Zero group achieved a RMS error of 291 +/- 47 mu m, a scanning time of 68 +/- 6s, and 1320 +/- 129 photograms. 6-V group significantly reduced RMS error (MD -102 mu m [IC 95 %: -141, -63]), decreased scanning time (MD -20s [IC 95 %: -25, -17]), and reduced photograms (MD -415 photograms [IC 95 %: -506, -324]) compared to the control group (P<.001). Simulations of 6 or 12 involuntary interruptions did not affect accuracy compared to the control group (P>.05). Conclusions: Voluntary interruptions during scanning, achieved by pressing the scanner's turn-on button, appear to enhance accuracy due to image preprocessing, while involuntary interruptions had no significant impact on the accuracy of implant-supported full-arch scans.
引用
收藏
页数:7
相关论文
共 42 条
[1]   Effect of relative humidity on the accuracy, scanning time, and number of photograms of dentate complete arch intraoral digital scans [J].
Agustin-Panadero, Ruben ;
Estada, Maria Isabel Clemente ;
Perez-Barquero, Jorge Alonso ;
Zubizarreta-Macho, Alvaro ;
Revilla-Leon, Marta ;
Gomez-Polo, Miguel .
JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (03) :865-871
[2]   User Experience of Intraoral Scanners in Dentistry: Transnational Questionnaire Study [J].
Al-Hassiny, Ahmad ;
Vegh, Daniel ;
Banyai, Dorottya ;
Vegh, Adam ;
Geczi, Zoltan ;
Borbely, Judit ;
Hermann, Peter ;
Hegedus, Tamas .
INTERNATIONAL DENTAL JOURNAL, 2023, 73 (05) :754-759
[3]   Applicability and accuracy of an intraoral scanner for scanning multiple implants in edentulous mandibles: A pilot study [J].
Andriessen, Frank S. ;
Riikens, David R. ;
van der Meer, Wither J. ;
Wismeijer, Daniell W. .
JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (03) :186-194
[4]   Accuracy of digital impressions for implant-supported complete-arch prosthesis when using an auxiliary geometry device [J].
Arikan, Hale ;
Muhtarogullari, Mehmet ;
Uzel, Sema Merve ;
Guncu, Mustafa Baris ;
Aktas, Guliz ;
Marshall, Lindsay Simone ;
Turkyilmaz, Ilser .
JOURNAL OF DENTAL SCIENCES, 2023, 18 (02) :808-813
[5]  
Assif D, 1996, Int J Oral Maxillofac Implants, V11, P216
[6]   Fixed Rehabilitation of the Edentulous Maxilla: Possibilities and Clinical Outcome [J].
Att, Wael ;
Bernhart, Jasmin ;
Strub, Joerg Rudolf .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 67 (11) :60-73
[7]   Use of the universal scan template to achieve a predictable optical impression: Preliminary data of a case series study in complete edentulous patients [J].
Campana, Veronica ;
Papa, Andrea ;
Silvetti, Manuel Amilcare ;
Del Fabbro, Massimo ;
Testori, Tiziano .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (01) :237-244
[8]   Trueness of Intraoral Scanners Considering Operator Experience and Three Different Implant Scenarios: A Preliminary Report [J].
Canullo, Luigi ;
Colombo, Marco ;
Menini, Maria ;
Sorge, Patrizia ;
Pesce, Paolo .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2021, 34 (02) :250-253
[9]   Accuracy of edentulous full-arch implant impression: An in vitro comparison between conventional impression, intraoral scan with and without splinting, and photogrammetry [J].
Cheng, Jing ;
Zhang, Haidong ;
Liu, Hailin ;
Li, Junying ;
Wang, Hom-Lay ;
Tao, Xian .
CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (05) :560-572
[10]   In vitro assessment of the accuracy of digital impressions prepared using a single system for full-arch restorations on implants [J].
Ciocca, Leonardo ;
Meneghello, Roberto ;
Monaco, Carlo ;
Savio, Gianpaolo ;
Scheda, Lorenzo ;
Gatto, Maria Rosaria ;
Baldissara, Paolo .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2018, 13 (07) :1097-1108