Motion artifact variability in biomagnetic wearable devices

被引:0
|
作者
Arekhloo, Negin Ghahremani [1 ,2 ]
Wang, Huxi [1 ,2 ]
Parvizi, Hossein [2 ]
Tanwear, Asfand [1 ]
Zuo, Siming [1 ]
McKinlay, Michael [2 ]
Nunez, Carlos Garcia [2 ]
Nazarpour, Kianoush [1 ,3 ]
Heidari, Hadi [1 ,2 ]
机构
[1] Neuranics Ltd, Glasgow, Scotland
[2] Univ Glasgow, James Watt Sch Engn, Microelect Lab, Glasgow City, Scotland
[3] Univ Edinburgh, Sch Informat, Edinburgh, Scotland
来源
FRONTIERS IN MEDICAL TECHNOLOGY | 2024年 / 6卷
基金
英国工程与自然科学研究理事会;
关键词
biomagnetic measurements; motion artifacts; wearable sensors; gradient background field; homogeneous background field; SIGNAL; ECG;
D O I
10.3389/fmedt.2024.1457535
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Motion artifacts can be a significant noise source in biomagnetic measurements when magnetic sensors are not separated from the signal source. In ambient environments, motion artifacts can be up to ten times stronger than the desired signals, varying with environmental conditions. This study evaluates the variability of these artifacts and the effectiveness of a gradiometer in reducing them in such settings. To achieve these objectives, we first measured the single channel output in varying magnetic field conditions to observe the effect of homogeneous and gradient background fields. Our analysis revealed that the variability in motion artifact within an ambient environment is primarily influenced by the gradient magnetic field rather than the homogeneous one. Subsequently, we configured a gradiometer in parallel and vertical alignment with the direction of vibration (X-axis). Our findings indicated that in a gradient background magnetic field ranging from 1 nT/mm to 10 nT/mm, the single-channel sensor output exhibited a change of 164.97 pT per mm unit increase, while the gradiometer output showed a change of only 0.75 pT/mm within the same range. Upon repositioning the gradiometer vertically (Y direction), perpendicular to the direction of vibration, the single-channel output slope increased to 196.85 pT, whereas the gradiometer output only increased by 1.06 pT/mm for the same range. Our findings highlight the influence of ambient environments on motion artifacts and demonstrate the potential of gradiometers to mitigate these effects. In the future, we plan to record biomagnetic signals both inside and outside the shielded room to compare the efficacy of different gradiometer designs under varying environmental conditions.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] A new particle filter algorithm filtering motion artifact noise for clean electrocardiogram signals in wearable health monitoring system
    Ma, Min
    Du, Mingrui
    Feng, Qiuyue
    Xiahou, Shiji
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (01)
  • [22] Skin-Induced Motion Artifact Removal for Ambulatory Electrocardiography
    He, Zhuobiao
    Min, Hao
    IEEE SENSORS JOURNAL, 2022, 22 (15) : 15033 - 15043
  • [23] Correlation Analysis of Heart Rate Variability between PPG and ECG for Wearable Devices in Different Postures
    Hsiao, Chun-Chieh
    Hsu, Fang-Wei
    Lee, Ren-Guey
    Lin, Robert
    2017 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2017, : 2957 - 2962
  • [24] Modeling of motion artifacts on PPG signals for heart-monitoring using wearable devices.
    Andres Cajas, Sebastian
    Alejandra Landinez, Maria
    Mauricio Lopez, Diego
    15TH INTERNATIONAL SYMPOSIUM ON MEDICAL INFORMATION PROCESSING AND ANALYSIS, 2020, 11330
  • [25] Motion artifact reduction with predictive gating
    Hsieh, J
    ADAPTIVE COMPUTING: MATHEMATICAL AND PHYSICAL METHODS FOR COMPLEX ENVIRONMENTS, 1996, 2824 : 22 - 30
  • [26] Adaptive motion artifact suppression in CT
    Hsieh, J
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XIX, 1996, 2847 : 429 - 437
  • [27] Strain-Isolating Materials and Interfacial Physics for Soft Wearable Bioelectronics and Wireless, Motion Artifact-Controlled Health Monitoring
    Rodeheaver, Nathan
    Herbert, Robert
    Kim, Yun-Soung
    Mahmood, Musa
    Kim, Hojoong
    Jeong, Jae-Woong
    Yeo, Woon-Hong
    ADVANCED FUNCTIONAL MATERIALS, 2021, 31 (36)
  • [28] A Novel Method for Automatic Identification of Motion Artifact Beats in ECG Recordings
    Yuewen Tu
    Xiuquan Fu
    Dingli Li
    Chao Huang
    Yawei Tang
    Shuming Ye
    Hang Chen
    Annals of Biomedical Engineering, 2012, 40 : 1917 - 1928
  • [29] Wearable Devices for Assessment of Tremor
    Vescio, Basilio
    Quattrone, Andrea
    Nistico, Rita
    Crasa, Marianna
    Quattrone, Aldo
    FRONTIERS IN NEUROLOGY, 2021, 12
  • [30] A Survey of Wearable Devices and Challenges
    Seneviratne, Suranga
    Hu, Yining
    Tham Nguyen
    Lan, Guohao
    Khalifa, Sara
    Thilakarathna, Kanchana
    Hassan, Mahbub
    Seneviratne, Aruna
    IEEE COMMUNICATIONS SURVEYS AND TUTORIALS, 2017, 19 (04): : 2573 - 2620