Paul versus Baerveldt 350 glaucoma drainage implants: One-year comparative analysis

被引:0
|
作者
Oliver-Gutierrez, David [1 ,2 ]
Segura-Duch, Gloria [1 ,3 ]
avila-Marron, Elena [1 ]
Arciniegas-Perasso, Carlos A. [1 ]
Duch-Tuesta, Susana [1 ]
机构
[1] VERTE ICO Ophthalmol, Via Augusta 61, Barcelona 08006, Spain
[2] Univ Hosp Valle Hebron, Paseo Valle Hebron 119-129, Barcelona 08035, Spain
[3] Univ Autonoma Barcelona, Inst Univ Barraquer, Ctr Oftalmol Barraquer, C-Muntaner 314, Barcelona 08021, Spain
关键词
Baerveldt glaucoma implant; glaucoma drainage implants; Paul glaucoma implant; refractory glaucoma; tube surgery; VALVE IMPLANTATION; MITOMYCIN-C; SURGERY; OUTCOMES; TUBE;
D O I
10.4103/IJO.IJO_2595_24
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:This study aimed to evaluate and compare the effectiveness and safety of Paul glaucoma implant (PGI) and Baerveldt 350 glaucoma implant (BGI) over a 1-year follow-up period. Methods:This retrospective study was conducted in a private clinic. It compared 27 patients consecutively treated with the PGI to a historical cohort of 29 eyes that received the BGI prior to the introduction of the PGI between 2018 and 2023. Intervention: A new drainage device, the Paul implant, was placed in the anterior or posterior chamber of eyes with uncontrolled intraocular pressure (IOP). Main Outcome Measures:The main outcome measures were success rate, final mean IOP, IOP reduction percentage, medication reduction, and complications. Statistical analyses, including adjustments for confounders, were used to compare the performance of PGI and BGI over at least a 12-month period. Results:Significant reductions in IOP were observed in both groups (P < 0.001). At 1 year, no significant differences were found in mean IOP (BGI: 12.0 mmHg, SD 2.9; PGI: 11.2 mmHg, SD 6.0) or medication usage (P > 0.05). The failure rates were 7% for BGI and 18% for PGI, with complete success rates of 56% for BGI and 32% for PGI. Hypertensive phases occurred in 32% of the BGI cases and in 19% of the PGI cases. No significant differences in the complication rates or postoperative visual acuity were observed between the groups. Conclusion:PGI and BGI exhibited comparable efficacy and safety profiles after 1 year.
引用
收藏
页码:S317 / S323
页数:7
相关论文
共 50 条
  • [41] Myopia correction with transepithelial photorefractive keratectomy versus femtosecond - assisted laser in situ keratomileusis: One-year case-matched analysis
    Luger, Michiel H. A.
    Ewering, Tobias
    Arba-Mosquera, Samuel
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (11) : 1579 - 1587
  • [42] One-year results of two-site trabeculotomy in paediatric glaucoma following cataract surgery
    El Sayed, Yasmine M.
    Elhusseiny, Abdelrahman M.
    Gawdat, Ghada I.
    Elhilali, Hala M.
    EYE, 2021, 35 (06) : 1637 - 1643
  • [43] Epidural Anesthesia for Fetoscopy Retrospective Analysis of a One-year Cohort
    Kiefer, N.
    Suter, S. F.
    Berg, C.
    Gembruch, U.
    Weber, S. U.
    ANAESTHESIST, 2017, 66 (01): : 28 - 33
  • [44] Ab-Externo MicroShunt versus Trabeculectomy in Primary Open-Angle Glaucoma One-Year Results from a 2-Year Randomized, Multicenter Study
    Baker, N. Douglas
    Barnebey, Howard S.
    Moster, Marlene R.
    Stiles, Michael C.
    Vold, Steven D.
    Khatana, Anup K.
    Flowers, Brian E.
    Grover, Davinder S.
    Strouthidis, Nicholas G.
    Panarelli, Joseph F.
    OPHTHALMOLOGY, 2021, 128 (12) : 1710 - 1721
  • [45] A comparative study of cystoid macula edema following glaucoma drainage device surgery versus trabeculectomy
    Gietzelt, Caroline
    Koenig, Lilo
    Adler, Werner
    Schaub, Friederike
    Heindl, Ludwig M.
    Cursiefen, Claus
    Dietlein, Thomas S.
    Enders, Philip
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)
  • [46] A one-year cost-utility analysis of REBOA versus RTACC for non-compressible torso haemorrhage
    Renna, Maxwell S.
    van Zeller, Cristiano
    Abu-Hijleh, Farah
    Tong, Cherlyn
    Gambini, Jasmine
    Ma, Mengyao
    TRAUMA-ENGLAND, 2019, 21 (01): : 45 - 54
  • [47] One-year follow-up of the XEN® implant with mitomycin-C in pseudoexfoliative glaucoma patients
    Ibanez-Munoz, Ana
    Santiago Soto-Biforcos, Victor
    Chacon-Gonzalez, Maria
    Rua-Galisteo, Oscar
    Arrieta-Los Santos, Alexandra
    Ester Lizuain-Abadia, Maria
    Del Rio Mayor, Jose Luis
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2019, 29 (03) : 309 - 314
  • [48] Two-stage intra-tenon injection versus sponge-applied mitomycin C-augmented trabeculectomy: a one-year study
    Shih, En-Jie
    Chen, Ying-Ying
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (08) : 2593 - 2603
  • [49] One-Year Results of Stab Incision Glaucoma Surgery and Radiofrequency-Assisted Stab Incision in Management of Open-Angle Glaucoma
    Salama, Marwa Metwally
    Abdel-Hamid, Rehab Mahmoud
    El-Basty, Mohamed Karam
    El-Zawahry, Omar Mohamed
    MIDDLE EAST AFRICAN JOURNAL OF OPHTHALMOLOGY, 2019, 26 (03) : 141 - 147
  • [50] Immunohistochemical analysis of extracellular matrix bleb capsules of functioning and non-functioning glaucoma drainage implants
    Valimaki, Juha
    Uusitalo, Hannu
    ACTA OPHTHALMOLOGICA, 2014, 92 (06) : 524 - 528