Free-running 5D whole-heart MRI for isotropic cardiac function measurements at 3T without contrast agents

被引:0
|
作者
Ogier, Augustin C. [1 ,2 ]
Quesada, Isabel Monton [1 ,2 ]
Sieber, Xavier [1 ,2 ]
Calarnou, Pauline [1 ,2 ]
Ledoux, Jean-Baptiste [1 ,2 ,3 ]
Milani, Bastien [1 ,2 ]
Antiochos, Panagiotis [2 ,4 ]
Schwitter, Juerg [2 ,4 ]
Roy, Christopher W. [1 ,2 ]
Yerly, Jerome [1 ,2 ,3 ]
Stuber, Matthias [1 ,2 ,3 ]
van Heeswijk, Ruud B. [1 ,2 ]
机构
[1] Lausanne Univ Hosp CHUV, Dept Radiol, Rue Bugnon 46,BH 8-84, CH-1011 Lausanne, Switzerland
[2] Univ Lausanne UNIL, Lausanne, Switzerland
[3] CIBM Ctr Biomed Imaging, Lausanne, Switzerland
[4] Lausanne Univ Hosp CHUV, Heart & Vessel Dept, Lausanne, Switzerland
关键词
3T; 5D whole-heart MRI; compressed sensing; contrast-agent-free; free-running; non-rigid motion correction; T-2 preparation pulse; T-2; PREPARATION; CORONARY; ANGIOGRAPHY;
D O I
10.1002/mrm.30469
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To optimize and characterize an interrupted 5D free-running framework at 3 T for detailed cardiac function assessment without the use of breath holding or contrast agents. Methods: A free-running 3D radial gradient echo sequence was periodically interrupted with a T2 preparation and a recovery module to optimize native blood-to-myocardium contrast at 3 T. Lipid signal was suppressed using a numerically optimized water-excitation RF pulse to reduce lipid streaking artifacts and to improve overall image quality. Optimal acquisition parameters were established for a 5-min scan time using extended phase graph simulations. A compressed sensing-based reconstruction incorporating cardiac and respiratory inter-bin deformation fields was employed to generate 5D images of the whole heart. The sharpness and contrast between the left ventricular blood pool and myocardium, along with the functional measurements of the left ventricle from the 5D datasets, were compared to routine 2D cine imaging in 16 healthy volunteers and three patients referred for clinically indicated CMR. Results: The proposed method resulted in lower contrast (0.57 +/- 0.12 vs. 2.09 +/- 0.74,p <0.001) and sharpness (3.76 +/- 1.11 mm vs. 2.74 +/- 0.95 mm, p <0.001), but enabled similar left-ventricle ejection fraction assessment (bias = 1.3%, limits of agreement = [-3.3%, 5.9%], intraclass correlation coefficient = 0.87,p = 0.03) with high reproducibility compared to 2D cine. Conclusion: The proposed contrast-free, interrupted free-running 5D imaging provides left ventricular functional assessments comparable to 2D cine at 3 T, while offering an improved patient experience through shorter scan times and free breathing.
引用
收藏
页码:2386 / 2400
页数:15
相关论文
共 13 条
  • [11] Pilot tone navigation for respiratory and cardiac motion-resolved free-running 5D flow MRI
    Falcao, Mariana B. L.
    Di Sopra, Lorenzo
    Ma, Liliana
    Bacher, Mario
    Yerly, Jerome
    Speier, Peter
    Rutz, Tobias
    Prsa, Milan
    Markl, Michael
    Stuber, Matthias
    Roy, Christopher W.
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (02) : 718 - 732
  • [12] Accelerated free-breathing whole-heart 3D T2 mapping with high isotropic resolution
    Bustin, Aurelien
    Milotta, Giorgia
    Ismail, Tevfik F.
    Neji, Radhouene
    Botnar, Rene M.
    Prieto, Claudia
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (03) : 988 - 1002
  • [13] How low can we go? The effect of acquisition duration on cardiac volume and function measurements in free-running cardiac and respiratory motion-resolved five-dimensional whole-heart cine magnetic resonance imaging at 1.5T
    Holtackers, Robert J.
    Ogier, Augustin C.
    Romanin, Ludovica
    Tenisch, Estelle
    Quesada, Isabel Monton
    van Heeswijk, Ruud B.
    Roy, Christopher W.
    Yerly, Jerome
    Prsa, Milan
    Stuber, Matthias
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2025, 27 (01)