Clinical outcomes of a toric continuous range of vision presbyopia-correcting intraocular lens

被引:0
|
作者
Orbegozo, Javier [1 ]
Perez, Angelica [1 ]
Basterra, Inaki [1 ]
Noguera, Helena [1 ]
Gonzalez, Laura [2 ,3 ]
Lauzirika, Gorka [2 ,4 ]
Pinero, David P. [5 ]
机构
[1] Miranza COI Bilbao, Ctr Oftalmol Integral Bilbao Berri SL, C Rodriguez Arias 6 2 Dep 205, Bilbao 48008, Spain
[2] Dept Miranza Grp, Barcelona, Spain
[3] Miranza Grp, Inst Microcirugia Ocular IMO Barcelona, Barcelona, Spain
[4] Miranza Begitek, Donostia San Sebastian, Spain
[5] Univ Alicante, Dept Opt Pharmacol & Anat, Crta San Vicente Raspeig S-N, Alicante 03016, Spain
关键词
PATIENT SATISFACTION; VISUAL OUTCOMES; EXCHANGE; ASTIGMATISM; IMPLANTATION; ACUITY; EYES;
D O I
10.1097/j.jcrs.0000000000001428
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the clinical outcomes of the toric version of a presbyopia-correcting intraocular lens (IOL) based on the combination of a diffractive-based extended depth-of-focus (EDOF) pattern and a diffractive multifocal platform. Setting: Miranza COI Bilbao, Bilbao, Spain. Design: Prospective case series. Methods: 35 patients (51 to 84 years) with corneal astigmatism ranging from 0.75 to 2.19 diopters (D) undergoing bilateral cataract surgery with implantation of the Synergy Toric II IOL were evaluated during a 3-month follow-up. Visual acuity, refraction, defocus curve, and patient-reported outcomes with the Catquest-9SF questionnaire were analyzed. A vectorial analysis was used to analyze the accuracy of astigmatic correction. Results: Mean 3-month monocular postoperative uncorrected distance, intermediate (80 cm) and near (40 cm) visual acuities were 0.06 +/- 0.11 logMAR, 0.13 +/- 0.12 logMAR, and 0.13 +/- 0.09 logMAR, respectively. Mean monocular distance-corrected intermediate (80 cm) and near visual acuity (40 cm) were 0.11 +/- 0.12 logMAR and 0.10 +/- 0.10 logMAR, respectively. Mean binocular defocus curve showed visual acuities of 0.10 logMAR or better for defocus levels from +0.50 to -2.50 D. Residual cylinder was within +/- 0.50 D in 97.0% of eyes. The surgically induced astigmatism prediction error ranged between -0.49 D and 0.50 D, with a mean value of 0.04 +/- 0.16 D. Mean absolute IOL rotation was 3.79 +/- 2.94 degrees. Significant improvements were found in all Rasch-calibrated scores obtained with Catquest-9SF (P < .001). Conclusions: The implantation of the toric presbyopia-correcting IOL evaluated provides an efficacious astigmatic correction while providing a fully restoration of the visual function across different distances.
引用
收藏
页码:724 / 732
页数:9
相关论文
共 50 条
  • [31] Comparing pupil-dependent image quality across presbyopia-correcting intraocular lenses
    Pepose, Jay S.
    Altmann, Griffith E.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (06) : 1060 - 1062
  • [32] Bifocal nondiffractive intraocular lens for enhanced depth of focus in correcting presbyopia: Clinical evaluation
    Vounotrypidis, Efstathios
    Diener, Raphael
    Wertheimer, Christian
    Kreutzer, Thomas
    Wolf, Armin
    Priglinger, Siegfried
    Mayer, Wolfgang I.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (05) : 627 - 632
  • [33] Characterizing glare effects associated with diffractive optics in presbyopia-correcting intraocular lenses
    Labuz, Grzegorz
    Khoramnia, Ramin
    Yan, Weijia
    van den Berg, Thomas J. T. P.
    Auffarth, Gerd U.
    Naujokaitis, Tadas
    Tandogan, Tamer
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (04) : 413 - 419
  • [34] Comparison of Through-Focus Image Sharpness Across Five Presbyopia-Correcting Intraocular Lenses
    Pepose, Jay S.
    Wang, Daozhi
    Altmann, Griffith E.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 154 (01) : 20 - 28
  • [35] Comparison of Clinical Outcomes, Visual Quality and Visual Function of Two Presbyopia-Correcting Intraocular Lenses Made from the Same Material, but with Different Design and Optics
    Novacek, Ladislav Viktor
    Nemcova, Marie
    Tyx, Katerina
    Lahodova, Kristyna
    Rejmont, Leos
    Rozsival, Pavel
    Studeny, Pavel
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (15)
  • [36] Clinical outcomes of new toric trifocal diffractive intraocular lens in patients with cataract and stable keratoconus Six months follow-up
    Farideh, Doroodgar
    Azad, Sanginabadi
    Feizollah, Niazi
    Sana, Niazi
    Cyrus, Alinia
    Mohammad, Ghoreishi
    Alireza, Baradaran-rafii
    MEDICINE, 2017, 96 (12)
  • [37] A Novel Concept of Correcting Presbyopia: First Clinical Results with a Phakic Diffractive Intraocular Lens
    Schmid, Ruediger
    Luedtke, Holger
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 2011 - 2019
  • [38] Comparative Analysis of the Clinical Outcomes With a Monofocal and an Extended Range of Vision Intraocular Lens
    Pedrotti, Emilio
    Bruni, Enrico
    Bonacci, Erika
    Badalamenti, Rosanna
    Mastropasqua, Rodolfo
    Marchini, Giorgio
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (07) : 436 - +
  • [39] Clinical outcomes of a new extended range of vision intraocular lens: International Multicenter Concerto Study
    Cochener, Beatrice
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (09) : 1268 - 1275
  • [40] Comparison of the Clinical Outcomes of Two Types of Toric Intraocular Lens
    Yang, Soon Won
    Lee, Jae Hoon
    Lim, Sung A.
    Chung, So Hyang
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (02): : 200 - 207