Clinical outcomes of a toric continuous range of vision presbyopia-correcting intraocular lens

被引:0
|
作者
Orbegozo, Javier [1 ]
Perez, Angelica [1 ]
Basterra, Inaki [1 ]
Noguera, Helena [1 ]
Gonzalez, Laura [2 ,3 ]
Lauzirika, Gorka [2 ,4 ]
Pinero, David P. [5 ]
机构
[1] Miranza COI Bilbao, Ctr Oftalmol Integral Bilbao Berri SL, C Rodriguez Arias 6 2 Dep 205, Bilbao 48008, Spain
[2] Dept Miranza Grp, Barcelona, Spain
[3] Miranza Grp, Inst Microcirugia Ocular IMO Barcelona, Barcelona, Spain
[4] Miranza Begitek, Donostia San Sebastian, Spain
[5] Univ Alicante, Dept Opt Pharmacol & Anat, Crta San Vicente Raspeig S-N, Alicante 03016, Spain
关键词
PATIENT SATISFACTION; VISUAL OUTCOMES; EXCHANGE; ASTIGMATISM; IMPLANTATION; ACUITY; EYES;
D O I
10.1097/j.jcrs.0000000000001428
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the clinical outcomes of the toric version of a presbyopia-correcting intraocular lens (IOL) based on the combination of a diffractive-based extended depth-of-focus (EDOF) pattern and a diffractive multifocal platform. Setting: Miranza COI Bilbao, Bilbao, Spain. Design: Prospective case series. Methods: 35 patients (51 to 84 years) with corneal astigmatism ranging from 0.75 to 2.19 diopters (D) undergoing bilateral cataract surgery with implantation of the Synergy Toric II IOL were evaluated during a 3-month follow-up. Visual acuity, refraction, defocus curve, and patient-reported outcomes with the Catquest-9SF questionnaire were analyzed. A vectorial analysis was used to analyze the accuracy of astigmatic correction. Results: Mean 3-month monocular postoperative uncorrected distance, intermediate (80 cm) and near (40 cm) visual acuities were 0.06 +/- 0.11 logMAR, 0.13 +/- 0.12 logMAR, and 0.13 +/- 0.09 logMAR, respectively. Mean monocular distance-corrected intermediate (80 cm) and near visual acuity (40 cm) were 0.11 +/- 0.12 logMAR and 0.10 +/- 0.10 logMAR, respectively. Mean binocular defocus curve showed visual acuities of 0.10 logMAR or better for defocus levels from +0.50 to -2.50 D. Residual cylinder was within +/- 0.50 D in 97.0% of eyes. The surgically induced astigmatism prediction error ranged between -0.49 D and 0.50 D, with a mean value of 0.04 +/- 0.16 D. Mean absolute IOL rotation was 3.79 +/- 2.94 degrees. Significant improvements were found in all Rasch-calibrated scores obtained with Catquest-9SF (P < .001). Conclusions: The implantation of the toric presbyopia-correcting IOL evaluated provides an efficacious astigmatic correction while providing a fully restoration of the visual function across different distances.
引用
收藏
页码:724 / 732
页数:9
相关论文
共 50 条
  • [21] Clinical Evaluation of Reading Performance in Refractive Lens Exchange With a Diffractive Continuous-Range-of-Vision Intraocular Lens
    Baur, Isabella D.
    Auffarth, Gerd U.
    Labuz, Grzegorz
    Stengele, Annette
    Hallak, Mustafa K.
    Khoramnia, Ramin
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 250 : 25 - 37
  • [22] Monovision LASIK Versus Presbyopia-Correcting IOLs: Comparison of Clinical and Patient-Reported Outcomes
    Schallhorn, Steven C.
    Teenan, David
    Venter, Jan A.
    Schallhorn, Julie M.
    Hettinger, Keith A.
    Hannan, Stephen J.
    Pelouskova, Martina
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (11) : 749 - +
  • [23] The role of presbyopia-correcting intraocular lenses after laser in situ keratomileusis
    Khor, Wei Boon
    Afshari, Natalie A.
    CURRENT OPINION IN OPHTHALMOLOGY, 2013, 24 (01) : 35 - 40
  • [24] Clinical outcomes of trifocal toric intraocular lenses
    Tana-Rivero, Pedro
    Rodriguez-Carrillo Maria, Dolores
    Tana-Sanz, Pedro
    Ruiz-Santos, Maria
    Tana-Sanz, Santiago
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2023, 33 (05) : 1773 - 1785
  • [25] Comparison of Two Presbyopia-Correcting Trifocal Intraocular Lenses: A Prospective Study
    Bayhan, Hasan Ali
    Tarci, Yelda Yildiz
    Bayhan, Seray Aslan
    Takmaz, Tamer
    Can, Izzet
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2024, 54 (02): : 63 - 68
  • [26] Functional outcomes after bilateral refractive lens exchange with a continuous-range-of-vision intraocular lens
    Khoramnia, Ramin
    Baur, Isabella D.
    Labuz, Grzegorz
    Koeppe, Maximilian K.
    Hallak, Mustafa K.
    Auffarth, Gerd U.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (10) : 1011 - 1017
  • [27] Visual performance after bilateral implantation of 2 new presbyopia-correcting intraocular lenses: Trifocal versus extended range of vision
    Monaco, Gaspare
    Gari, Mariangela
    Di Censo, Fabio
    Poscia, Andrea
    Ruggi, Giada
    Scialdone, Antonio
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (06) : 737 - 747
  • [28] Optical and Clinical Outcomes of an Extended Range of Vision Intraocular Lens
    Fernandez-Vega-Cueto, Luis
    Madrid-Costa, David
    Alfonso-Bartolozzi, Belen
    Vega, Fidel
    Millan, Maria S.
    Alfonso, Jose F.
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (03) : 168 - +
  • [29] Performance of presbyopia-correcting intraocular lenses in distance optical bench tests
    Maxwell, W. Andrew
    Lane, Stephen S.
    Zhou, Fan
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (01) : 166 - 171
  • [30] Recommendation for Presbyopia-Correcting Intraocular Lenses: A Delphi Consensus Statement by the ESASO Study Group
    Romano, Vito
    Madrid-Costa, David
    Alfonso, Jose F.
    Alio, Jorge
    Allan, Bruce
    Angunawela, Romesh
    Auffarth, Gerd
    Carones, Francesco
    Khoramnia, Ramin
    Moore, Johnny
    Nanavaty, Mayank A.
    Savini, Giacomo
    Pagano, Luca
    Romano, Mario R.
    Virgili, Gianni
    Fernandez-Vega-Cueto, Luis
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 253 : 169 - 180