A comparative dosimetric evaluation of dynamic conformal arc therapy and volumetric modulated arc therapy for lung stereotactic body radiotherapy

被引:0
|
作者
Thanh, Nguyen Van [1 ]
Tuong, Pham Nguyen [1 ]
Tai, Duong Thanh [2 ]
Loan, Truong Thi Hong [3 ,4 ,5 ]
Sandwall, Peter [6 ]
Bradley, David [7 ,8 ]
Chow, James C. L. [9 ,10 ]
机构
[1] Hue Cent Hosp, Oncol Ctr, Le Loi St, Hue City, Thua Thien Hue, Vietnam
[2] Nguyen Tat Thanh Univ, Fac Med, Dept Med Phys, 298-300A Nguyen Tat Thanh St,Ward 13,Dist 4, Ho Chi Minh City, Vietnam
[3] Univ Sci, Nucl Tech Lab, Ho Chi Minh City, Vietnam
[4] Univ Sci, Fac Phys & Engn Phys, Ho Chi Minh City, Vietnam
[5] Vietnam Natl Univ, Ho Chi Minh City, Vietnam
[6] OhioHealth, Mansfield Hosp, Dept Radiat Oncol, Mansfield, OH USA
[7] Sunway Univ, Appl Phys & Radiat Technol Grp, CCDCU, Pj 46150, Malaysia
[8] Univ Surrey, Sch Math & Phys, Guildford GU2 7XH, England
[9] Univ Toronto, Dept Radiat Oncol, Toronto, ON N5T 1P5, Canada
[10] Univ Hlth Network, Princess Margaret Canc Ctr, Radiat Med Program, Toronto, ON M5G 1X6, Canada
关键词
Lung stereotactic body radiotherapy (SBRT); Dynamic conformal arc therapy (DCAT); Volumetric modulated arc therapy (VMAT); Quality assurance (QA); RADIATION-THERAPY; QUALITY-ASSURANCE; PLANS;
D O I
10.1016/j.net.2024.11.013
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Purpose: This study assesses the viability of utilizing dynamic conformal arc therapy (DCAT) as an alternative to volumetric-modulated arc therapy (VMAT) in stereotactic body radiation therapy (SBRT) for lung cancer, with a focus on four-dimensional computed tomography (4DCT) in free-breathing conditions. Materials and methods: We selected four non-small cell lung cancer (NSCLC) patients who had previously undergone VMAT SBRT and re-planned their treatment using DCAT. We compared the DCAT and VMAT plans based on dose distribution, conformity index (CI), homogeneity index (HI), gradient index (GI), and total monitor units (MUs). Quality assurance (QA) assessments for both plans were conducted using the Octavius 4D system (PTW, Freiburg, Germany). Results: The results showed that CIPaddick was 0.80 f 0.06 and 0.79 f 0.04 (p-value >0.05), HI was 1.16 f 0.03 (p-value <0.05) and 1.07 f 0.02, GI was 3.91 f 0.05 and 3.40 f 0.05 (p-value <0.05), and MU was 1880.42 f 135.19 and 5020.82 f 188.03 for DCAT and VMAT, respectively (p-value <0.05). The average gamma passing rate exceeded 95 % with a 2 %/2 mm criteria. The dose distribution displayed remarkable similarity between DCAT and VMAT. Conclusion: The DCAT technique exhibits the capacity to deliver PTV dose distributions comparable to those achieved with VMAT, while significantly reducing treatment duration.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Volumetric modulated arc therapy treatment planning of thoracic vertebral metastases using stereotactic body radiotherapy
    Mallory, Matthew
    Pokhrel, Damodar
    Badkul, Rajeev
    Jiang, Hongyu
    Lominska, Christopher
    Wang, Fen
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (02): : 54 - 61
  • [22] Dosimetric Comparison of Intensity-Modulated Radiotherapy and Volumetric Arc Therapy for Rectal Cancer
    Oskeroglu Kaplan, Sedenay
    Akboru, Halil
    Sarali, Yunus
    Altin, Suleyman
    Unsal, Mustafa
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2019, 34 (02): : 59 - 65
  • [23] Dosimetric effect of collimator rotation on intensity modulated radiotherapy and volumetric modulated arc therapy for rectal cancer radiotherapy
    Abdulameer, Mohammed S.
    Pallathadka, Harikumar
    Menon, Soumya, V
    Rab, Safia Obaidur
    Hjazi, Ahmed
    Kaur, Mandeep
    Sivaprasad, G. V.
    Husseen, Beneen
    Al-Mualm, Mahmood
    Banaei, Amin
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2024, 32 (05) : 1331 - 1348
  • [24] Impact of plan parameters on the dosimetric accuracy of volumetric modulated arc therapy
    Masi, Laura
    Doro, Raffaela
    Favuzza, Virginia
    Cipressi, Samantha
    Livi, Lorenzo
    MEDICAL PHYSICS, 2013, 40 (07)
  • [25] Stereotactic radiotherapy for small and very small tumours (≤1 to ≤3 cc): evaluation of the influence of volumetric-modulated arc therapy in comparison to dynamic conformal arc therapy and 3D conformal radiotherapy as a function of flattened and unflattened beam models
    Mamballikalam, Gopinath
    Senthilkumar, S.
    Bos, R. C. Jaon
    Jayadevan, P. M.
    Basith, P. M. Ahamed
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2021, 20 (01) : 59 - 65
  • [26] Treatment of brain oligometastases with hypofractionated stereotactic radiotherapy utilising volumetric modulated arc therapy
    Croker, Jeremy
    Chua, Benjamin
    Bernard, Anne
    Allon, Maryse
    Foote, Matthew
    CLINICAL & EXPERIMENTAL METASTASIS, 2016, 33 (02) : 125 - 132
  • [27] Is there a dosimetric advantage of volumetric modulated arc therapy over intensity modulated radiotherapy in head and neck cancer?
    Buciuman, Nikolett
    Marcu, Loredana G.
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2022, 279 (11) : 5311 - 5321
  • [28] Interplay effect modeling in stereotactic body radiotherapy treatment of liver cancer using volumetric modulated arc therapy
    Thaper, Deepak
    Oinam, Arun S.
    Kamal, Rose
    Singh, Gaganpreet
    Handa, Bhumika
    Kumar, Vivek
    Yadav, Hanuman P.
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (01) : 123 - 134
  • [29] Improving Delivery Accuracy of Stereotactic Body Radiotherapy to a Moving Tumor Using Simplified Volumetric Modulated Arc Therapy
    Ko, Young Eun
    Cho, Byungchul
    Kim, Su Ssan
    Song, Si Yeol
    Choi, Eun Kyung
    Ahn, Seung Do
    Yi, Byongyong
    PLOS ONE, 2016, 11 (06):
  • [30] STEREOTACTIC RADIOTHERAPY OF INTRACRANIAL TUMORS: A COMPARISON OF INTENSITY-MODULATED RADIOTHERAPY AND DYNAMIC CONFORMAL ARC
    Wiggenraad, Ruud G. J.
    Petoukhova, Anna L.
    Versluis, Lia
    van Santvoort, Jan P. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (04): : 1018 - 1026