A comparative dosimetric evaluation of dynamic conformal arc therapy and volumetric modulated arc therapy for lung stereotactic body radiotherapy

被引:1
作者
Thanh, Nguyen Van [1 ]
Tuong, Pham Nguyen [1 ]
Tai, Duong Thanh [2 ]
Loan, Truong Thi Hong [3 ,4 ,5 ]
Sandwall, Peter [6 ]
Bradley, David [7 ,8 ]
Chow, James C. L. [9 ,10 ]
机构
[1] Hue Cent Hosp, Oncol Ctr, Le Loi St, Hue City, Thua Thien Hue, Vietnam
[2] Nguyen Tat Thanh Univ, Fac Med, Dept Med Phys, 298-300A Nguyen Tat Thanh St,Ward 13,Dist 4, Ho Chi Minh City, Vietnam
[3] Univ Sci, Nucl Tech Lab, Ho Chi Minh City, Vietnam
[4] Univ Sci, Fac Phys & Engn Phys, Ho Chi Minh City, Vietnam
[5] Vietnam Natl Univ, Ho Chi Minh City, Vietnam
[6] OhioHealth, Mansfield Hosp, Dept Radiat Oncol, Mansfield, OH USA
[7] Sunway Univ, Appl Phys & Radiat Technol Grp, CCDCU, Pj 46150, Malaysia
[8] Univ Surrey, Sch Math & Phys, Guildford GU2 7XH, England
[9] Univ Toronto, Dept Radiat Oncol, Toronto, ON N5T 1P5, Canada
[10] Univ Hlth Network, Princess Margaret Canc Ctr, Radiat Med Program, Toronto, ON M5G 1X6, Canada
关键词
Lung stereotactic body radiotherapy (SBRT); Dynamic conformal arc therapy (DCAT); Volumetric modulated arc therapy (VMAT); Quality assurance (QA); RADIATION-THERAPY; QUALITY-ASSURANCE; PLANS;
D O I
10.1016/j.net.2024.11.013
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Purpose: This study assesses the viability of utilizing dynamic conformal arc therapy (DCAT) as an alternative to volumetric-modulated arc therapy (VMAT) in stereotactic body radiation therapy (SBRT) for lung cancer, with a focus on four-dimensional computed tomography (4DCT) in free-breathing conditions. Materials and methods: We selected four non-small cell lung cancer (NSCLC) patients who had previously undergone VMAT SBRT and re-planned their treatment using DCAT. We compared the DCAT and VMAT plans based on dose distribution, conformity index (CI), homogeneity index (HI), gradient index (GI), and total monitor units (MUs). Quality assurance (QA) assessments for both plans were conducted using the Octavius 4D system (PTW, Freiburg, Germany). Results: The results showed that CIPaddick was 0.80 f 0.06 and 0.79 f 0.04 (p-value >0.05), HI was 1.16 f 0.03 (p-value <0.05) and 1.07 f 0.02, GI was 3.91 f 0.05 and 3.40 f 0.05 (p-value <0.05), and MU was 1880.42 f 135.19 and 5020.82 f 188.03 for DCAT and VMAT, respectively (p-value <0.05). The average gamma passing rate exceeded 95 % with a 2 %/2 mm criteria. The dose distribution displayed remarkable similarity between DCAT and VMAT. Conclusion: The DCAT technique exhibits the capacity to deliver PTV dose distributions comparable to those achieved with VMAT, while significantly reducing treatment duration.
引用
收藏
页数:6
相关论文
共 20 条
[1]   Stereotactic body radiation therapy: The report of AAPM Task Group 101 [J].
Benedict, Stanley H. ;
Yenice, Kamil M. ;
Followill, David ;
Galvin, James M. ;
Hinson, William ;
Kavanagh, Brian ;
Keall, Paul ;
Lovelock, Michael ;
Meeks, Sanford ;
Papiez, Lech ;
Purdie, Thomas ;
Sadagopan, Ramaswamy ;
Schell, Michael C. ;
Salter, Bill ;
Schlesinger, David J. ;
Shiu, Almon S. ;
Solberg, Timothy ;
Song, Danny Y. ;
Stieber, Volker ;
Timmerman, Robert ;
Tome, Wolfgang A. ;
Verellen, Dirk ;
Wang, Lu ;
Yin, Fang-Fang .
MEDICAL PHYSICS, 2010, 37 (08) :4078-4101
[2]   Dynamic conformal arcs for lung stereotactic body radiation therapy: A comparison with volumetric-modulated arc therapy [J].
Bokrantz, Rasmus ;
Wedenberg, Minna ;
Sandwall, Peter .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (01) :103-109
[3]   Quality assurance of the jaws only-intensity modulated radiation therapy plans for head-and-neck cancer [J].
Duong Thanh Tai ;
Nguyen Dong Son ;
Truong Thi Hong Loan ;
Anson, H. P. W. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 38 :148-152
[4]  
Durmus I.F., 2023, J. Cancer Res. Therapeut., DOI [10.4103/jcrt.JCRT_738_20, DOI 10.4103/JCRT.JCRT_738_20]
[5]   Dosimetric comparison of mDCAT and VMAT techniques according to 6MV-FFF and 10MV-FFF energies in patients with single adrenal metastasis [J].
Durmus, Ismail Faruk ;
Okumus, Ayse .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (05) :1023-1032
[6]  
Faruk Durmus Ismail, 2023, [PROGRESS in MEDICAL PHYSICS, 의학물리], V34, P41, DOI 10.14316/pmp.2023.34.4.41
[7]   Volumetric modulated arc therapy for delivery of hypofractionated stereotactic lung radiotherapy: A dosimetric and treatment efficiency analysis [J].
McGrath, Samuel D. ;
Matuszak, Martha M. ;
Yan, Di ;
Kestin, Larry L. ;
Martinez, Alvaro A. ;
Grills, Inga S. .
RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) :153-157
[8]   Clinical outcomes and lung toxicities after lung SABR using dynamic conformal arc therapy: a single-institution cohort study [J].
Mesny, Emmanuel ;
Ayadi, Myriam ;
Dupuis, Pauline ;
Beldjoudi, Guillaume ;
Tanguy, Ronan ;
Martel-Lafay, Isabelle .
RADIATION ONCOLOGY, 2023, 18 (01)
[9]   Which Is Better for Liver SBRT: Dosimetric Comparison Between DCAT and VMAT for Liver Tumors [J].
Moon, Young Min ;
Jeon, Wan ;
Yu, Tosol ;
Bae, Sang Il ;
Kim, Jin Young ;
Kang, Jin-Kyu ;
Choi, Chul Won .
FRONTIERS IN ONCOLOGY, 2020, 10
[10]   Stereotactic body radiotherapy improves the survival of patients with oligometastatic non-small cell lung cancer [J].
Ouyang, Wen ;
Yu, Jing ;
Nuerjiang, Shuake ;
Li, Zhijun ;
Wang, Dajiang ;
Wang, Xiaoyong ;
Zhang, Junhong ;
Xie, Conghua .
CANCER MEDICINE, 2019, 8 (10) :4605-4614